CoChat

Circulating Tumor Microemboli Diagnostics for Patients with Non–Small-Cell Lung Cancer

Open access
Carlsson, Anders, Nair, Viswam S., Luttgen, Madelyn S., Keu, Khun Visith, Horng, George, Vasanawala, Minal, Kolatkar, Anand, Jamali, Mehran, Iagaru, Andrei H., Kuschner, Ware, Loo, Billy W., Shrager, Joseph B., Bethel, Kelly, Hoh, Carl K., Bazhenova, Lyudmila, Nieva, Jorge, Kuhn, Peter, Gambhir, Sanjiv S. · 2014 · Journal of Thoracic Oncology
Cited by 76

The DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.

Abstract

Introduction: Circulating tumor microemboli (CTM) are potentially important cancer biomarkers, but using them for cancer detection in early-stage disease has been assay limited. We examined CTM test performance using a sensitive detection platform to identify stage I non–small-cell lung cancer (NSCLC) patients undergoing imaging evaluation. Methods: First, we prospectively enrolled patients during 18F-FDG PET-CT imaging evaluation for lung cancer that underwent routine phlebotomy where CTM and circulating tumor cells (CTCs) were identified in blood using nuclear (DAPI), cytokeratin (CK), and CD45 immune-fluorescent antibodies followed by morphologic identification. Second, CTM and CTC data were integrated with patient (age, gender, smoking, and cancer history) and imaging (tumor diameter, location in lung, and maximum standard uptake value [SUVmax]) data to develop and test multiple logistic regression models using a case-control design in a training and test cohort followed by cross-validation in the entire group. Results: We examined 104 patients with NSCLC, and the subgroup of 80 with stage I disease, and compared them to 25 patients with benign disease. Clinical and imaging data alone were moderately discriminating for all comers (Area under the Curve [AUC] = 0.77) and by stage I disease only (AUC = 0.77). However, the presence of CTM combined with clinical and imaging data was significantly discriminating for diagnostic accuracy in all NSCLC patients (AUC = 0.88, p value = 0.001) and for stage I patients alone (AUC = 0.87, p value = 0.002). Conclusion: CTM may add utility for lung cancer diagnosis during imaging evaluation using a sensitive detection platform.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1097/jto.0000000000000235

Cites

4 of 4 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 4 references

Cited by

See all 76

Metadata

Authors
Carlsson, A., Nair, V. S., Luttgen, M. S., Keu, K. V., Horng, G., Vasanawala, M., Kolatkar, A., Jamali, M., Iagaru, A. H., Kuschner, W., Loo, B. W., Shrager, J. B., Bethel, K., Hoh, C. K., Bazhenova, L., Nieva, J., Kuhn, P., & Gambhir, S. S.
Venue
Journal of Thoracic Oncology
Publisher
Elsevier BV
Published
2014-08
Volume
9
Issue
8
Pages
1111-1119
ISSN
1556-0864 (ISSN-L)
OpenAlex
W2003069503
Cited by
76
References
4
FWCI
6.30
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Circulating Tumor Microemboli Diagnostics for Patients with Non–Small-Cell Lung Cancer. https://app.cochat.ai/papers/10.1097/jto.0000000000000235
The paper
Carlsson, A., Nair, V. S., Luttgen, M. S., Keu, K. V., Horng, G., Vasanawala, M., Kolatkar, A., Jamali, M., Iagaru, A. H., Kuschner, W., Loo, B. W., Shrager, J. B., Bethel, K., Hoh, C. K., Bazhenova, L., Nieva, J., Kuhn, P., & Gambhir, S. S. (2014). Circulating Tumor Microemboli Diagnostics for Patients with Non–Small-Cell Lung Cancer. Journal of Thoracic Oncology. https://doi.org/10.1097/jto.0000000000000235

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.