A new approach to improve the specificity of flow-mediated dilation for indicating endothelial function in cardiovascular research
The DOI matches its Crossref record; 11 of the 11 references it cites were found in a registry or an index.
Abstract
Flow-mediated dilation (FMD) is a noninvasive indicator of endothelial function and is routinely expressed as the percentage change in arterial diameter (FMD%) from a resting baseline (Dbase) to a postischemic peak (Dpeak). This expression is equivalent to the ratio of Dpeak/Dbase and is, therefore, dependent on important statistical assumptions, which have never been analysed in the context of FMD%. We aimed to investigate these assumptions, via a comparison of FMD between samples of children and adults, as well as to explore other approaches to scaling diameter change for Dbase. We found that FMD% did not scale accurately for interindividual differences in Dbase but, as expected, overestimated endothelial function for low Dbase and vice versa. We argue that this imprecise scaling of FMD% is predictable, not explained by physiology and is probably common. This problem is resolved by applying scaling principles, whereby the difference in diameter is the outcome and Dbase is a covariate in a logarithmic-linked generalized linear model. A specific allometric expression of FMD can be derived and we found this to be Dpeak/Dbase rather than a simple ratio in our particular dataset. We found that sample differences in endothelial function were inaccurate with FMD% versus our new allometric approach, and that FMD% misclassified participants into 'high' and 'low'cohorts, which has implications for prognostic-type studies. We conclude that the general use of FMD% could have led to biased comparisons of different conditions and/or populations in past studies. Our new approach to scaling FMD is flexible for different datasets and is not based on the current assumption that a percentage change is appropriate in all circumstances.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Non-invasive detection of endothelial dysfunction in children and adults at risk of atherosclerosis
Celermajer, D. S., Sorensen, K. E., Gooch, V. M., Spiegelhalter, D. J., Miller, O. I., Sullivan, I. D., Lloyd, J. K., & Deanfield, J. E. (1992) · The Lancet · doi:10.1016/0140-6736(92)93147-f · Cited by 4,742 · cited 5×
“[3], in which the FMD technique was described in detail, has been cited over 2500 times.”
BackgroundMethodInfluentialAssessment of flow-mediated dilation in humans: a methodological and physiological guideline
Thijssen, D. H. J., Black, M. A., Pyke, K. E., Padilla, J., Atkinson, G., Harris, R. A., Parker, B., Widlansky, M. E., Tschakovsky, M. E., & Green, D. J. (2011) · American Journal of Physiology-Heart and Circulatory Physiology · doi:10.1152/ajpheart.00471.2010 · Cited by 1,483 · cited 2×
“[3], researchers have strived to improve the sensitivity and specificity of FMD% for representing true differences in endothelial function between and within individuals [1].”
BackgroundSelf-citationYeboah, J., Crouse, J. R., Hsu, F.-C., Burke, G. L., & Herrington, D. M. (2007) · Circulation · doi:10.1161/circulationaha.106.678276 · Cited by 891
Pyke, K. E., & Tschakovsky, M. E. (2005) · The Journal of Physiology · doi:10.1113/jphysiol.2005.089755 · Cited by 614 · cited 1×
“divided by) the shear stimulus, which can also be measured during the FMD protocol [4].”
BackgroundVickers, A. J. (2001) · BMC Medical Research Methodology · doi:10.1186/1471-2288-1-6 · Cited by 559 · cited 2×
“TODbase In the context of randomized controlled trials, Vickers [10] has already shown that analysis of covariance (ANCOVA) is generally superior to a percentage change statistic.”
MethodPackard, G. C., & Boardman, T. J. (1999) · Comparative Biochemistry and Physiology Part A: Molecular & Integrative Physiology · doi:10.1016/s1095-6433(98)10170-8 · Cited by 439
Change from baseline and analysis of covariance revisited
Senn, S. (2006) · Statistics in Medicine · doi:10.1002/sim.2682 · Cited by 386 · cited 1×
“Important assumptions, such as ‘parallelism’ in ANCOVA should be checked, although Senn [12] has argued in the context of randomized-controlled trials that, even if such statistical assumptions are violated, ANCOVA is still superior to simple change summary statistics.”
BackgroundStatistical considerations regarding the use of ratios to adjust data.
Allison, D. B., Paultre, F., Goran, M. I., Poehlman, É. T., & Heymsfield, S. B. (1995) · PubMed · Cited by 339
Ratios as a size adjustment in morphometrics
Albrecht, G. H., Gelvin, B. R., & Hartman, S. E. (1993) · American Journal of Physical Anthropology · doi:10.1002/ajpa.1330910404 · Cited by 203 · cited 1×
“The influence of Dbase could be removed using an appropriate statistical model and the residuals from this model could be used as Dbase-adjusted predictors of cardiovascular events [13].”
MethodThe impact of baseline diameter on flow-mediated dilation differs in young and older humans
Thijssen, D. H. J., van Bemmel, M. M., Bullens, L. M., Dawson, E. A., Hopkins, N. D., Tinken, T. M., Black, M. A., Hopman, M. T. E., Cable, N. T., & GREEN, D. J. (2008) · American Journal of Physiology-Heart and Circulatory Physiology · doi:10.1152/ajpheart.00669.2008 · Cited by 81 · cited 1×
“[3] and others [8] have shown that FMD% is moderately and negatively correlated with baseline diameter so that individuals with smaller diameters of arteries showed the largest FMD response, and vice versa.”
Self-citation
Cited by
Thijssen, D. H. J., Bruno, R. M., van Mil, A. C. C. M., Holder, S. M., Faita, F., Greyling, A., Zock, P. L., Taddei, S., Deanfield, J. E., Luscher, T., et al. (2019) · European Heart Journal · doi:10.1093/eurheartj/ehz350 · Cited by 995
Self-citationIs Flow-Mediated Dilation Nitric Oxide Mediated?: A Meta-Analysis
Green, D. J., Dawson, E. A., Groenewoud, H. M. M., Jones, H., & Thijssen, D. H. J. (2014) · Hypertension · doi:10.1161/hypertensionaha.113.02044 · Cited by 360
Self-citationAllometric scaling of diameter change in the original flow-mediated dilation protocol
Atkinson, G., & Batterham, A. M. (2013) · Atherosclerosis · doi:10.1016/j.atherosclerosis.2012.11.027 · Cited by 213
Self-citationEffects of acute exercise on flow-mediated dilatation in healthy humans
Dawson, E. A., Green, D. J., Timothy Cable, N., & Thijssen, D. H. J. (2013) · Journal of Applied Physiology · doi:10.1152/japplphysiol.00450.2013 · Cited by 205
“It has been suggested that the changes in baseline diameter that result from acute exercise may be a limitation for using FMD to evaluate endothelial function immediately postexercise (3, 65).”
MethodSelf-citationSawyer, B. J., Tucker, W. J., Bhammar, D. M., Ryder, J. R., Sweazea, K. L., & Gaesser, G. A. (2016) · Journal of Applied Physiology · doi:10.1152/japplphysiol.00024.2016 · Cited by 178
Metadata
- Authors
- Atkinson, G., Batterham, A. M., Thijssen, D. H. J., & Green, D. J.
- Venue
- Journal of Hypertension
- Published
- 2013-02
- Volume
- 31
- Issue
- 2
- Pages
- 287-291
- ISSN
- 0263-6352 (ISSN-L)
- OpenAlex
- W1982490079
- Cited by
- 200
- References
- 11
- FWCI
- 12.09
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: A new approach to improve the specificity of flow-mediated dilation for indicating endothelial function in cardiovascular research. https://app.cochat.ai/papers/10.1097/hjh.0b013e32835b8164
- The paper
- Atkinson, G., Batterham, A. M., Thijssen, D. H. J., & Green, D. J. (2013). A new approach to improve the specificity of flow-mediated dilation for indicating endothelial function in cardiovascular research. Journal of Hypertension. https://doi.org/10.1097/hjh.0b013e32835b8164
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.