Feasibility study of intraocular robotic surgery with the da Vinci surgical system
Abstract
In Brief Purpose: To assess the feasibility of performing intraocular robotic surgery with the da Vinci Surgical System (Intuitive Surgical, Sunnyvale, CA). Methods: Using modified robotic instruments, 25-gauge pars plana vitrectomy, intraocular foreign body removal, and anterior capsulorhexis were performed with the da Vinci system on porcine eyes. We assessed the surgical system’s ability to provide the control, dexterity, maneuverability, and visualization necessary for intraocular surgery. Results: Control of the robotic wristlike instruments allowed for full range of movement. The dexterity of the robotic arms was excellent, with steady instrument motion. Controlling the robotic arms was not as intuitive as moving the wrist. A high stable point of rotation induced motion-related stress at the site of instrument insertion. Visualization of the external operative field during intraocular procedures required camera realignment, and absent retroillumination made anterior segment surgery hard to perform. Conclusions: The da Vinci Surgical System provided adequate dexterity for performing delicate intraocular manipulations. In the current design, the kinematics of the robotic arms was found to be insufficient for standard intraocular surgery. The system’s endoscope did not did not yield the same detail acquired by an ophthalmic microscope. The feasibility of performing intraocular robotic surgery with the da Vinci Surgical System (Intuitive Surgical, Sunnyvale, CA) was assessed. Using modified robotic instruments, 25-gauge pars plana vitrectomy, intraocular foreign body removal, and anterior capsulorhexis were performed. We found that the da Vinci robot has adequate dexterity to perform delicate intraocular manipulations.
Integrity signals
Registry
Cites
Statistics
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
Adapting existing robotic systems to ophthalmology is fraught with problems.
“Adapting existing robotic systems to ophthalmology is therefore fraught with problems (70).”
From Subretinal therapy: technological solutions to surgical and immunological challenges (2022) · cites this paper as [70]
Cites
Transcontinental Robot-Assisted Remote Telesurgery: Feasibility and Potential Applications
Marescaux, J., Leroy, J., Rubino, F., Smith, M. L., Vix, M., Simone, M. D., & Mutter, D. (2002) · Annals of Surgery · doi:10.1097/00000658-200204000-00005 · Cited by 611 · see citing works
A Steady-Hand Robotic System for Microsurgical Augmentation
Taylor, R., Jensen, P., Whitcomb, L., Barnes, A., Kumar, R., Stoianovici, D., Gupta, P., Wang, Z., Dejuan, E., & Kavoussi, L. (1999) · The International Journal of Robotics Research · doi:10.1177/02783649922067807 · Cited by 528 · see citing works
Dexterity enhancement with robotic surgery
Moorthy, K., Munz, Y., Dosis, A., Hernández, J. D., Martin, S., Bello, F., Rockall, T., & Darzi, A. W. (2004) · Surgical Endoscopy · doi:10.1007/s00464-003-8922-2 · Cited by 328 · see citing works
KAUL, S. A., Laungani, R. G., Sarle, R. C., et al. (2006) · European Urology · doi:10.1016/j.eururo.2006.06.002 · Cited by 203 · see citing works
The Pitfalls of Laparoscopic Surgery: Challenges for Robotics and Telerobotic Surgery
Ballantyne, G. H. (2002) · Surgical Laparoscopy Endoscopy & Percutaneous Techniques · doi:10.1097/00129689-200202000-00001 · Cited by 176 · see citing works
Surgical robotics: Impact of motion scaling on task performance
Prasad, S. M., Prasad, S. M., Maniar, H. S., Chu, C., Schuessler, R. B., & Damiano, R. J. (2004) · Journal of the American College of Surgeons · doi:10.1016/j.jamcollsurg.2004.08.027 · Cited by 140 · see citing works
The Impact of Minimally Invasive Surgical Techniques
Darzi, A. W., & Munz, Y. (2004) · Annual Review of Medicine · doi:10.1146/annurev.med.55.091902.105248 · Cited by 140 · see citing works
The da Vinci robotic system for general surgical applications: a critical interim appraisal
Bodner, J., Augustin, F., Wykypiel, H., et al. (2005) · Swiss Medical Weekly · doi:10.4414/smw.2005.11022 · Cited by 109 · see citing works
Twenty-first century surgery using twenty-first century technology: Surgical robotics
Marohn, M. R., & Hanly, C. E. J. (2004) · Current Surgery · doi:10.1016/j.cursur.2004.03.009 · Cited by 108 · see citing works
Total laparoscopic hysterectomy utilizing a robotic surgical system.
Beste, T. M., Nelson, K. H., & Daucher, J. A. (2005) · PubMed · Cited by 106 · see citing works
Integrated Coronary Revascularization
Katz, M., Praet, F. V., de Cannière, D., et al. (2006) · Circulation · doi:10.1161/circulationaha.105.001537 · Cited by 102 · see citing works
Optimal planning for minimally invasive surgical robots
Adhami, L., & Coste-Manière, È. (2003) · IEEE Transactions on Robotics and Automation · doi:10.1109/tra.2003.817061 · Cited by 88 · see citing works
Tsirbas, A., Mango, C. W., & Dutson, E. (2006) · British Journal of Ophthalmology · doi:10.1136/bjo.2006.096040 · Cited by 66 · see citing works
Self-citationEmerging role of robotics in urology
Kumar, R., & Hemal, A. (2005) · Journal of Minimal Access Surgery · doi:10.4103/0972-9941.19268 · Cited by 39 · see citing works
Robotics in Laparoscopic Surgery: Current Status and Future Perspectives
Broeders, I. A. M. J., & Ruurda, J. P. H. (2002) · Scandinavian Journal of Gastroenterology · doi:10.1080/003655202320621508 · Cited by 25 · see citing works
McClure, R. S., Kiaii, B. B., Novick, R. J., et al. (2006) · PubMed · Cited by 22 · see citing works
Smith, W. D., Berguer, R., & Rosser, J. C. (2003) · PubMed · Cited by 21 · see citing works
COMING FULL CIRCLE IN ROBOTIC UROLOGY
Dasgupta, P., Challacombe, B. J., Murphy, D. G., et al. (2006) · British Journal of Urology · doi:10.1111/j.1464-410x.2006.06242.x · Cited by 15 · see citing works
Robotic cardiovascular surgery
Kypson, A. P., & Chitwood, W. R. (2006) · Expert Review of Medical Devices · doi:10.1586/17434440.3.3.335 · Cited by 15 · see citing works
Robot vision-advanced techniques and the way ahead
Forrest, A. K. (1986) · Physics in Technology · doi:10.1088/0305-4624/17/3/i01 · Cited by 1 · see citing works
Flagged first, then by citations
Cited by
Sorted by citations
Micron: An Actively Stabilized Handheld Tool for Microsurgery
MacLachlan, R. A., Becker, B. C., Tabares, J. C., Podnar, G. W., Lobes, L. A., & Riviere, C. N. (2012) · IEEE Transactions on Robotics · doi:10.1109/tro.2011.2169634 · Cited by 270 · see citing works
Subretinal therapy: technological solutions to surgical and immunological challenges
Ladha, R., Caspers, L. E., Willermain, F., & de Smet, M. D. (2022) · Frontiers in Medicine · doi:10.3389/fmed.2022.846782 · Cited by 54 · see citing works
Da Vinci Xi robot-assisted penetrating keratoplasty
Chammas, J., Sauer, A., Pizzuto, J., Pouthier, F., Gaucher, D., Marescaux, J., Mutter, D., & Bourcier, T. (2017) · Translational Vision Science & Technology · doi:10.1167/tvst.6.3.21 · Cited by 52 · see citing works
- Authors
- BOURLA, D. H., HUBSCHMAN, J. P., CULJAT, M., TSIRBAS, A., GUPTA, A., & SCHWARTZ, S. D.
- Affiliations
- University of California, Los Angeles (US)
- Corresponding author
- BOURLA, DAN H.
- HUBSCHMAN, JEAN PIERRE
- TSIRBAS, ANGELO
- GUPTA, ANURAG
- SCHWARTZ, STEVEN D.
- Venue
- Retina
- Published
- 2008-01
- Volume
- 28
- Issue
- 1
- Pages
- 154-158
- ISSN
- 0275-004X (ISSN-L)
- OpenAlex
- W2024793882
- Cited by
- 106
- References
- 20
- Citations by year
- 2026: 5 · 2025: 7 · 2024: 3 · 2023: 4 · 2022: 5 · 2021: 7 · 2020: 6 · 2019: 9 · 2018: 5 · 2017: 10 · 2016: 4 · 2015: 10 · 2014: 4 · 2013: 8 · 2012: 5
- FWCI
- 3.33
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- Retina (publishedVersion)
- PubMed (publishedVersion)
- Topics
- Health Sciences › Medicine › Radiology, Nuclear Medicine and Imaging › Retinal and Macular Surgery
- Health Sciences › Medicine › Ophthalmology › Intraocular Surgery and Lenses
- Health Sciences › Medicine › Surgery › Minimally Invasive Surgical Techniques
- Keywords
- da Vinci surgical system, pars plana vitrectomy, intraocular foreign body removal, anterior capsulorhexis, robotic dexterity, robotic arm kinematics, porcine eyes, ophthalmic microsurgery
- MeSH terms
- Animals, Biomechanical Phenomena, Eye Foreign Bodies, Feasibility Studies, Robotics, Swine, Vitrectomy, Capsulorhexis, Surgery, Computer-Assisted
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review