CoChat

IDENTIFICATION OF FLUID ON OPTICAL COHERENCE TOMOGRAPHY BY TREATING OPHTHALMOLOGISTS VERSUS A READING CENTER IN THE COMPARISON OF AGE-RELATED MACULAR DEGENERATION TREATMENTS TRIALS

Open access
Toth, Cynthia A., Decroos, Francis Char, Ying, Gui-Shuang, Stinnett, Sandra S., Heydary, Cynthia S., Burns, Russell, Maguire, Maureen, Martin, Daniel, Jaffe, Glenn J. · 2015 · Retina
Cited by 66

The DOI matches its Crossref record; 8 of the 8 references it cites were found in a registry or an index.

Abstract

PURPOSE: To examine treatment decisions by ophthalmologists versus reading center fluid identification from optical coherence tomography in Comparison of Age-Related Macular Degeneration Treatments Trials (CATT). METHODS: Fluid in 6,210 optical coherence tomography scans (598 patients) in "as needed treatment" arm of CATT Year 1 was compared with ophthalmologist's treatment: positive fluid agreement (PFA, fluid+, treatment+) and positive fluid discrepancy (PFD, fluid+, treatment-), negative fluid agreement (fluid-, treatment-) and negative fluid discrepancy (fluid-, treatment+). For PFDs, fluid location and visual acuity were characterized. RESULTS: Treatment and reading center fluid determination agreed in 72.1% (53.0% PFA, 19.1% negative fluid agreement) and disagreed in 27.9% (25.7% PFD, 2.2% negative fluid discrepancy) of visits, with no discrepancies for 20.9% of patients. Compared with PFA, PFD occurred more commonly with lower total foveal thickness (mean ± SD: 265 ± 103 PFD, 366 ± 151 μm PFA), presence of intraretinal fluid only, smaller fluid areas (PFA areas greater than twice those of PFD, P < 0.001), and greater decrease in retinal and lesion thickness. Mean acuities before, at, and after PFD were 65.8, 66.9, and 66.3 letters. CONCLUSION: Treatment decisions by ophthalmologists matched reading center fluid determination in the majority of visits. More pronounced response to treatment and smaller foci of fluid likely contributed to PFD. Positive fluid discrepancy did not have substantial impact on subsequent visual acuity.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1097/iae.0000000000000483

Cites

8 of 8 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 8 references

Cited by

See all 66

Metadata

Authors
Toth, C. A., Decroos, F. C., Ying, G.-S., Stinnett, S. S., Heydary, C. S., Burns, R., Maguire, M., Martin, D., & Jaffe, G. J.
Venue
Retina
Published
2015-07
Volume
35
Issue
7
Pages
1303-1314
ISSN
0275-004X (ISSN-L)
OpenAlex
W2330952183
Cited by
66
References
8
FWCI
2.03
Type
journal article
Language
en
Open access
green

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: IDENTIFICATION OF FLUID ON OPTICAL COHERENCE TOMOGRAPHY BY TREATING OPHTHALMOLOGISTS VERSUS A READING CENTER IN THE COMPARISON OF AGE-RELATED MACULAR DEGENERATION TREATMENTS TRIALS. https://app.cochat.ai/papers/10.1097/iae.0000000000000483
The paper
Toth, C. A., Decroos, F. C., Ying, G.-S., Stinnett, S. S., Heydary, C. S., Burns, R., Maguire, M., Martin, D., & Jaffe, G. J. (2015). IDENTIFICATION OF FLUID ON OPTICAL COHERENCE TOMOGRAPHY BY TREATING OPHTHALMOLOGISTS VERSUS A READING CENTER IN THE COMPARISON OF AGE-RELATED MACULAR DEGENERATION TREATMENTS TRIALS. Retina. https://doi.org/10.1097/iae.0000000000000483

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.