Automated Detection of Glaucoma From Topographic Features of the Optic Nerve Head in Color Fundus Photographs
The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
Objective: To describe and evaluate the performance of an automated CAD system for detection of glaucoma from color fundus photographs. Design and Setting: Color fundus photographs of 2252 eyes from 1126 subjects were collected from 2 centers: Aravind Eye Hospital, Madurai and Coimbatore, India. The images of 1926 eyes (963 subjects) were used to train an automated image analysis-based system, which was developed to provide a decision on a given fundus image. A total of 163 subjects were clinically examined by 2 ophthalmologists independently and their diagnostic decisions were recorded. The consensus decision was defined to be the clinical reference (gold standard). Fundus images of eyes with disagreement in diagnosis were excluded from the study. The fundus images of the remaining 314 eyes (157 subjects) were presented to 4 graders and their diagnostic decisions on the same were collected. The performance of the system was evaluated on the 314 images, using the reference standard. The sensitivity and specificity of the system and 4 independent graders were determined against the clinical reference standard. Results: The system achieved an area under receiver operating characteristic curve of 0.792 with a sensitivity of 0.716 and specificity of 0.717 at a selected threshold for the detection of glaucoma. The agreement with the clinical reference standard as determined by Cohen κ is 0.45 for the proposed system. This is comparable to that of the image-based decisions of 4 ophthalmologists. Conclusions and Relevance: An automated system was presented for glaucoma detection from color fundus photographs. The overall evaluation results indicated that the presented system was comparable in performance to glaucoma classification by a manual grader solely based on fundus image examination.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Prevalence of open-angle glaucoma and ocular hypertension in Latinos
Varma, R., Ying-Lai, M., Francis, B. A., Nguyen, B. B.-T., Deneen, J., Wilson, M. R., & Azen, S. P. (2004) · Ophthalmology · doi:10.1016/j.ophtha.2004.01.025 · Cited by 483
Cited by
Li, Z., He, Y., Keel, S., Meng, W., Chang, R. T., & He, M. (2018) · Ophthalmology · doi:10.1016/j.ophtha.2018.01.023 · Cited by 830
“First, most previous studies 30,31,33,34 used technology on feature extraction, which inevitably would introduce errors in the localization and segmentation that would lead to misalignment and misclassi fi cation.”
ResultDigital technology, tele-medicine and artificial intelligence in ophthalmology: A global perspective
Li, J.-P. O., Liu, H., Ting, D. S. J., Jeon, S., Chan, R. V. P., Kim, J. E., Sim, D. A., Thomas, P. B. M., Lin, H., Chen, Y., et al. (2021) · Progress in Retinal and Eye Research · doi:10.1016/j.preteyeres.2020.100900 · Cited by 626
“…focused on segmentation of the optic disc and cup based on the combination of feature extraction techniques and supervised or unsupervised ML (Almazroa et al., 2015), with AUC ranging from 0.792 to 0.887 (Singh et al., 2016; Chakrabarty et al., 2016; Issac et al., 2015; Annan et al., 2016).”
MethodInfluentialChristopher, M., Belghith, A., Bowd, C., Proudfoot, J. A., Goldbaum, M. H., Weinreb, R. N., Girkin, C. A., Liebmann, J. M., & Zangwill, L. M. (2018) · Scientific Reports · doi:10.1038/s41598-018-35044-9 · Cited by 328
Liu, H., Li, L., Wormstone, I. M., Qiao, C., Zhang, C., Liu, P., Li, S., Wang, H., Mou, D., Pang, R., et al. (2019) · JAMA Ophthalmology · doi:10.1001/jamaophthalmol.2019.3501 · Cited by 307
Metadata
- Authors
- Chakrabarty, L., Joshi, G. D., Chakravarty, A., Raman, G. V., Krishnadas, S. R., & Sivaswamy, J.
- Venue
- Journal of Glaucoma
- Published
- 2016-07
- Volume
- 25
- Issue
- 7
- Pages
- 590-597
- ISSN
- 1057-0829 (ISSN-L)
- OpenAlex
- W2172410134
- Cited by
- 36
- References
- 1
- FWCI
- 1.97
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Automated Detection of Glaucoma From Topographic Features of the Optic Nerve Head in Color Fundus Photographs. https://app.cochat.ai/papers/10.1097/ijg.0000000000000354
- The paper
- Chakrabarty, L., Joshi, G. D., Chakravarty, A., Raman, G. V., Krishnadas, S. R., & Sivaswamy, J. (2016). Automated Detection of Glaucoma From Topographic Features of the Optic Nerve Head in Color Fundus Photographs. Journal of Glaucoma. https://doi.org/10.1097/ijg.0000000000000354
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.