CoChat

Acoustic Transmission Characteristics of a Eustachian Tube Volitionally Opened in Two Living Subjects

Amoako-Tuffour, Yaw, Jufas, Nicholas, Quach, Jack, Le, Lisa, Earle, Guy, Kotiya, Akhilesh A., Bance, Manohar · 2016 · Otology & Neurotology
Cited by 6

The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.

Abstract

OBJECTIVE: To assess the acoustic transmission characteristics of the Eustachian tube (ET) in living subjects in verified patent and closed ET states to facilitate the detection and quantification of ET function using acoustic measures such as sonotubometry. PATIENTS: The two subjects in this study had no history of ear disease nor previous ear surgery and were capable of volitionally opening and closing their ET. INTERVENTIONS: Tympanometry and otologic examinations were used to confirm ET patent and closed states by observing tympanic membrane movement with respiration and by acoustic immitance measurements during forced respiration. A series of 500-ms long chirps containing frequencies from 100 Hz to 10 kHz were introduced into the nasal cavity during both ET states and recorded by microphones in both the contralateral naris and external auditory canal. MAIN OUTCOME MEASURES: Acoustic energy transmission through the ET across the 0.1 to 10 kHz frequency range in the closed state versus the patent state. RESULTS: An increase in acoustic energy transmission occurs across the frequencies of 1 to 4 kHz between the closed and patent ET states, particularly in frequencies below 2.5 kHz. CONCLUSIONS: Results support sonotubometry as a potential diagnostic tool for ET dysfunction. Acoustic differences between the ET states manifest as a general increase in transmitted signal amplitude. Characterizing the acoustic properties in the verified patent and closed ET states allows investigators to more reliably interpret sonotubometric tests of ET function.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1097/mao.0000000000001130

Cites

2 of 2 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Research works printed but not linked: 14

  1. Bluestone, 1996, Pathogenesis of otitis media: role of eustachian tube, Pediatr Infect Dis J, 15, 281, 10.1097/00006454-199604000-00002 · DOI · Paper page
  2. Ohta, 2009, Eustachian tube function and habitual sniffing in middle ear cholesteatoma, Otol Neurotol, 30, 48, 10.1097/MAO.0b013e31818de5b3 · DOI
  3. Tsuji, 2002, Bilateral cholesteatoma and habitual sniffing, Auris Nasus Larynx, 29, 111, 10.1016/S0385-8146(01)00146-8 · doi:10.1016/s0385-8146(01)00146-8
  4. Jonathan, 1986, Comparison of sonotubometry with tympanometry to assess Eustachian tube function in adults, Br J Audiol, 20, 231, 10.3109/03005368609079020 · DOI
  5. Henry, 1993, Patulous eustachian tube identification using tympanometry, J Am Acad Audiol, 4, 53
  6. Smith, 2015, Tests of Eustachian tube function: a review, Clin Otolaryngol, 40, 300, 10.1111/coa.12428 · DOI
  7. Uzun, 2000, Use of the nine-step inflation/deflation test as a predictor of middle ear barotrauma in sports scuba divers, Br J Audiol, 34, 153, 10.3109/03005364000000125 · DOI
  8. Bluestone, 1981, Current clinical methods, indications and interpretation of eustachian tube function tests, Ann Otol Rhinol Laryngol, 90, 552, 10.1177/000348948109000608 · DOI · Paper page
  9. Virtanen, 1978, Sonotubometry: an acoustical method for objective measurement of auditory tubal opening, Acta Otolaryngol, 86, 93, 10.3109/00016487809124724 · DOI · Paper page
  10. Murti, 1979, Sonometric evaluation of eustachian tube function using broadband stimuli, Ann Otol Rhinol Laryngol Suppl, 89, 178, 10.1177/00034894800890S342 · DOI
  11. Hori, 2006, Audiometry with nasally presented masking noise: novel diagnostic method for patulous eustachian tube, Otol Neurotol, 27, 596, 10.1097/01.mao.0000226301.21080.1c · DOI
  12. Di Martino, 2010, Evaluation of Eustachian tube function with perfect sequences: technical realization and first clinical results, Eur Arch Otorhinolaryngol, 267, 367, 10.1007/s00405-009-1074-9 · DOI
  13. Swarts, 2015, A method to assess the accuracy of sonotubometry for detecting Eustachian tube openings, Eur Arch Otorhinolaryngol, 272, 2111, 10.1007/s00405-014-3031-5 · DOI
  14. Paradis, 2015, Assessment of nasal-noise masking audiometry as a diagnostic test for patulous Eustachian tube, Otol Neurotol, 36, e36, 10.1097/MAO.0000000000000696 · DOI

Cited by

See all 6

Metadata

Authors
Amoako-Tuffour, Y., Jufas, N., Quach, J., Le, L., Earle, G., Kotiya, A. A., & Bance, M.
Venue
Otology & Neurotology
Published
2016-09
Volume
37
Issue
8
Pages
1055-1058
ISSN
1531-7129
Cited by
6
References
2
Language
en

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.