Electroretinography in glaucoma diagnosis
Open accessThe DOI matches its Crossref record; 72 of the 72 references it cites were found in a registry or an index.
Abstract
PURPOSE OF REVIEW: Electrophysiological measures of vision function have for decades generated interest among glaucoma researchers and clinicians alike because of their potential to help elucidate pathophysiological processes and sequence of glaucomatous damage, as well as to offer a potential complementary metric of function that might be more sensitive than standard automated perimetry. The purpose of this article is to review the recent literature to provide an update on the role of the electroretinogram (ERG) in glaucoma diagnosis. RECENT FINDINGS: The pattern reversal ERG (PERG) and the photopic negative response (PhNR) of the cone-driven full-field, focal or multifocal ERG provide objective measures of retinal ganglion cell function and are all sensitive to glaucomatous damage. Recent studies demonstrate that a reduced PERG amplitude is predictive of subsequent visual field conversion (from normal to glaucomatous) and an increased rate of progressive retinal nerve fiber layer thinning in suspect eyes, indicating a potential role for PERG in risk stratification. Converging evidence indicates that some portion of PERG and PhNR abnormality represents a reversible aspect of dysfunction in glaucoma. SUMMARY: PERG and PhNR responses obtained from the central macula are capable of detecting early-stage, reversible glaucomatous dysfunction.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
The field topography of ERG components in man—I. The photopic luminance response
Sutter, E. E., & Tran, D. (1992) · Vision Research · doi:10.1016/0042-6989(92)90235-b · Cited by 946
Oscillatory potentials in the retina: what do they reveal
Wachtmeister, L. (1998) · Progress in Retinal and Eye Research · doi:10.1016/s1350-9462(98)00006-8 · Cited by 529 · cited 1×
“The OPs are thought to arise within the inner plexiform layer as a consequence of inhibitory feedback loops involving primarily amacrine cells [2].”
BackgroundAssessing retinal function with the multifocal technique
Hood, D. C. (2000) · Progress in Retinal and Eye Research · doi:10.1016/s1350-9462(00)00013-6 · Cited by 481 · cited 2×
“There are additional types of ERG recordings based on alternative stimulus and recording paradigms rather than full-field flashes such as the well known pattern reversal ERG (PERG) [22] and multifocal ERG (mfERG) [23], which can also be obtained in a routine clinical setting and offer meaningful objective measurements…”
BackgroundThe photopic negative response of the macaque electroretinogram: reduction by experimental glaucoma.
Viswanáthan, S., Frishman, L. J., Robson, J. G., Harwerth, R. S., & Smith, E. L. (1999) · PubMed · Cited by 417
Sieving, P. A., Murayama, K., & Naarendorp, F. (1994) · Visual Neuroscience · doi:10.1017/s0952523800002431 · Cited by 388
The topography of visual evoked response properties across the visual field
Baseler, H. A., Sutter, E. E., Klein, S. A., & Carney, T. (1994) · Electroencephalography and Clinical Neurophysiology · doi:10.1016/0013-4694(94)90114-7 · Cited by 320
The Scotopic Threshold Response of the Dark‐Adapted Electroretinogram of the Mouse
Saszik, S. M., Robson, J. G., & Frishman, L. J. (2002) · The Journal of Physiology · doi:10.1113/jphysiol.2002.019703 · Cited by 295
The photopic negative response of the flash electroretinogram in primary open angle glaucoma.
Viswanáthan, S., Frishman, L. J., Robson, J. G., & Walters, J. W. (2001) · PubMed · Cited by 273
Viswanáthan, S., Frishman, L. J., & Robson, J. G. (2000) · PubMed · Cited by 255
Multifocal VEP and ganglion cell damage: applications and limitations for the study of glaucoma
Hood, D. (2003) · Progress in Retinal and Eye Research · doi:10.1016/s1350-9462(02)00061-7 · Cited by 245 · cited 1×
“Thorough reviews of the clinical applications of multifocal ERG and visual evoked response (VER) were published by Hood in 2000 [23] and 2003 [47], respectively.”
BackgroundGanglion cell contributions to the rat full‐field electroretinogram
Bui, B. V., & Fortune, B. (2004) · The Journal of Physiology · doi:10.1113/jphysiol.2003.052738 · Cited by 239
Self-citationDissecting the dark-adapted electroretinogram
Robson, J. G., & Frishman, L. J. (1998) · Documenta Ophthalmologica · doi:10.1023/a:1001891904176 · Cited by 217 · cited 1×
“Thus, the ERG is an important diagnostic tool capable of identifying the origin of vision loss in terms of specific retinal neuronal cell type and physiological mechanism [6,7].”
MethodSwelling and Loss of Photoreceptors in Chronic Human and Experimental Glaucomas
Nork, T. M. (2000) · Archives of Ophthalmology · doi:10.1001/archopht.118.2.235 · Cited by 212
The Fast m-Transform: A Fast Computation of Cross-Correlations with Binary m-Sequences
Sutter, E. E. (1991) · SIAM Journal on Computing · doi:10.1137/0220043 · Cited by 210
Klistorner, A. I., Graham, S. L., Grigg, J., & Billson, F. A. (1998) · PubMed · Cited by 192
Electrophysiological assessment of retinal ganglion cell function
Porciatti, V. (2015) · Experimental Eye Research · doi:10.1016/j.exer.2015.05.008 · Cited by 191
Scotopic threshold response of proximal retina in cat
Sieving, P. A., Frishman, L. J., & Steinberg, R. H. (1986) · Journal of Neurophysiology · doi:10.1152/jn.1986.56.4.1049 · Cited by 187 · cited 1×
“The scotopic threshold response (STR), for example, can be recorded under deep dark adaptation for stimulus flashes that are 2 log units dimmer than the scotopic B-wave ‘threshold’ observed under typical clinical conditions [14,15].”
BackgroundFrishman, L. J., Shen, F., Du, L. Z., Robson, J. G., Harwerth, R. S., Smith, E. L., Carter‐Dawson, L. D., & Crawford, M. L. J. (1996) · PubMed · Cited by 187
The optic nerve head component of the human ERG
Sutter, E. E., & Bearse, M. A. (1999) · Vision Research · doi:10.1016/s0042-6989(98)00161-8 · Cited by 171 · cited 1×
“thought to represent an optic nerve head component [52,53] hold great promise for evaluation of glaucoma, but remain extremely challenging to extract and quantify.”
BackgroundImaging visual function with the multifocal m-sequence technique
Sutter, E. E. (2001) · Vision Research · doi:10.1016/s0042-6989(01)00078-5 · Cited by 158
Update on the Pattern Electroretinogram in Glaucoma
Bach, M., & Hoffmann, M. B. (2008) · Optometry and Vision Science · doi:10.1097/opx.0b013e318177ebf3 · Cited by 157 · cited 1×
“There are additional types of ERG recordings based on alternative stimulus and recording paradigms rather than full-field flashes such as the well known pattern reversal ERG (PERG) [22] and multifocal ERG (mfERG) [23], which can also be obtained in a routine clinical setting and offer meaningful objective measurements…”
BackgroundBanitt, M. R., Ventura, L. M., Feuer, W. J., Savatovsky, E. J., Luna, G., Shif, O. A., Bosse, B., & Porciatti, V. (2013) · Investigative Ophthalmology & Visual Science · doi:10.1167/iovs.12-11026 · Cited by 131 · cited 5×
“[28] concluded that a glaucoma suspect with a severely reduced PERG indicates a need for ‘closer monitoring or treatment as he or she will have a higher rate of RNFL thinning’.”
BackgroundInfluentialChoi, S. S., Zawadzki, R. J., Lim, M. C., Brandt, J. D., Keltner, J. L., Doble, N., & Werner, J. S. (2011) · British Journal of Ophthalmology · doi:10.1136/bjo.2010.183756 · Cited by 127
Photopic Negative Response versus Pattern Electroretinogram in Early Glaucoma
Preiser, D., Lagrèze, W. A., Bach, M., & Poloschek, C. M. (2013) · Investigative Ophthalmology & Visual Science · doi:10.1167/iovs.12-11201 · Cited by 123 · cited 1×
“The third recently published study we chose to consider here was a direct comparison of PERG and PhNR diagnostic utility by Preiser and colleagues [36].”
BackgroundAssessment of early retinal changes in diabetes using a new multifocal ERG protocol
Shimada, Y. (2001) · British Journal of Ophthalmology · doi:10.1136/bjo.85.4.414 · Cited by 116 · cited 1×
“75 Hz) may enhance the optic nerve head component [54,55], but this is still difficult to extract and quantify in all healthy eyes.”
BackgroundThe rod-driven a-wave of the dark-adapted mammalian electroretinogram
Robson, J. G., & Frishman, L. J. (2013) · Progress in Retinal and Eye Research · doi:10.1016/j.preteyeres.2013.12.003 · Cited by 115 · cited 1×
“Thus, the ERG is an important diagnostic tool capable of identifying the origin of vision loss in terms of specific retinal neuronal cell type and physiological mechanism [6,7].”
MethodAn attempt to detect glaucomatous damage to the inner retina with the multifocal ERG.
Hood, D. C., Greenstein, V. C., Holopigian, K., Bauer, R., Firoz, B., Liebmann, J. M., Odel, J. G., & Ritch, R. H. (2000) · PubMed · Cited by 110
Rangaswamy, N. V., Shirato, S., Kaneko, M., Digby, B. I., Robson, J. G., & Frishman, L. J. (2007) · Investigative Ophthalmology & Visual Science · doi:10.1167/iovs.07-0218 · Cited by 105
Fortune, B. A., Bearse, M. A., Cioffi, G. A., & Johnson, C. A. (2002) · PubMed · Cited by 103
Self-citationElectrophysiological Approaches for Early Detection of Glaucoma
Bach, M. (2001) · European Journal of Ophthalmology · doi:10.1177/112067210101102s05 · Cited by 103 · cited 1×
“does not reflect the responses of retinal ganglion cells (RGCs), which are the primary neuron affected by glaucoma [8,9].”
BackgroundPattern Electroretinogram in Glaucoma Suspects: New Findings from a Longitudinal Study
Bode, S. F. N., Jehle, T., & Bach, M. (2011) · Investigative Ophthalmology & Visual Science · doi:10.1167/iovs.10-6381 · Cited by 101 · cited 4×
“[29] was that the predictive capacity of PERG for eventual conversion from normal to glaucomatous visual field damage ‘was roughly constant from conversion to 4 years before conversion, fitting with the view that PERG changes occurearly and then saturate, thus rendering the PERG a poor biomarker for monitoring advance…”
BackgroundResultInfluentialGraham, S. L. (2005) · Archives of Ophthalmology · doi:10.1001/archopht.123.6.729 · Cited by 98
Rangaswamy, N. V., Hood, D. C., & Frishman, L. J. (2003) · Investigative Ophthalmology & Visual Science · doi:10.1167/iovs.03-0009 · Cited by 96
Pattern electroretinogram in glaucoma
Ventura, L. M., & Porciatti, V. (2006) · Current Opinion in Ophthalmology · doi:10.1097/01.icu.0000193082.44938.3c · Cited by 92
Clinical Applications of the Photopic Negative Response to Optic Nerve and Retinal Diseases
Machida, S. (2012) · Journal of Ophthalmology · doi:10.1155/2012/397178 · Cited by 88 · cited 8×
“The PhNR has thus proven to be an effective objective clinical diagnostic test for assessment of RGC function in optic neuropathies, including glaucoma (for excellent recent reviews, see Machida [21] and Bach and Poloschek [9]).”
BackgroundInfluentialWerner, J. S., Keltner, J. L., Zawadzki, R. J., & Choi, S. S. (2011) · Eye · doi:10.1038/eye.2010.218 · Cited by 84
Effects of experimental glaucoma in macaques on the multifocal ERG
Frishman, L. J., Saszik, S. M., Harwerth, R. S., Viswanáthan, S., Li, Y., Smith, E. L., Robson, J. G., & Barnes, G. (2000) · Documenta Ophthalmologica · doi:10.1023/a:1002735804029 · Cited by 82
Reversal of Retinal Ganglion Cell Dysfunction after Surgical Reduction of Intraocular Pressure
Sehi, M., Grewal, D. S., Goodkin, M. L., & Greenfield, D. S. (2010) · Ophthalmology · doi:10.1016/j.ophtha.2010.08.049 · Cited by 79 · cited 1×
“They also discussed how their results using the PhNR were similar to earlier reports of improved PERG amplitude after IOP lowering [39,40].”
ResultFortune, B. A., Cull, G. A., & Burgoyne, C. F. (2008) · Investigative Ophthalmology & Visual Science · doi:10.1167/iovs.08-2255 · Cited by 77
Self-citationElectrophysiology and glaucoma: current status and future challenges
Bach, M., & Poloschek, C. M. (2013) · Cell and Tissue Research · doi:10.1007/s00441-013-1598-6 · Cited by 75 · cited 5×
“The PhNR has thus proven to be an effective objective clinical diagnostic test for assessment of RGC function in optic neuropathies, including glaucoma (for excellent recent reviews, see Machida [21] and Bach and Poloschek [9]).”
BackgroundInfluentialEffect of Experimental Glaucoma in Primates on Oscillatory Potentials of the Slow-Sequence mfERG
Rangaswamy, N. V., Zhou, W., Harwerth, R. S., & Frishman, L. J. (2006) · Investigative Ophthalmology & Visual Science · doi:10.1167/iovs.05-1051 · Cited by 70
Fortune, B. A., Demirel, S., Zhang, X., Hood, D. C., Patterson, E., Jamil, A. L., Mansberger, S. L., Cioffi, G. A., & Johnson, C. A. (2007) · Investigative Ophthalmology & Visual Science · doi:10.1167/iovs.06-0561 · Cited by 68
Self-citationMortlock, K. E., Binns, A. M., Aldebasi, Y. H., & North, R. V. (2010) · Documenta Ophthalmologica · doi:10.1007/s10633-010-9239-9 · Cited by 62
Fortune, B. A., Cull, G. A., Reynaud, J. F., Wang, L., & Burgoyne, C. F. (2015) · Investigative Ophthalmology & Visual Science · doi:10.1167/iovs.15-16548 · Cited by 59
Self-citationNiyadurupola, N., Luu, C. D., Nguyen, D. Q., Geddes, K., Tan, G. X. V., Wong, C. C. W., Tran, T. M., Coote, M., & Crowston, J. G. (2013) · Investigative Ophthalmology & Visual Science · doi:10.1167/iovs.12-10869 · Cited by 57 · cited 2×
“First is the careful study by Niyadurupola and colleagues [38], which provides a compelling demonstration of improvement in the PhNR amplitude within 1–2 months of intraocular pressure (IOP) lowering by standard clinical therapy.”
BackgroundMultifocal Pattern Electroretinogram does not demonstrate localised field defects in glaucoma
Klistorner, A. I., Graham, S. L., & Martins, A. (2000) · Documenta Ophthalmologica · doi:10.1023/a:1002772520539 · Cited by 55 · cited 1×
“However, unfortunately results to date reveal only a general amplitude reduction centrally with little or no topographic relationship to even advanced visual field loss [49,70,71].”
BackgroundThe optic nerve head component of the monkey's (Macaca mulatta) multifocal electroretinogram (mERG)
Hood, D. C., Bearse, M. A., Sutter, E. E., Viswanáthan, S., & Frishman, L. J. (2001) · Vision Research · doi:10.1016/s0042-6989(01)00010-4 · Cited by 55
Idiopathic Bilateral Optic Atrophy in the Rhesus Macaque
Fortune, B. A., Wang, L., Bui, B. V., Burgoyne, C. F., & Cioffi, G. A. (2005) · Investigative Ophthalmology & Visual Science · doi:10.1167/iovs.04-1160 · Cited by 54
Self-citationElectrophysiologic Assessment of Photoreceptor Function in Patients With Primary Open-angle Glaucoma
Holopigian, K., Greenstein, V. C., Seiple, W., Hood, D. C., & Ritch, R. H. (2000) · Journal of Glaucoma · doi:10.1097/00061198-200004000-00006 · Cited by 51 · cited 1×
“[13]; for a review of more recent studies on outer retinal changes in glaucoma, see Wilsey et al.”
BackgroundThe multifocal pattern electroretinogram in glaucoma
Stiefelmeyer, S., Neubauer, A. S., Berninger, T. A., Arden, G. B., & Rudolph, G. (2003) · Vision Research · doi:10.1016/j.visres.2003.08.012 · Cited by 50 · cited 1×
“However, unfortunately results to date reveal only a general amplitude reduction centrally with little or no topographic relationship to even advanced visual field loss [49,70,71].”
BackgroundThe Test–Retest Reliability of the Photopic Negative Response (PhNR)
Tang, J. J., Edwards, T. L., Crowston, J. G., & Sarossy, M. (2014) · Translational Vision Science & Technology · doi:10.1167/tvst.3.6.1 · Cited by 46
Ventura, L. M., Feuer, W. J., & Porciatti, V. (2012) · Investigative Ophthalmology & Visual Science · doi:10.1167/iovs.11-8525 · Cited by 44 · cited 1×
“They also discussed how their results using the PhNR were similar to earlier reports of improved PERG amplitude after IOP lowering [39,40].”
ResultBui, B. V., Batcha, A. H., Fletcher, E. L., Wong, V. H. Y., & Fortune, B. A. (2013) · PLoS ONE · doi:10.1371/journal.pone.0070513 · Cited by 44
Self-citationPalmowski-Wolfe, A. M., Allgayer, R., & Heinemann-Vemaleken, B. (2000) · Documenta Ophthalmologica · doi:10.1023/a:1002710707763 · Cited by 43
Fortune, B. A., Bui, B. V., Cull, G. A., Wang, L., & Cioffi, G. A. (2003) · Experimental Eye Research · doi:10.1016/j.exer.2003.09.013 · Cited by 41
Self-citationFortune, B. A., Wang, L., Bui, B. V., Cull, G. A., Dong, J., & Cioffi, G. A. (2003) · Investigative Ophthalmology & Visual Science · doi:10.1167/iovs.03-0200 · Cited by 41
Self-citationOn- and off-response ERGs elicited by sawtooth stimuli in normal subjects and glaucoma patients
Pangeni, G., Lämmer, R., Tornow, R. P., Horn, F. K., & Kremers, J. (2012) · Documenta Ophthalmologica · doi:10.1007/s10633-012-9323-4 · Cited by 40 · cited 1×
“These opposing contributions can be teased apart by extending the duration of the stimulus or by using ‘saw-tooth’ periodic stimulation [4,5].”
BackgroundFortune, B. A., Johnson, C. A., & Cioffi, G. A. (2001) · Optometry and Vision Science · doi:10.1097/00006324-200104000-00009 · Cited by 39
Self-citationAlterations of Photopic Negative Response of Multifocal Electroretinogram in Patients with Glaucoma
Kaneko, M., Machida, S., Hoshi, Y., & Kurosaka, D. (2014) · Current Eye Research · doi:10.3109/02713683.2014.915575 · Cited by 39
Machida, S., Kaneko, M., & Kurosaka, D. (2014) · Current Eye Research · doi:10.3109/02713683.2014.922196 · Cited by 38
Multifocal Electroretinogram with a Multiflash Stimulation Technique in Open-Angle Glaucoma
Palmowski-Wolfe, A. M., Allgayer, R., Heinemann-Vernaleken, B., & Ruprecht, K. W. (2002) · Ophthalmic Research · doi:10.1159/000048333 · Cited by 37
Kremers, J., Jertila, M., Link, B., Pangeni, G., & Horn, F. K. (2012) · Documenta Ophthalmologica · doi:10.1007/s10633-011-9304-z · Cited by 31
Multifocal Pattern Electroretinogram: Cellular Origins and Clinical Implications
Harrison, W. W., Viswanáthan, S., & Malinovsky, V. E. (2006) · Optometry and Vision Science · doi:10.1097/01.opx.0000218319.61580.a5 · Cited by 29
Luo, X., Patel, N. B., Rajagopalan, L., Harwerth, R. S., & Frishman, L. J. (2014) · Investigative Ophthalmology & Visual Science · doi:10.1167/iovs.14-13937 · Cited by 29
Pattern electroretinogram to detect glaucoma: comparing the PERGLA and the PERG Ratio protocols
Bach, M., & Ramharter, A. (2013) · Documenta Ophthalmologica · doi:10.1007/s10633-013-9412-z · Cited by 28 · cited 1×
“[29] in terms of the PERG stimulus, electrodes, and response analysis, yet readers may find it reassuring that the results were nonetheless similar and that the same differences did not substantially impact diagnostic accuracy when compared directly in another recent study by Bach and colleagues [30].”
ResultThe ‘two global flash’ mfERG in high and normal tension primary open-angle glaucoma
Palmowski-Wolfe, A. M., Todorova, M. G., Orgül, S., Flammer, J., & Brigell, M. (2006) · Documenta Ophthalmologica · doi:10.1007/s10633-006-9033-x · Cited by 24
Luminance-Modulated Adaptation of Global Flash mfERG: Fellow Eye Losses in Asymmetric Glaucoma
Chu, P. H. W., Chan, H. H., & Brown, B. H. (2007) · Investigative Ophthalmology & Visual Science · doi:10.1167/iovs.06-0962 · Cited by 22
Binns, A. M., Mortlock, K. E., & North, R. V. (2011) · Documenta Ophthalmologica · doi:10.1007/s10633-010-9257-7 · Cited by 19
Bui, B. V., Fortune, B. A., Cull, G. A., Wang, L., & Cioffi, G. A. (2003) · Experimental Eye Research · doi:10.1016/s0014-4835(03)00195-7 · Cited by 16
Self-citationLedolter, A. A., Monhart, M., Schoetzau, A., Todorova, M. G., & Palmowski-Wolfe, A. M. (2015) · Documenta Ophthalmologica · doi:10.1007/s10633-015-9482-1 · Cited by 13
Characteristics of late negative ERG responses elicited by sawtooth flicker
Gowrisankaran, S., Genead, M. A., Anastasakis, A., & Alexander, K. R. (2012) · Documenta Ophthalmologica · doi:10.1007/s10633-012-9352-z · Cited by 12 · cited 1×
“These opposing contributions can be teased apart by extending the duration of the stimulus or by using ‘saw-tooth’ periodic stimulation [4,5].”
BackgroundChu, P. H. W., Ng, Y. F., To, C. H., So, K., Brown, B. H., & Chan, H. H. (2011) · Graefe s Archive for Clinical and Experimental Ophthalmology · doi:10.1007/s00417-011-1790-x · Cited by 6
Research works printed but not linked: 2
- Heckenlively JR Arden GB Principles and practice of clinical electrophysiology of vision 2006 Cambridge, MA The MIT Press
- Graham SL Fortune B Shaarawy TM Sherwood MB Hitchings RA Crowston JG Electrophysiology in Glaucoma Assessment Glaucoma 2015 2nd. London Elsevier 149 168
Cited by
Agostinone, J., Alarcon-Martinez, L., Gamlin, C., Yu, W.-Q., Wong, R. O. L., & Di Polo, A. (2018) · Brain · doi:10.1093/brain/awy142 · Cited by 124
“The pSTR and PhNR derive predominantly from RGC activity in the rodent retina, and are reduced after optic nerve injury and in glaucoma patients (Bui and Fortune, 2004; Alarcón-Martı́nez et al., 2010; Chrysostomou and Crowston, 2013; Smith et al., 2014; Wilsey and Fortune, 2016).”
Li, Q., Cheng, Y., Zhang, S., Sun, X., & Wu, J. (2021) · Journal of Neuroinflammation · doi:10.1186/s12974-021-02315-8 · Cited by 126
The coma in glaucoma: Retinal ganglion cell dysfunction and recovery
Fry, L. E., Fahy, E. T., Chrysostomou, V., Hui, F., Tang, J., van Wijngaarden, P., Petrou, S., & Crowston, J. G. (2018) · Progress in Retinal and Eye Research · doi:10.1016/j.preteyeres.2018.04.001 · Cited by 107
“Components of the full field ERG, the positive scotopic threshold response (pSTR) and the photopic negative response (PhNR), can be used to measure inner retinal function (Wilsey and Fortune, 2016).”
BackgroundMethodNeuro-protective Mechanisms of Lycium barbarum
Xing, X., Liu, F., Xiao, J., & So, K. (2016) · NeuroMolecular Medicine · doi:10.1007/s12017-016-8393-y · Cited by 79
“For example, the alkaline extract of wolfberry (contains LBP) protects neuron through elevating the pro-survival Akt pathway, while the water extraction of wolfberry (main constituents of LBP) mainly plays its neuronal beneficial effects via inhibiting the apoptotic pathway and related JNK/PKR…”
BackgroundZhang, Z., Peng, S., Xu, T., Liu, J., Zhao, L., Xu, H. Z., Zhang, W., Zhu, Y., & Yang, Z. (2023) · Advanced Science · doi:10.1002/advs.202302909 · Cited by 90
Metadata
- Authors
- Wilsey, L. J., & Fortune, B.
- Affiliations
- Legacy Health (US)
- Corresponding author
- Fortune, Brad
- Venue
- Current Opinion in Ophthalmology
- Published
- 2016-03
- Volume
- 27
- Issue
- 2
- Pages
- 118-124
- ISSN
- 1040-8738 (ISSN-L)
- PMC
- PMC4698880
- OpenAlex
- W2409899358
- Cited by
- 113
- References
- 72
- Citations by year
- 2026: 3 · 2025: 11 · 2024: 8 · 2023: 11 · 2022: 19 · 2021: 19 · 2020: 10 · 2019: 13 · 2018: 7 · 2017: 8 · 2016: 4
- FWCI
- 1.17
- Type
- journal article
- Language
- en
- Open access
- green
- www.ncbi.nlm.nih.gov
- Locations
- Current Opinion in Ophthalmology (publishedVersion)
- PubMed (publishedVersion)
- Europe PMC (PubMed Central) (acceptedVersion)
- PubMed Central (acceptedVersion)
- Funders
- National Eye Institute (R01EY019327)
- Topics
- Health Sciences › Medicine › Ophthalmology › Glaucoma and retinal disorders
- Health Sciences › Medicine › Ophthalmology › Retinal Development and Disorders
- Health Sciences › Medicine › Ophthalmology › Drug-Induced Ocular Toxicity
- Keywords
- electroretinogram, glaucoma diagnosis, photopic negative response, retinal ganglion cell function, retinal nerve fiber layer thinning, risk stratification, early glaucomatous damage
- MeSH terms
- Animals, Electroretinography, Glaucoma, Humans, Retina, Retinal Ganglion Cells, Visual Fields
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.