Electroretinography in glaucoma diagnosis
Open accessThe DOI matches its Crossref record; 72 of the 72 references it cites were found in a registry or an index.
Abstract
PURPOSE OF REVIEW: Electrophysiological measures of vision function have for decades generated interest among glaucoma researchers and clinicians alike because of their potential to help elucidate pathophysiological processes and sequence of glaucomatous damage, as well as to offer a potential complementary metric of function that might be more sensitive than standard automated perimetry. The purpose of this article is to review the recent literature to provide an update on the role of the electroretinogram (ERG) in glaucoma diagnosis. RECENT FINDINGS: The pattern reversal ERG (PERG) and the photopic negative response (PhNR) of the cone-driven full-field, focal or multifocal ERG provide objective measures of retinal ganglion cell function and are all sensitive to glaucomatous damage. Recent studies demonstrate that a reduced PERG amplitude is predictive of subsequent visual field conversion (from normal to glaucomatous) and an increased rate of progressive retinal nerve fiber layer thinning in suspect eyes, indicating a potential role for PERG in risk stratification. Converging evidence indicates that some portion of PERG and PhNR abnormality represents a reversible aspect of dysfunction in glaucoma. SUMMARY: PERG and PhNR responses obtained from the central macula are capable of detecting early-stage, reversible glaucomatous dysfunction.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
The field topography of ERG components in man—I. The photopic luminance response
Sutter, E. E., & Tran, D. (1992) · Vision Research · doi:10.1016/0042-6989(92)90235-b · Cited by 946
Oscillatory potentials in the retina: what do they reveal
Wachtmeister, L. (1998) · Progress in Retinal and Eye Research · doi:10.1016/s1350-9462(98)00006-8 · Cited by 529 · cited 1×
“The OPs are thought to arise within the inner plexiform layer as a consequence of inhibitory feedback loops involving primarily amacrine cells [2].”
BackgroundAssessing retinal function with the multifocal technique
Hood, D. C. (2000) · Progress in Retinal and Eye Research · doi:10.1016/s1350-9462(00)00013-6 · Cited by 481 · cited 2×
“There are additional types of ERG recordings based on alternative stimulus and recording paradigms rather than full-field flashes such as the well known pattern reversal ERG (PERG) [22] and multifocal ERG (mfERG) [23], which can also be obtained in a routine clinical setting and offer meaningful objective measurements…”
BackgroundThe photopic negative response of the macaque electroretinogram: reduction by experimental glaucoma.
Viswanáthan, S., Frishman, L. J., Robson, J. G., Harwerth, R. S., & Smith, E. L. (1999) · PubMed · Cited by 417
Sieving, P. A., Murayama, K., & Naarendorp, F. (1994) · Visual Neuroscience · doi:10.1017/s0952523800002431 · Cited by 388
The topography of visual evoked response properties across the visual field
Baseler, H. A., Sutter, E. E., Klein, S. A., & Carney, T. (1994) · Electroencephalography and Clinical Neurophysiology · doi:10.1016/0013-4694(94)90114-7 · Cited by 320
The Scotopic Threshold Response of the Dark‐Adapted Electroretinogram of the Mouse
Saszik, S. M., Robson, J. G., & Frishman, L. J. (2002) · The Journal of Physiology · doi:10.1113/jphysiol.2002.019703 · Cited by 295
The photopic negative response of the flash electroretinogram in primary open angle glaucoma.
Viswanáthan, S., Frishman, L. J., Robson, J. G., & Walters, J. W. (2001) · PubMed · Cited by 273
Viswanáthan, S., Frishman, L. J., & Robson, J. G. (2000) · PubMed · Cited by 255
Multifocal VEP and ganglion cell damage: applications and limitations for the study of glaucoma
Hood, D. (2003) · Progress in Retinal and Eye Research · doi:10.1016/s1350-9462(02)00061-7 · Cited by 245 · cited 1×
“Thorough reviews of the clinical applications of multifocal ERG and visual evoked response (VER) were published by Hood in 2000 [23] and 2003 [47], respectively.”
Background
Research works printed but not linked: 2
- Heckenlively JR Arden GB Principles and practice of clinical electrophysiology of vision 2006 Cambridge, MA The MIT Press
- Graham SL Fortune B Shaarawy TM Sherwood MB Hitchings RA Crowston JG Electrophysiology in Glaucoma Assessment Glaucoma 2015 2nd. London Elsevier 149 168
Cited by
Agostinone, J., Alarcon-Martinez, L., Gamlin, C., Yu, W.-Q., Wong, R. O. L., & Di Polo, A. (2018) · Brain · doi:10.1093/brain/awy142 · Cited by 124
“The pSTR and PhNR derive predominantly from RGC activity in the rodent retina, and are reduced after optic nerve injury and in glaucoma patients (Bui and Fortune, 2004; Alarcón-Martı́nez et al., 2010; Chrysostomou and Crowston, 2013; Smith et al., 2014; Wilsey and Fortune, 2016).”
Li, Q., Cheng, Y., Zhang, S., Sun, X., & Wu, J. (2021) · Journal of Neuroinflammation · doi:10.1186/s12974-021-02315-8 · Cited by 128
The coma in glaucoma: Retinal ganglion cell dysfunction and recovery
Fry, L. E., Fahy, E. T., Chrysostomou, V., Hui, F., Tang, J., van Wijngaarden, P., Petrou, S., & Crowston, J. G. (2018) · Progress in Retinal and Eye Research · doi:10.1016/j.preteyeres.2018.04.001 · Cited by 107
“Components of the full field ERG, the positive scotopic threshold response (pSTR) and the photopic negative response (PhNR), can be used to measure inner retinal function (Wilsey and Fortune, 2016).”
BackgroundMethodNeuro-protective Mechanisms of Lycium barbarum
Xing, X., Liu, F., Xiao, J., & So, K. (2016) · NeuroMolecular Medicine · doi:10.1007/s12017-016-8393-y · Cited by 79
“For example, the alkaline extract of wolfberry (contains LBP) protects neuron through elevating the pro-survival Akt pathway, while the water extraction of wolfberry (main constituents of LBP) mainly plays its neuronal beneficial effects via inhibiting the apoptotic pathway and related JNK/PKR…”
BackgroundZhang, Z., Peng, S., Xu, T., Liu, J., Zhao, L., Xu, H. Z., Zhang, W., Zhu, Y., & Yang, Z. (2023) · Advanced Science · doi:10.1002/advs.202302909 · Cited by 90
Belforte, N., Agostinone, J., Alarcon-Martinez, L., Villafranca-Baughman, D., Dotigny, F., Cueva Vargas, J. L., & Di Polo, A. (2021) · Molecular Neurodegeneration · doi:10.1186/s13024-021-00466-z · Cited by 67
“To assess the impact of siAMPK on RGC function, we measured the positive scotopic threshold response (pSTR), a component of the electroretinogram (ERG) that derives predominantly from RGC activity [48, 49].”
MethodManagement of advanced glaucoma: Characterization and monitoring
Moraes, C. G. D., Liebmann, J. M., Medeiros, F. A., & Weinreb, R. N. (2016) · Survey of Ophthalmology · doi:10.1016/j.survophthal.2016.03.006 · Cited by 73
Measurable Aspects of the Retinal Neurovascular Unit in Diabetes, Glaucoma, and Controls
Spaide, R. F. (2019) · American Journal of Ophthalmology · doi:10.1016/j.ajo.2019.04.035 · Cited by 68
Gubin, D. G., Malishevskaya, Т. N., Astakhov, Y. S., Astakhov, S. Y., Cornélissen, G., Va, K., & Weinert, D. (2019) · Chronobiology International · doi:10.1080/07420528.2019.1566741 · Cited by 59
“Pattern electroretinogram, PERG, is a predictive method to assess glaucoma development (Ventura et al. 2005) and a useful tool to estimate the risk of glaucoma progression (Ventura et al. 2005, Wilsey and Fortune 2016).”
MethodZhao, L., Ling, L., Lu, J., Jiang, F., Sun, J., Zhang, Z., Huang, Y., Liu, X., Zhu, Y., Fu, X., et al. (2022) · Bioengineering & Translational Medicine · doi:10.1002/btm2.10460 · Cited by 53
“OPs are considered to arise within the IPL due to an inhibitory feedback loop mainly involving amacrine cells.(58) In the present study, OPs were also monitored.”
BackgroundQuintero, H., Shiga, Y., Belforte, N., Alarcón-Martínez, L., Hajji, S. E., Villafranca‐Baughman, D., Dotigny, F., & Polo, A. D. (2022) · Cell Reports · doi:10.1016/j.celrep.2022.111324 · Cited by 50
Gao, F., Zhang, S.-H., Xu, P., Yang, B., Zhang, R., Cheng, Y., Zhou, X., Huang, W., Wang, M., Chen, J., et al. (2017) · Frontiers in Molecular Neuroscience · doi:10.3389/fnmol.2017.00285 · Cited by 47
“…PhNR is a slow negative component of the photopic full-field ERG that follows the b-wave, and it can capture RGC function throughout the entire visual field, providing a direct, objective assessment of the functional changes of RGCs (Preiser et al., 2013; Porciatti, 2015; Wilsey and Fortune, 2016).”
BackgroundThe Role of Retinal Ganglion Cell Structure and Function in Glaucoma
Feng, K. M., Tsung, T., Chen, Y., & Lu, D. (2023) · Cells · doi:10.3390/cells12242797 · Cited by 52
“Multifocal ERG, introduced in 1992, enables numerous localized retinal responses to be identified from a single recording [101].”
BackgroundValidity, Usefulness and Cost of RET eval System for Diabetic Retinopathy Screening
Alotaibi, H., Alotaibi, M. D., Khandekar, R. B., Souru, C., Al-Abdullah, A. A., Al-Dhibi, H. A., Stone, D. U., & Kozak, I. (2017) · Translational Vision Science & Technology · doi:10.1167/tvst.6.3.3 · Cited by 43
“In patients with false-positive results by RETeval, a secondary chart review was performed to determine the presence of other ocular diseases that might explain an abnormal ERG, such as glaucoma, optic atrophy, or chorioretinal abnormalities.(19,20)”
BackgroundSenger, C., Moreto, R., Watanabe, S. E. S., Matos, A. G., & Paula, J. S. (2019) · Journal of Glaucoma · doi:10.1097/ijg.0000000000001422 · Cited by 38
Monte, M. D., Cammalleri, M., Amato, R., Pezzino, S., Corsaro, R., Bagnoli, P., & Rusciano, D. (2020) · International Journal of Molecular Sciences · doi:10.3390/ijms21239267 · Cited by 34
“To this aim, the photopic negative response (PhNR), a negative-going wave following the b-wave of the cone electroretinogram (ERG), and the pattern ERG (PERG) in response to contrast-reversing gratings, both indicative of RGC activity [31], were recorded to evaluate whether melatoninergic compounds may counteract reti…”
BackgroundInfluentialWill Perimetry Be Performed to Monitor Glaucoma in 2025?
Camp, A. S., & Weinreb, R. N. (2017) · Ophthalmology · doi:10.1016/j.ophtha.2017.04.009 · Cited by 34
“Pattern electroretinography measures the electrical activity generated by a pattern stimulus delivered to the macula.(23) Pattern electroretinography effectively detects preperimetric glaucoma patients, but requires a relatively skilled examiner and can be influenced by media opacity.”
BackgroundWilsey, L. J., Gowrisankaran, S., Cull, G. A., Hardin, C., Burgoyne, C. F., & Fortune, B. A. (2017) · Documenta Ophthalmologica · doi:10.1007/s10633-017-9578-x · Cited by 34
“Each technique has its advantages and drawbacks [15, 24], the balance of which may depend on the setting (e.”
BackgroundSelf-citationLocri, F., Cammalleri, M., Monte, M. D., Rusciano, D., & Bagnoli, P. (2019) · Nutrients · doi:10.3390/nu11122931 · Cited by 35
“In addition, PhNR can be easily recorded using conventional ERG thus allowing to determine the aand b-wave amplitudes that reflect the function of the retinal layers above RGCs that, instead, do not participate in ERG generation [15].”
MethodRetractedComparative analysis of retinal ganglion cell damage in three glaucomatous rat models
Huang, W., Hu, F., Wang, M., Gao, F., Xu, P., Xing, C., Sun, X., Zhang, S., & Wu, J. (2018) · Experimental Eye Research · doi:10.1016/j.exer.2018.03.019 · Cited by 34
“(Wilsey and Fortune, 2016) reported that the PhNR originates from the inner retina layer and can provide a direct, objective assessment of RGCs(Porciatti, 2015).”
XEN Gel Stent in the management of primary open-angle glaucoma
Post, M. H., Lubiński, W., Śliwiak, D., Podborączyńska‐Jodko, K., & Mularczyk, M. (2020) · Documenta Ophthalmologica · doi:10.1007/s10633-020-09753-4 · Cited by 32
Gajendran, M. K., Rohowetz, L. J., Koulen, P., & Mehdizadeh, A. (2022) · Frontiers in Neuroscience · doi:10.3389/fnins.2022.869137 · Cited by 32
“In particular, studies conducted by Wilsey and Fortune (2016), Hermas (2019), Beykin et al. (2021) investigating the variability of PhNR in glaucomatous and healthy subjects in PERG and fERG have found that PhNR to be an important biomarkers for detection of glaucoma.”
BackgroundAsiatic Acid Prevents Retinal Ganglion Cell Apoptosis in a Rat Model of Glaucoma
Huang, W., Gao, F., Hu, F., Huang, J., Wang, M., Xu, P., Zhang, R., Chen, J., Sun, X., Zhang, S., et al. (2018) · Frontiers in Neuroscience · doi:10.3389/fnins.2018.00489 · Cited by 32
“The PhNR amplitudes are well correlated with the thickness of the ganglion cell complex within the central macula and provide a direct, objective assessment of the changes in RGC function (Wilsey and Fortune, 2016).”
BackgroundMyopia-26, the female-limited form of early-onset high myopia, occurring in a European family
Széll, N., Fehér, T., Maróti, Z., Kalmár, T., Latinovics, D., Nagy, I., Orosz, Z. Z., Janáky, M., Facskó, A., & Sohajda, Z. (2021) · Orphanet Journal of Rare Diseases · doi:10.1186/s13023-021-01673-z · Cited by 30
Sanjay, S., Park, M., & Lee, H. (2022) · International Journal of Molecular Sciences · doi:10.3390/ijms23137300 · Cited by 31
Comparison of photopic negative response measurements in the time and time–frequency domains
Kundra, H., Park, J. C., & McAnany, J. J. (2016) · Documenta Ophthalmologica · doi:10.1007/s10633-016-9558-6 · Cited by 27
Gramlich, O. W., Godwin, C. R., Wadkins, D., Elwood, B. W., & Kuehn, M. H. (2021) · International Journal of Molecular Sciences · doi:10.3390/ijms22147581 · Cited by 26
Neroev, V. V., Malishevskaya, Т. N., Weinert, D., Astakhov, S., Kolomeichuk, S. N., Cornélissen, G., Kabitskaya, Y., Бойко, Е. А., Nemtsova, I. V., & Gubin, D. G. (2020) · International Journal of Molecular Sciences · doi:10.3390/ijms22010359 · Cited by 24
“Functional ability of RGC was also assessed by using amplitude of pattern electroretinogram (PERG), a valid method to predict the development and progression of glaucoma [50,51].”
MethodRelationship between pattern electroretinogram and optic disc morphology in glaucoma
Jeon, S. J., Park, H.-Y. L., Jung, K. I., & Park, C. K. (2019) · PLoS ONE · doi:10.1371/journal.pone.0220992 · Cited by 24
Gao, F., Wu, J., Li, T., Du, S., & Wu, Q. E. (2017) · Frontiers in Molecular Neuroscience · doi:10.3389/fnmol.2017.00076 · Cited by 24
“It provides a direct, objective assessment of the functional changes in the RGCs (Wilsey and Fortune, 2016).”
BackgroundFeature Extraction Methods for Electroretinogram Signal Analysis: A Review
Behbahani, S., Ahmadieh, H., & Rajan, S. (2021) · IEEE Access · doi:10.1109/access.2021.3103848 · Cited by 23
“that directly follows the a-wave and usually has a significant positive amplitude [21], [22].”
BackgroundLocri, F., Cammalleri, M., Pini, A., Monte, M. D., Rusciano, D., & Bagnoli, P. (2018) · Nutrients · doi:10.3390/nu10101447 · Cited by 24
Influences of Glaucoma on the Structure and Function of Synapses in the Visual System
Hook, M. J. V. (2022) · Antioxidants and Redox Signaling · doi:10.1089/ars.2021.0253 · Cited by 21
“Comparisons of PERG with in vivo measurements of inner retinal thickness with OCT imaging showed that PERG began declining * 8 years before detectable thinning of the inner retina, suggesting that functional deficits precede structural deficits (7, 12, 109, 126, 177, 192, 193).”
An optimized procedure to record visual evoked potential in mice
Liu, S., Xiang, K., Lei, Q., Qiu, S., Xiang, M., & Jin, K. (2022) · Experimental Eye Research · doi:10.1016/j.exer.2022.109011 · Cited by 21
Non-invasive electrophysiology in glaucoma, structure and function—a review
Al-Nosairy, K. O., Hoffmann, M. B., & Bach, M. (2021) · Eye · doi:10.1038/s41433-021-01603-0 · Cited by 20
“ERG measures of visual function do not offer superiority for monitoring later stages of glaucoma progression, where PERG decreases early and its amplitude might not decline much further with disease progression [22, 40, 70].”
BackgroundMethodPark, Y. H., Snook, J. D., Ostrin, E. J., Kim, S., Chen, R., & Frankfort, B. J. (2019) · Scientific Reports · doi:10.1038/s41598-019-39141-1 · Cited by 23
Probing ON and OFF Retinal Pathways in Glaucoma Using Electroretinography
Kong, A. W., Santina, L. D., & Ou, Y. (2020) · Translational Vision Science & Technology · doi:10.1167/tvst.9.11.14 · Cited by 21
de Santiago, L., del Castillo, M. O., García‐Martín, E., Rodrigo, M. J., Sánchez‐Morla, E. M., Cavaliere-Ballesta, C., Ciordía, B. C., Miguel, J. M., López-Dorado, A., & Boquete, L. (2019) · Sensors · doi:10.3390/s20010007 · Cited by 19
“Traditional analysis of mfERG recordings is based on obtaining the amplitudes and latencies of these waves, and has been shown to be effective in diagnosing glaucoma [13] or age-related macular degeneration [14], among other diseases.”
BackgroundReview: Neuroprotective Nanocarriers in Glaucoma
Pei, K., Georgi, M., Hill, D., Lam, C. F. J., Wei, W., & Cordeiro, M. F. (2024) · Pharmaceuticals · doi:10.3390/ph17091190 · Cited by 19
“For instance, pattern ERG (PERG) and PhNR, which is the negative wave after b-wave, could provide a better assessment of the RGC’s function [133].”
BackgroundMethodLi, Z., Xie, F., Yang, N., Yang, J., Luo, J., Hua, D., He, T., & Xing, Y. (2021) · Experimental Eye Research · doi:10.1016/j.exer.2021.108587 · Cited by 18
Al-Nosairy, K. O., Prabhakaran, G. T., Pappelis, K., Thieme, H., & Hoffmann, M. B. (2020) · Translational Vision Science & Technology · doi:10.1167/tvst.9.12.7 · Cited by 16
“Two ERG-based approaches provide sensitive information about the pathophysiology of glaucoma damage, 24 i.e. pattern ERG (PERG) and photopic negative responses (PhNR).”
Test–retest repeatability of the pattern electroretinogram and flicker electroretinogram
Resende, A., Sanvicente, C., Eshraghi, H., García, A., Pickel, K., Zhang, Q., Waisbourd, M., & Katz, L. J. (2019) · Documenta Ophthalmologica · doi:10.1007/s10633-019-09707-5 · Cited by 16
Long-term PERG monitoring of untreated and treated glaucoma suspects
Gordon, P., Kostic, M., Monsalve, P., Triolo, G., Golubev, L., Luna, G., Ventura, L. M., Feuer, W. J., & Porciatti, V. (2020) · Documenta Ophthalmologica · doi:10.1007/s10633-020-09760-5 · Cited by 14
Is multifocal electroretinography an early predictor of glaucoma?
Gölemez, H., Yıldırım, N., & Özer, A. (2016) · Documenta Ophthalmologica · doi:10.1007/s10633-016-9524-3 · Cited by 14
“[44] reviewed glaucoma and electroretinography.”
Abed, E., Placidi, G., Campagna, F., Federici, M., Minnella, A. M., Guerri, G., Bertelli, M., Piccardi, M., Galli‐Resta, L., & Falsini, B. (2017) · Clinical and Experimental Ophthalmology · doi:10.1111/ceo.13115 · Cited by 14
Retinal dysfunction characterizes subtypes of dominant optic atrophy
Cascavilla, M. L., Parisi, V., Triolo, G., Ziccardi, L., Borrelli, E., Renzo, A. D., Balducci, N., Lamperti, C., Marzoli, S. B., Darvizeh, F., et al. (2017) · Acta Ophthalmologica · doi:10.1111/aos.13557 · Cited by 13
Macular Blood Flow and Pattern Electroretinogram in Normal Tension Glaucoma
Jeon, S. J., Jung, K. I., Park, C. K., & Park, H.-Y. L. (2022) · Journal of Clinical Medicine · doi:10.3390/jcm11071790 · Cited by 11
Novel ocular findings in oculodentodigital dysplasia (ODDD): a case report and literature review
Wang, Z., Sun, L., Wang, P., Chen, C., Zhang, A., Wang, W., & Ding, X. (2019) · Ophthalmic Genetics · doi:10.1080/13816810.2019.1571616 · Cited by 9
Lee, J., Kim, S. A., Lee, J., Park, C. K., & Jung, K. I. (2022) · Scientific Reports · doi:10.1038/s41598-022-17868-8 · Cited by 8
The p-ERG spatial acuity in the biomedical pig under physiological conditions
Ventrella, D., Maya‐Vetencourt, J. F., Elmi, A., Barone, F., Aniballi, C., Muscatello, L. V., Mete, M., Pertile, G., Benfenati, F., & Bacci, M. L. (2022) · Scientific Reports · doi:10.1038/s41598-022-19925-8 · Cited by 9
Barbano, L., Ziccardi, L., Antonelli, G., Nicoletti, C. G., Landi, D., Mataluni, G., Falsini, B., Marfia, G. A., Centonze, D., & Parisi, V. (2022) · Diagnostics · doi:10.3390/diagnostics12051156 · Cited by 8
“On the functional evaluation of the IRL, beside PERG recordings [9,10], the measure of the full-field photopic negative response (ff-PhNR) of light-adapted ff-ERG has been suggested [27–34].”
BackgroundInfluentialBekollari, M., Dettoraki, M., Stavrou, V., Skouroliakou, A., & Liaparinos, P. F. (2023) · Sensors · doi:10.3390/s23094504 · Cited by 8
Zeng, S., Du, L., Lu, G., & Xing, Y. (2023) · Molecular Neurobiology · doi:10.1007/s12035-023-03466-w · Cited by 8
Brandão, L. M., Ledolter, A. A., Monhart, M., Schötzau, A., & Palmowski-Wolfe, A. M. (2017) · Graefe s Archive for Clinical and Experimental Ophthalmology · doi:10.1007/s00417-017-3722-x · Cited by 7
Dunn, M., Cull, G. A., Reynaud, J. F., Jennings, D., Holthausen, T., Polo, A. D., & Fortune, B. A. (2023) · Translational Vision Science & Technology · doi:10.1167/tvst.12.8.16 · Cited by 6
“6,9,11 Another benefit of full-field photopic ERG recordings is that, along with the PhNR measurement of RGC function, they also provide direct simultaneous assessment of distal retinal function (cone and cone bipolar cell responses via a-wave and b-wave measurements).”
Self-citationRemodeling the light-adapted electroretinogram using a bayesian statistical approach
Brabec, M., Marmolejo‐Ramos, F., Loh, L., Lee, I., Kulyabin, M., Zhdanov, A. E., Posada-Quintero, H. F., Thompson, D., & Constable, P. A. (2025) · BMC Research Notes · doi:10.1186/s13104-025-07115-4 · Cited by 6
Mushtaq, Y., Panchasara, B., Nassehzadeh-Tabriz, N., Lim, H. K., Mushtaq, M., Kean, J., Farrell, S., Bourne, R., Shahid, H., Khatib, T. Z., et al. (2021) · Eye · doi:10.1038/s41433-021-01492-3 · Cited by 6
Use of multifocal electroretinograms to determine stage of glaucoma
Moroto, N., Nakakura, S., Tabuchi, H., Mochizuki, K., Manabe, Y., & Sakaguchi, H. (2023) · PLoS ONE · doi:10.1371/journal.pone.0278234 · Cited by 6
Neroev, V. V., Зуева, М. В., Zhuravleva, A. N., & Цапенко, И. В. (2020) · Ophthalmology in Russia · doi:10.18008/1816-5095-2020-3s-533-541 · Cited by 6
Pupillometric recordings to detect glaucoma
Bhowmik, S., Arjunan, S. P., Sarossy, M., Radcliffe, P., & Kumar, D. (2021) · Physiological Measurement · doi:10.1088/1361-6579/abf05c · Cited by 6
“Thus, there is an increase in the time delay to respond to the light conditions or stimuli, and this has been investigated using an electroretinogram (Wilsey and Fortune 2016).”
MethodElsamkary, M., El-Shazly, A. A. E.-F., Badran, T. A. F., Fouad, Y. A., & Abdelgawad, R. H. A. (2022) · International Ophthalmology · doi:10.1007/s10792-022-02605-x · Cited by 5
“Their results have also been shown to correlate with the clinical presentation and staging of the patients [11, 12].”
ResultLee, M. Y., Park, H.-Y. L., Kim, S. A., Jung, Y., & Park, C. K. (2022) · Journal of Glaucoma · doi:10.1097/ijg.0000000000002088 · Cited by 5
Hong, E., Glynn, C. J., Wang, Q., & Rao, S. (2022) · Biosensors · doi:10.3390/bios13010042 · Cited by 5
“As a non-invasive electrical recording technique, electroretinography (ERG) has been used in ophthalmologic diagnosis to identify glaucoma [9,10].”
MethodTanaka, H., Ishida, K., Ozawa, K., Ishihara, T., Sawada, A., Mochizuki, K., & Yamamoto, T. (2021) · BMC Ophthalmology · doi:10.1186/s12886-021-02061-8 · Cited by 5
Hermas, A., Tsilfidis, C., Karanjia, R., Miller, G., Kantungane, A., El-Salibi, A., Kherani, I., Bali, S. J., & Coupland, S. G. (2024) · Documenta Ophthalmologica · doi:10.1007/s10633-023-09960-9 · Cited by 4
“Electroretinography (ERG) provides an objec-tive measure of retinal function by recording the retinal electrical response to a transient flash stimulus [13, 14].”
Kudrna, J. J., Ferguson, T. J., Swan, R. J., Ferguson, S. J., Baartman, B. J., Bleeker, A. R., Sudhagoni, R. G., Berdahl, J. P., & Greenwood, M. D. (2020) · Ophthalmology and Therapy · doi:10.1007/s40123-020-00302-5 · Cited by 4
Steady-State Pattern Electroretinography in Eyes with Glaucoma and High Myopia
Lim, X. H., Nongpiur, M. E., Najjar, R. P., Hoang, Q. V., Miléa, D., Wong, K. H., Husain, R., Htoon, H. M., Aung, T., Perera, S., et al. (2021) · Clinical ophthalmology · doi:10.2147/opth.s336903 · Cited by 4
“PERG typically assesses the central visual field and utilises an alternating, patterned visual stimulus with spatial and temporal variations that culminate in a constant, mean luminance.(11) At reversal frequencies of 5Hz (10 reversals/ second) or more, individual PERG waveforms merge and the retinal response to this…”
BackgroundNordahl, K. M. L., Fedulov, V., Holm, A., & Haanes, K. A. (2023) · Cells · doi:10.3390/cells12151987 · Cited by 4
Munuera, I., Aragón-Navas, A., Villacampa, P., González-Cela-Casamayor, M. A., Subías, M., Pablo, L. E., Garcia-Feijoo, J., Herrero‐Vanrell, R., García‐Martín, E., Bravo‐Osuna, I., et al. (2023) · International Journal of Molecular Sciences · doi:10.3390/ijms25010009 · Cited by 4
Biologically Driven In Vivo Occlusion Design Provides a Reliable Experimental Glaucoma Mouse ModelPreprint
Hong, E., Wang, Q., Yang, R., Tian, F., Donahue, R., Li, X., Glynn, C., Tsekov, S., Chen, L., Xiong, M., et al. (2024) · bioRxiv (Cold Spring Harbor Laboratory) · doi:10.1101/2024.01.18.576306 · Cited by 6
Tirsi, A., Tsai, J., Abizadeh, A., Kacaj, D., Procyk, O., Gliagias, V., Leung, N., Yang, H., Park, S. C., & Tello, C. A. (2025) · Clinical ophthalmology · doi:10.2147/opth.s483055 · Cited by 3
The Use of the RETeval Portable Electroretinography Device for Low-Cost Screening: A Mini-Review
Saad, A., Turgut, F., Sommer, C., Becker, M. D., DeBuc, D. C., Barboni, M. T. S., & Somfai, G. M. (2024) · Klinische Monatsblätter für Augenheilkunde · doi:10.1055/a-2237-3814 · Cited by 3
“ERG research in glaucoma has advanced the diagnostic assessment of retinal function [6,15].”
BackgroundModern view on ocular hypertension
Erichev, V. P., & Панюшкина, Л. А. (2019) · Russian Annals of Ophthalmology · doi:10.17116/oftalma2019135052305 · Cited by 3
Visual function tests for glaucoma practice - What is relevant?
Rao, A., Padhy, D., Pal, A., & Roy, A. K. (2022) · Indian Journal of Ophthalmology · doi:10.4103/ijo.ijo_1390_21 · Cited by 3
“Bayer et al.[68] examined SWAP, frequency doubling technique perimetry (FDT), and pattern ERG in patients with primary open‑angle (POAG) and found that SWAP MD and PERG P1N2 amplitudes diagnose early glaucomatous functional damage in POAG patients even with a normal SAP.”
BackgroundInfluentialZhang, M., Yang, J., Ji, K., He, X., He, T., & Xing, Y. (2022) · Experimental Eye Research · doi:10.1016/j.exer.2022.109082 · Cited by 3
Park, S. J., Paik, S.-S., Lee, J., Oh, S.-J., & Kim, I. (2018) · Experimental Neurobiology · doi:10.5607/en.2018.27.3.210 · Cited by 3
Striebel, J. F., Carroll, J. A., Race, B., Leung, J. M., Schwartz, C. L., Reese, E. D., Rickman, C. B., Chesebro, B. W., & Klingeborn, M. (2024) · iScience · doi:10.1016/j.isci.2024.110954 · Cited by 2
McAnany, J. J., Park, J. C., Barrionuevo, P. A., Shah, D., Vajaranant, T. S., Aref, A. A., Edward, D. P., & Hyde, R. A. (2025) · Documenta Ophthalmologica · doi:10.1007/s10633-025-10040-3 · Cited by 2
“Although POAG is not typically associated with full-field ERG abnormalities under standard ISCEV conditions, there have been reports of full-field ERG reductions in end-stage glaucoma [20, 21], but ERG full-field abnormalities in glaucoma remain controversial [8, 22].”
Long, D., Li, Y., Yi, S., & Lu, X. (2025) · Scientific Reports · doi:10.1038/s41598-025-26957-3 · Cited by 2
“The PhNR directly originates from RGCs or is mediated by amacrine cells and glial cells 23 .”
Improving the reliability of the pattern electroretinogram with adaptive filtering
Angus, Z. G., Sarossy, A., Parihar, P., & Sarossy, M. (2025) · Scientific Reports · doi:10.1038/s41598-025-30929-y · Cited by 2
“The ERG has utility in the diagnosis and monitoring of certain diseases of the eye, especially those in which function is lost before the structure is changed 3,4 .”
Vahedian, Z., Fakhraie, G., Ghasemi, M., Azimi, A., & Tabatabaei, S. M. (2022) · Graefe s Archive for Clinical and Experimental Ophthalmology · doi:10.1007/s00417-022-05756-w · Cited by 2
“Electroretinographic studies with patterned stimulus have shown reduced amplitudes of the outer retina [12].”
BackgroundYuan, M. (2024) · Analog circuits and signal processing/Analog circuits and signal processing series · doi:10.1007/978-3-031-52834-7_7 · Cited by 2
Impact of Myopia on the Utility of the Photopic Negative Response Ratio for Glaucoma Assessment
Park, Y. G., Park, C. K., & Jung, K. I. (2025) · Journal of Clinical Medicine · doi:10.3390/jcm14030682 · Cited by 2
“Unlike pattern ERG, which requires refractive correction and good fixation, PhNR measurement is relatively independent of refractive errors, steady fixation control, and optical clarity [6,10].”
InfluentialChoroidal Thickness and Its Correlations with Ocular Parameters in Primary Open-Angle Glaucoma
Kutluksaman, B. (2019) · Beyoglu Eye Journal · doi:10.14744/bej.2019.86570 · Cited by 2
Zhang, Z., Wang, H., Li, W. S., Liu, Y., Xu, L., & Liu, J. (2025) · Experimental Eye Research · doi:10.1016/j.exer.2025.110327 · Cited by 1
Functional crosstalk between the lung and eye: a new frontier in chronic lung diseases
Lee, H., Taylor-Blair, H. C., Chellappan, D. K., Rubis, G. D., Paudel, K. R., Oliver, B. G. G., Dua, K., & Yeung, S. (2025) · Archives of Toxicology · doi:10.1007/s00204-025-04136-7 · Cited by 3
“…amplitude are indications of bipolar cell dysfunction, suggesting improper relaying of signals from photoreceptors to RGCs, resulting in overstimulation, and possible degeneration, of RGCs through excessive glutamate release (Boccuni & Fairless 2022; Lakshmanan et al. 2023; Wilsey & Fortune 2016).”
Update on the structure-function relationship in glaucoma
Wong, D., Chua, J., Hemelings, R., Tan, B., Zhang, C., Ling, T., Garhöfer, G., Popa‐Cherecheanu, A., Stalmans, I., & Schmetterer, L. F. (2026) · Survey of Ophthalmology · doi:10.1016/j.survophthal.2026.06.002 · Cited by 1
Michaud, L., Garon, M.-L., Forcier, P., & Diaconu, V. (2022) · Clinical ophthalmology · doi:10.2147/opth.s356245 · Cited by 1
“While the short-flash ERG assesses mostly the function of the photoreceptors and bipolar/Muller cells complex, the photopic negative response (PhNR) and pattern ERG (PERG), amongst other techniques, may be used to measure retinal ganglion cell function.(24) More specifically, in this study, two different electrophysio…”
MethodMeasuring the Full-Field Electroretinogram in Rodents
Lee, P. Y., Zhao, D. Y., Wong, V. H. Y., Hoang, A., Tran, K. K. N., van Koeverden, A. K., Afiat, B. C., Nguyen, C. T. O., & Bui, B. V. (2023) · Methods in molecular biology · doi:10.1007/978-1-0716-3409-7_14 · Cited by 1
Briefs on Evaluation Techniques for Glaucoma
Kong, X., & Sun, X. (2019) · Springer eBooks · doi:10.1007/978-981-13-2733-9_3
Early detection of glaucoma suspect by pattern electroretinogram
El-Shinawy, R. A., Hassan, H. M., Salman, A. G., & Elsbaay, M. (2019) · Journal of the Egyptian Ophthalmological Society · doi:10.4103/ejos.ejos_74_18
Visual field testing using VR headset
Kumal, A. (2020) · LUTPub (LUT University)
How to Reduce Error in Optic Nerve Head Examination
Ross, C. M., Kong, G. Y. X., Martin, K. R. G., & Coote, M. (2021) · Springer eBooks · doi:10.1007/978-981-33-6838-5_5
Glaucoma Visual Function Assessment
Eadie, B. D., Kwon, Y. H., & Shuba, L. M. (2020) · Springer eBooks · doi:10.1007/978-3-319-90495-5_166-1
El-Shazly, A. A. E.-F., Elsamkary, M., Badran, T. A. F., & Abdelgawad, R. H. A. (2020) · doi:10.21203/rs.2.21158/v1
“(12) The pattern reversal ERG (PERG) and the photopic negative response (PhNR) of the full-field ERG provide objective measures of retinal ganglion cell function.”
BackgroundElectrophysiological measures of optic nerve function
Afari, C. (2021) · UWSpace (University of Waterloo)
Incorporating Perimetry in Managing Glaucoma
Gandhi, M., & Patyal, S. (2021) · Springer eBooks · doi:10.1007/978-981-16-2601-2_2
Glaucoma Visual Function Assessment
Eadie, B. D., Kwon, Y. H., & Shuba, L. M. (2022) · Springer eBooks · doi:10.1007/978-3-030-42634-7_166
Design and analysis of an efficient glaucoma model for evaluation of pharmacological trials
Caballero, G., Villegas, N. Á., Cremonezzi, D., Campana, V., Palma, S. D., Allemandi, D. A., & Tártara, L. I. (2022) · Exploratory Animal and Medical Research · doi:10.52635/eamr/12.1.109-117
“Perhaps the use of higher stimulus intensities could have shown changes in this variable, as explained by Wilsey and Fortune (2016).”
BackgroundDaneshvar, R., & Nouri‐Mahdavi, K. (2023) · Elsevier eBooks · doi:10.1016/b978-0-323-88442-6.00015-7
Metadata
- Authors
- Wilsey, L. J., & Fortune, B.
- Affiliations
- Legacy Health (US)
- Corresponding author
- Fortune, Brad
- Venue
- Current Opinion in Ophthalmology
- Published
- 2016-03
- Volume
- 27
- Issue
- 2
- Pages
- 118-124
- ISSN
- 1040-8738 (ISSN-L)
- PMC
- PMC4698880
- OpenAlex
- W2409899358
- Semantic Scholar
- 225289cb32c0b42327b88e6069cba671a4c9c542
- Cited by
- 113
- References
- 72
- Citations by year
- 2026: 3 · 2025: 11 · 2024: 8 · 2023: 11 · 2022: 19 · 2021: 19 · 2020: 10 · 2019: 13 · 2018: 7 · 2017: 8 · 2016: 4
- FWCI
- 1.17
- Type
- journal article
- Language
- en
- Open access
- green
- www.ncbi.nlm.nih.gov
- Locations
- Current Opinion in Ophthalmology (publishedVersion)
- PubMed (publishedVersion)
- Europe PMC (PubMed Central) (acceptedVersion)
- PubMed Central (acceptedVersion)
- Funders
- National Eye Institute (R01EY019327)
- Topics
- Health Sciences › Medicine › Ophthalmology › Glaucoma and retinal disorders
- Health Sciences › Medicine › Ophthalmology › Retinal Development and Disorders
- Health Sciences › Medicine › Ophthalmology › Drug-Induced Ocular Toxicity
- Keywords
- electroretinogram, glaucoma diagnosis, photopic negative response, retinal ganglion cell function, retinal nerve fiber layer thinning, risk stratification, early glaucomatous damage
- MeSH terms
- Animals, Electroretinography, Glaucoma, Humans, Retina, Retinal Ganglion Cells, Visual Fields
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.