Evaluation of a Deep Learning System For Identifying Glaucomatous Optic Neuropathy Based on Color Fundus Photographs
Open accessThe DOI matches its Crossref record; 16 of the 17 references it cites were found in a registry or an index.
Abstract
Precis: Pegasus outperformed 5 of the 6 ophthalmologists in terms of diagnostic performance, and there was no statistically significant difference between the deep learning system and the “best case” consensus between the ophthalmologists. The agreement between Pegasus and gold standard was 0.715, whereas the highest ophthalmologist agreement with the gold standard was 0.613. Furthermore, the high sensitivity of Pegasus makes it a valuable tool for screening patients with glaucomatous optic neuropathy. Purpose: The purpose of this study was to evaluate the performance of a deep learning system for the identification of glaucomatous optic neuropathy. Materials and Methods: Six ophthalmologists and the deep learning system, Pegasus, graded 110 color fundus photographs in this retrospective single-center study. Patient images were randomly sampled from the Singapore Malay Eye Study. Ophthalmologists and Pegasus were compared with each other and to the original clinical diagnosis given by the Singapore Malay Eye Study, which was defined as the gold standard. Pegasus’ performance was compared with the “best case” consensus scenario, which was the combination of ophthalmologists whose consensus opinion most closely matched the gold standard. The performance of the ophthalmologists and Pegasus, at the binary classification of nonglaucoma versus glaucoma from fundus photographs, was assessed in terms of sensitivity, specificity and the area under the receiver operating characteristic curve (AUROC), and the intraobserver and interobserver agreements were determined. Results: Pegasus achieved an AUROC of 92.6% compared with ophthalmologist AUROCs that ranged from 69.6% to 84.9% and the “best case” consensus scenario AUROC of 89.1%. Pegasus had a sensitivity of 83.7% and a specificity of 88.2%, whereas the ophthalmologists’ sensitivity ranged from 61.3% to 81.6% and specificity ranged from 80.0% to 94.1%. The agreement between Pegasus and gold standard was 0.715, whereas the highest ophthalmologist agreement with the gold standard was 0.613. Intraobserver agreement ranged from 0.62 to 0.97 for ophthalmologists and was perfect (1.00) for Pegasus. The deep learning system took ∼10% of the time of the ophthalmologists in determining classification. Conclusions: Pegasus outperformed 5 of the 6 ophthalmologists in terms of diagnostic performance, and there was no statistically significant difference between the deep learning system and the “best case” consensus between the ophthalmologists. The high sensitivity of Pegasus makes it a valuable tool for screening patients with glaucomatous optic neuropathy. Future work will extend this study to a larger sample of patients.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
The cited source says what the claim attributes to it.
In the citing paper
“Twenty-five studies17,28,29,35,37,39,40,44–61 compared algorithm performance against healthcare professionals.”
From Diagnostic accuracy of deep learning in medical imaging: a systematic review and meta-analysis (2021) · cites this paper as [46]
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
A guideline of selecting and reporting intraclass correlation coefficients for reliability research
Koo, T. K., & Li, M. Y. (2016) · Journal of Chiropractic Medicine · doi:10.1016/j.jcm.2016.02.012 · Cited by 31,709 · cited 2×
“11 Similarly, the agreement varied between the 6 ophthalmologists and between them and the gold standard based on disc photography.”
BackgroundDeLong, E. R., DeLong, D. M., & Clarke-Pearson, D. L. (1988) · Biometrics · doi:10.2307/2531595 · Cited by 22,649
Global Prevalence of Glaucoma and Projections of Glaucoma Burden through 2040
Tham, Y.-C., Li, X., Wong, T. Y., Quigley, H. A., Aung, T., & Cheng, C.-Y. (2014) · Ophthalmology · doi:10.1016/j.ophtha.2014.05.013 · Cited by 7,159
Li, Z., He, Y., Keel, S., Meng, W., Chang, R. T., & He, M. (2018) · Ophthalmology · doi:10.1016/j.ophtha.2018.01.023 · Cited by 830 · cited 1×
“19 In addition to disease detection, AI systems can be used to establish normal examinations in ophthalmology.”
BackgroundThe coming of age of artificial intelligence in medicine
Patel, V. L., Shortliffe, E. H., Stefanelli, M., Szolovits, P., Berthold, M. R., Bellazzi, R., & Abu-Hanna, A. (2009) · Artificial Intelligence in Medicine · doi:10.1016/j.artmed.2008.07.017 · Cited by 625
Self-citationFoong, A. W. P., Saw, S.-M., Loo, J.-L., Shen, S., Loon, S.-C., Rosman, M., Aung, T., Tan, D. T. H., Tai, E. S., & Wong, T. Y. (2007) · Ophthalmic Epidemiology · doi:10.1080/09286580600878844 · Cited by 432
Christopher, M., Belghith, A., Bowd, C., Proudfoot, J. A., Goldbaum, M. H., Weinreb, R. N., Girkin, C. A., Liebmann, J. M., & Zangwill, L. M. (2018) · Scientific Reports · doi:10.1038/s41598-018-35044-9 · Cited by 328
Development of machine learning models for diagnosis of glaucoma
Kim, S. J., Cho, K. J., & Oh, S. (2017) · PLOS ONE · doi:10.1371/journal.pone.0177726 · Cited by 266
Development of a deep residual learning algorithm to screen for glaucoma from fundus photography
Shibata, N., Tanito, M., Mitsuhashi, K., Fujino, Y., Matsuura, M., Murata, H., & Asaoka, R. (2018) · Scientific Reports · doi:10.1038/s41598-018-33013-w · Cited by 249 · cited 1×
“16 However, these studies have not previously compared the performance of a deployed deep learning system to the performance of ophthalmologists for the same patients, nor compared the speed at which a diagnosis outcome could be determined from the photograph.”
ResultThe Current State of Teleophthalmology in the United States
Rathi, S., Tsui, E., Mehta, N., Zahid, S., & Schuman, J. S. (2017) · Ophthalmology · doi:10.1016/j.ophtha.2017.05.026 · Cited by 248 · cited 2×
“20 Remote screening allows increased access for underserved populations and earlier detection of ophthalmic disease.”
Background
Research works printed but not linked: 3
- Prediction of diseases via ocular imaging: The Singapore Retinal Archival and Analysis Imaging Network. T Y Wong, Inaugural Ocular Imaging Symposium. June 2008
- Annual International Conference of the IEEE. Buenos Aires, ArgentinaIEEEAugust 31, 2010-September 4, 2010. 2010
- Deep residual learning for image recognition. K He, X Zhang, S Ren, arXiv:1512.033852015arXiv preprint
Cited by
Diagnostic accuracy of deep learning in medical imaging: a systematic review and meta-analysis
Aggarwal, R., Sounderajah, V., Martin, G., Ting, D. S. W., Karthikesalingam, A., King, D., Ashrafian, H., & Darzi, A. (2021) · npj Digital Medicine · doi:10.1038/s41746-021-00438-z · Cited by 946
Systematic reviews of machine learning in healthcare: a literature review
Kolasa, K., Admassu, B. Y., Hołownia-Voloskova, M. E., Kędzior, K. J., Poirrier, J., & Perni, S. (2023) · Expert Review of Pharmacoeconomics & Outcomes Research · doi:10.1080/14737167.2023.2279107 · Cited by 121
Explainable Machine Learning Model for Glaucoma Diagnosis and Its Interpretation
Oh, S., Park, Y., Cho, K. J., & Kim, S.-J. (2021) · Diagnostics · doi:10.3390/diagnostics11030510 · Cited by 103
“Among them, there are many papers that diagnose glaucoma by detecting increased CDR or loss of neuro-retinal rim in the disc using fundus photography [28].”
BackgroundA deep learning approach in diagnosing fungal keratitis based on corneal photographs
Kuo, M., Hsu, B. W., Yin, Y.-K., Fang, P., Lai, H., Chen, A., Yu, M.-S., & Tseng, V. S. M. (2020) · Scientific Reports · doi:10.1038/s41598-020-71425-9 · Cited by 85
Artificial intelligence in glaucoma: opportunities, challenges, and future directions
Huang, X., Islam, M. R., Prome, S. A., Ahmed, F., Kazami, E., Serhan, H. A. A., Abd-Alrazaq, A. A., & Yousefi, S. (2023) · BioMedical Engineering OnLine · doi:10.1186/s12938-023-01187-8 · Cited by 83
“Al-Aswad et al. [289] evaluated the performance of Pegasus (an AI system based on deep learning) in glaucoma screening based on color fundus photographs by comparing with six ophthalmologists.”
BackgroundZhu, Y., Salowe, R., Chow, C., Li, S., Bastani, O., & O’Brien, J. M. (2024) · Bioengineering · doi:10.3390/bioengineering11020122 · Cited by 83
Ling, X. C., Chen, H. S.-L., Yeh, P., Cheng, Y.-C., Huang, C.-Y., Shen, S., & Lee, Y. (2025) · Biomedicines · doi:10.3390/biomedicines13020420 · Cited by 85
“Other ensemble methods for image analysis included modules such as XGBoost, random forest, gradient boosting, and many more [19”
Gunasekeran, D. V., & Wong, T. Y. (2020) · Asia-Pacific Journal of Ophthalmology · doi:10.1097/01.apo.0000656984.56467.2c · Cited by 75
Role of artificial intelligence and machine learning in ophthalmology
Akkara, J., & Kuriakose, A. (2019) · Kerala Journal of Ophthalmology · doi:10.4103/kjo.kjo_54_19 · Cited by 68
“[47] Netra.AI (Leben Care Technologies Pte., Ltd.) is another AI that evaluates glaucomatous fundus photographs [Figure 4].”
BackgroundWu, J., Nishida, T., Weinreb, R. N., & Lin, J. (2021) · American Journal of Ophthalmology · doi:10.1016/j.ajo.2021.12.008 · Cited by 60
The upcoming role of Artificial Intelligence (AI) for retinal and glaucomatous diseases
Desideri, L. F., Rutigliani, C., Corazza, P., Nastasi, A., Roda, M., Nicolò, M., Traverso, C. E., & Vagge, A. (2022) · Journal of Optometry · doi:10.1016/j.optom.2022.08.001 · Cited by 54
“57 Li et al. described a DL algorithm with a comparable performance in detecting glaucoma from fundus photography, with a sensitivity of 95.6% and speci fi city of 92%.”
MethodInfluentialDiagnostic Accuracy of Artificial Intelligence in Glaucoma Screening and Clinical Practice
Chaurasia, A. K., Greatbatch, C. J., & Hewitt, A. W. (2022) · Journal of Glaucoma · doi:10.1097/ijg.0000000000002015 · Cited by 54
“For instance, 2 studies used the same data set (EODAT), which contributed approximately a third of all fundus images to their data set, 34,95 introducing some bias into our meta-analysis.”
BackgroundMethodThe AI revolution in glaucoma: Bridging challenges with opportunities
Li, F., Wang, D., Yang, Z., Zhang, Y., Jiang, J., Liu, X., Kong, K., Zhou, F., Tham, C. C. Y., Medeiros, F. A., et al. (2024) · Progress in Retinal and Eye Research · doi:10.1016/j.preteyeres.2024.101291 · Cited by 49
Artificial Intelligence and Advanced Technology in Glaucoma: A Review
Tonti, E., Tonti, S., Mancini, F., Bonini, C., Spadea, L., D’Esposito, F., Gagliano, C., Musa, M., & Zeppieri, M. (2024) · Journal of Personalized Medicine · doi:10.3390/jpm14101062 · Cited by 55
Applications of Artificial Intelligence and Deep Learning in Glaucoma
Chen, D. K., Ran, E. A., Tan, T. F., Ramachandran, R., Li, F., Cheung, C. Y.-L., Yousefi, S., Tham, C. C. Y., Ting, D. S. W., Zhang, X., et al. (2023) · Asia-Pacific Journal of Ophthalmology · doi:10.1097/apo.0000000000000596 · Cited by 40
“Although there are many manufacturers, the most commonly used pe-rimeter is the Humphrey Field Analyzer (Carl Zeiss Meditec) and most commonly performed tests assess the central 30, 24, or 10 degrees of vision.”
BackgroundMethodSelf-citationIntelligence artificielle et glaucome : une revue de la littérature
Bunod, R., Augstburger, E., Brasnu, E., Labbé, A., & Baudouin, C. (2022) · Journal Français d Ophtalmologie · doi:10.1016/j.jfo.2021.11.002 · Cited by 36
Artificial Intelligence for Glaucoma
Al‐Aswad, L. A., Ramachandran, R., Schuman, J. S., Medeiros, F. A., Eydelman, M. B., Abràmoff, M. D., Antony, B. J., Boland, M. V., Chauhan, B. C., Chiang, M. F., et al. (2022) · Ophthalmology Glaucoma · doi:10.1016/j.ogla.2022.02.010 · Cited by 34
Self-citationRamesh, P. V., Subramaniam, T., Ray, P., Devadas, A. K., Ramesh, S. V., Ansar, S. M., Ramesh, M., Rajasekaran, R., & Parthasarathi, S. (2022) · Indian Journal of Ophthalmology · doi:10.4103/ijo.ijo_2583_21 · Cited by 37
Buisson, M., Navel, V., Labbé, A., Watson, S. L., Baker, J. S., Murtagh, P. J., Chiambaretta, F., & Dutheil, F. (2021) · Clinical and Experimental Ophthalmology · doi:10.1111/ceo.14000 · Cited by 31
“25,28,29 No other information was given regarding ophthalmologists, such as age, sex, or years of experience.”
BackgroundMethodInfluentialAl‐Aswad, L. A., Elgin, C. Y., Patel, V., Popplewell, D., Gopal, K., Gong, D. A., Thomas, Z., Joiner, D. B., Chu, C.-K., Walters, S. P., et al. (2021) · Asia-Pacific Journal of Ophthalmology · doi:10.1097/apo.0000000000000416 · Cited by 30
Self-citationGomes, R. F. T., Schuch, L. F., Martins, M. D., Honório, E. F., de Figueiredo, R. M., Schmith, J., Machado, G. N., & Carrard, V. C. (2023) · Journal of Imaging Informatics in Medicine · doi:10.1007/s10278-023-00775-3 · Cited by 31
“…in the identification of visual patterns and automated classification of clinic images [20, 21], including the classification of ophthalmic diseases [16, 17, 22–25], skin lesions [4, 5, 21, 26–29], and change genetic/phenotypic lesions [30], among others, with high sensitivity and specificity.”
BackgroundInfluentialSarayar, R., Lestari, Y. D., Setio, A. A. A., & Sitompul, R. (2023) · Frontiers in Public Health · doi:10.3389/fpubh.2023.1239231 · Cited by 31
Multi-modality fusion learning for the automatic diagnosis of optic neuropathy
Cao, Z., Sun, C., Wang, W., Zheng, X., Wu, J., & Gao, H. (2020) · Pattern Recognition Letters · doi:10.1016/j.patrec.2020.12.009 · Cited by 25
Ophthalmic imaging for the diagnosis and monitoring of glaucoma: A review
Elgin, C. Y., Chen, D. K., & Al‐Aswad, L. A. (2022) · Clinical and Experimental Ophthalmology · doi:10.1111/ceo.14044 · Cited by 27
Self-citationPrecision Medicine in Glaucoma: Artificial Intelligence, Biomarkers, Genetics and Redox State
Fea, A. M., Ricardi, F., Novarese, C., Cimorosi, F., Vallino, V., & Boscia, G. (2023) · International Journal of Molecular Sciences · doi:10.3390/ijms24032814 · Cited by 26
Artificial intelligence in clinical education in ophthalmology: a systematic review
Yuan, L., Kang, D., Dong, X., Liu, L., Grzybowski, A. E., & Jin, K. (2025) · Visual Neuroscience · doi:10.48130/vns-0025-0025 · Cited by 21
Telehealth and Screening Strategies in the Diagnosis and Management of Glaucoma
Wong, S. H., & Tsai, J. C. (2021) · Journal of Clinical Medicine · doi:10.3390/jcm10163452 · Cited by 18
Can deep learning revolutionize clinical understanding and diagnosis of optic neuropathy?
Subramaniam, M. D., Abishek Kumar, B., Chirayath, R. B., Nair, A. P., Iyer, M., & Vellingiri, B. (2021) · Artificial Intelligence in the Life Sciences · doi:10.1016/j.ailsci.2021.100018 · Cited by 19
Vali, M., Mohammadi, M., Zarei, N., Samadi, M., Atapour–Abarghouei, A., Supakontanasan, W., Suwan, Y., Subramanian, P. S., Miller, N. R., Kafieh, R., et al. (2023) · American Journal of Ophthalmology · doi:10.1016/j.ajo.2023.02.016 · Cited by 17
Hong, R. K., Kim, M., Hong, E. H., Kang, M. H., Shin, Y. U., Park, H.-C., & Hwang, S. (2025) · Canadian Journal of Ophthalmology · doi:10.1016/j.jcjo.2025.07.008 · Cited by 12
The use of deep learning technology for the detection of optic neuropathy
Li, M., & Wan, C. (2021) · Quantitative Imaging in Medicine and Surgery · doi:10.21037/qims-21-728 · Cited by 11
“(38) graded 110 color fundus photographs using the DLS Pegasus.”
MethodNguyen, V., Iyengar, S., Rasheed, H., Apolo, G., Li, Z., Kumar, A., Nguyen, H., Bohner, A. D., Bolo, K. A., Dhodapkar, R. M., et al. (2025) · Ophthalmology Science · doi:10.1016/j.xops.2025.100751 · Cited by 11
Ramesh, P. V., Ramesh, S. V., Devadas, A. K., Ray, P., Tamilselvan, S., Parthasarathi, S., Ramesh, M. K., & Rajasekaran, R. (2021) · Indian Journal of Ophthalmology · doi:10.4103/ijo.ijo_1820_21 · Cited by 11
Artificial Intelligence in Ocular Drug Delivery: Precision Drug Delivery's New Horizon
Srivastava, V., Yadav, P., Yadav, A., & Parashar, P. (2025) · AAPS PharmSciTech · doi:10.1208/s12249-025-03271-9 · Cited by 10
“Working on same line of principle numerous scientists have developed various AI model to detect and classify glaucoma using optic disc, fundus images [112, 113].”
HUANG, A. S., Fam, A., ZHAO, H., PAULESCU, N., Fabczak-Kubicka, A., Wiggs, J. L., Zebardast, N., Friedman, D. S., Do, R., Aziz, K., et al. (2025) · American Journal of Ophthalmology · doi:10.1016/j.ajo.2025.11.046 · Cited by 7
POURJAVAN, S., Bourguignon, G.-H., Marinescu-George, C., Otjacques, L., & Boschi, A. (2024) · Clinical ophthalmology · doi:10.2147/opth.s492872 · Cited by 7
Guo, M., Gong, D., & Yang, W. (2024) · Frontiers in Medicine · doi:10.3389/fmed.2024.1489139 · Cited by 7
Self-citationMulti-Stage Ensemble-Based System for Glaucomatous Optic Neuropathy Diagnosis in Fundus Images
Vásquez-Rochín, C. A., Rosas, M. E. M., de Ávila, H. C., Romo-Cárdenas, G. S., Luque-Morales, P. A., & Miranda-Velasco, M. M. (2023) · Electronics · doi:10.3390/electronics12041046 · Cited by 6
Classification of Ocular Diseases Related to Diabetes Using Transfer Learning
Sbaï, A., Oukhouya, L., & Touil, A. (2023) · International Journal of Online and Biomedical Engineering (iJOE) · doi:10.3991/ijoe.v19i11.40997 · Cited by 5
Artificial intelligence in ophthalmology: A new era is beginning
Panda, B. B., Thakur, S., Mohapatra, S., & Parida, S. (2021) · Artificial Intelligence in Medical Imaging · doi:10.35711/aimi.v2.i1.5 · Cited by 3
Bali, J., & Bali, O. (2023) · Delhi Journal of Ophthalmology · doi:10.4103/dljo.dljo_135_23 · Cited by 3
Utilizing Artificial Intelligence for Enhancing Glaucoma Care
Gupta, V., & Dada, T. (2025) · JOURNAL OF CURRENT GLAUCOMA PRACTICE · doi:10.5005/jp-journals-10078-1472 · Cited by 2
“9,14,15 The Indian Medios model that works offline has shown sensitivity and specificity of 93.7 and 85.6%, respectively, in the detection of referable glaucoma and had high repeatability.”
InfluentialThe Use of Artificial Intelligence in the Diagnosis of Eye Diseases - a Review
Siwik, M., Waszak, J., Mazur, U., Ogonowska, P., Bazarewicz, J., Kubuj, C., Dmowski, D., Michalska, A. T., Świda, M., & Adaśko, G. (2025) · Quality in Sport · doi:10.12775/qs.2025.45.66568 · Cited by 2
Application of Artificial Intelligence in Glaucoma Diagnosis – a Literature Review
Siwik, M., Nałęcz, N., Jankowska, Z., Laudencka, A., Kaźmierczak, K., & Kałużny, B. J. (2026) · Ophthalmology · doi:10.5114/oku/215549 · Cited by 1
Artificial intelligence in glaucoma: Current perspectives and future directions
Mishra, P., Panda, B. B., & Singh, M. (2025) · Odisha Journal of Ophthalmology · doi:10.4103/odjo.odjo_6_25 · Cited by 1
Umetna inteligenca v obravnavi bolnika z boleznijo mrežnice
Koce, M., Mekjavič, P. J., Urbančič, M., Pompe, M. T., & Petrovič, M. G. (2022) · Slovenian Medical Journal · doi:10.6016/zdravvestn.3259 · Cited by 1
The Current State of Artificial Intelligence in Neuro-Ophthalmology. A Review
Lapka, M., & Straňák, Z. (2023) · Czech and Slovak Ophthalmology · doi:10.31348/2023/33 · Cited by 1
Wu, X., Li, W., Wang, S., Dong, F., Zhang, S., & Yang, W. (2023) · doi:10.2196/preprints.50485
Using Deep Learning for the Detection of Ocular Diseases Caused by Diabetes
Sbaï, A., Oukhouya, L., & Touil, A. (2023) · Lecture notes on data engineering and communications technologies · doi:10.1007/978-3-031-36258-3_10
Harnessing the power of artificial intelligence for glaucoma diagnosis and treatment
Akkara, J. (2024) · Kerala Journal of Ophthalmology · doi:10.4103/kjo.kjo_69_24
Deep Learning based Safe Car Driving Experience Using Glaucoma Grading
Patel, T., Kumar, P., Vachhani, A., Tanwar, S., & Gupta, R. (2025) · International Conference on Artificial Intelligence and Machine Vision (AIMV) · doi:10.1109/aimv66517.2025.11203360
“CNNs effectively capture clinical features such as the cup-to-disc ratio and segment the disc, rim, and cup regions [4].”
Li, S., Salowe, R., Lee, R., Ying, G., Lee, I., O'Brien, J., & Bastani, O. (2026) · npj Digital Medicine · doi:10.1038/s41746-025-02318-2
Gasimov, E. M., & Gasimova, J. E. (2026) · Azerbaijan Journal of Ophthalmology · doi:10.71110/ajo79102026180156143153
Advances in Optical Coherence Tomography for Glaucoma Diagnosis and Monitoring
Silveira, V. D. ́., Zambrano, R., Lavinsky, F., Wollstein, G., & Schuman, J. S. (2026) · Advances in Ophthalmology and Optometry · doi:10.1016/j.yaoo.2026.04.002
Deep Learning for Automated Glaucoma Detection: A Multi-Modal Biomarker Fusion Approach
S, V. R., & Srinivas, C. (2025) · International Conference on Emerging Research in Computational Science (ICERCS) · doi:10.1109/icercs65898.2025.11581272
“[7,8] In order to combat these limitations, multi-modal approaches were examined.”
Yıldırım, M., Karaduman, M., Kızıloluk, S., Çetintaş, D., & Aksoy, A. (2026) · Physical and Engineering Sciences in Medicine · doi:10.1007/s13246-026-01771-x
“The researchers achieved a high sen - sitivity of 83.7% and specificity of 88.2% with glaucoma deep learning (PEGASUS) based on fundus images [ 27 ].”
InfluentialLiang, M., Lu, J., & Qin, C. (2026) · Graefe s Archive for Clinical and Experimental Ophthalmology · doi:10.1007/s00417-026-07433-8
Artificial intelligence for glaucoma detection in highly myopic eyes: A review
Wu, M., Xing, Y., Wu, H., Wang, M., & Zhou, Y. (2026) · Neurocomputing · doi:10.1016/j.neucom.2026.135286
Alharbi, M. M., Alharbi, E. M., Alsalamah, A. S., Asiri, H., Beati, N., AlAtawi, R., & Arafat, A. A. (2026) · Journal of Clinical Medicine · doi:10.3390/jcm15207957
Metadata
- Authors
- Al-Aswad, L. A., Kapoor, R., Chu, C. K., Walters, S., Gong, D., Garg, A., Gopal, K., Patel, V., Sameer, T., Rogers, T. W., Nicolas, J., De Moraes, G. C., & Moazami, G.
- Affiliations
- Columbia University Medical Center, Harkness Eye Institute, New York, NY
- Columbia University Irving Medical Center (US)
- Visulytix Ltd
- Corresponding author
- Kapoor, Rahul
- Chu, Chia Kai
- Walters, Stephen
- Gong, Dan
- Gopal, Kalashree
- Patel, Vipul
- Moazami, Golnaz
- Venue
- Journal of Glaucoma
- Published
- 2019-06-21
- Volume
- 28
- Issue
- 12
- Pages
- 1029-1034
- ISSN
- 1057-0829 (ISSN-L)
- OpenAlex
- W2955420986
- Semantic Scholar
- 499b9a9ba186934a09228934b82dc90ac33a81fa
- Cited by
- 59
- References
- 17
- Citations by year
- 2026: 8 · 2025: 10 · 2024: 7 · 2023: 14 · 2022: 6 · 2021: 10 · 2020: 3 · 2019: 1
- FWCI
- 3.31
- Type
- journal article
- Language
- en
- Open access
- hybrid
- doi.org
- Licence
- cc-by
- Locations
- Journal of Glaucoma (publishedVersion, cc-by)
- PubMed (publishedVersion)
- Funders
- National Eye Institute (R21EY029605)
- Topics
- Health Sciences › Medicine › Radiology, Nuclear Medicine and Imaging › Retinal Imaging and Analysis
- Health Sciences › Medicine › Ophthalmology › Glaucoma and retinal disorders
- Health Sciences › Medicine › Ophthalmology › Ophthalmology and Visual Health Research
- Keywords
- glaucomatous optic neuropathy, glaucoma diagnosis, color fundus images, deep learning, Pegasus, ophthalmologist comparison, interobserver agreement, intraobserver agreement, glaucoma screening, Singapore Malay Eye Study, diagnostic accuracy, automated diagnosis, intraocular pressure, optic disc margin, cup-to-disc ratio
- MeSH terms
- Ophthalmologists, Deep Learning, Adult, Aged, Diagnosis, Computer-Assisted, Diagnostic Techniques, Ophthalmological, Female, Glaucoma, Open-Angle, Humans, Intraocular Pressure, Male, Middle Aged, Optic Disk, Optic Nerve Diseases, Photography, Retrospective Studies, ROC Curve, Sensitivity and Specificity, Observer Variation, Area Under Curve
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.