Sodium citrate vacuum tubes validation: preventing preanalytical variability in routine coagulation testing
The DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.
Abstract
Sometimes in-vitro diagnostic devices (e.g. blood collection tubes) are not validated before use or when the producer's brand is changed. The aim of this study was to validate five brands of sodium citrate vacuum tubes. Blood specimens from 50 volunteers were collected in five different tube brands (I: Venosafe, II: VACUETTE, III: BD Vacutainer, IV: LABOR IMPORT and V: S-Monovette). Routine coagulation tests [activated partial thromboplastin time (aPTT), prothrombin time (PT), and fibrinogen (FIB)] were performed on ACL TOP instrument using HemosIL reagents. The significance of the differences between samples was assessed by paired Student's t-test, set at P < 0.005. Significant differences were observed for: PT when comparing I vs. II, I vs. III, I vs. V, II vs. III, II vs. IV, II vs. V, III vs. IV, III vs. V and IV vs. V; aPTT when comparing I vs. II, I vs. III, I vs. IV, II vs. IV, III vs. IV and IV vs. V. No differences were observed among brands for FIB determination. We suggest that every laboratory management should both standardize the procedures and frequently evaluate the quality of in-vitro diagnostic devices.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Current databases on biological variation: pros, cons and progress
C. Ricós, V. A. (1999) · Scandinavian Journal of Clinical and Laboratory Investigation · doi:10.1080/00365519950185229 · Cited by 987
Lima-Oliveira, G., Lippi, G., Salvagno, G. L., Montagnana, M., Pitanguiera Manguera, C. L., Sumita, N. M., Picheth, G., Guidi, G. C., & Scartezini, M. (2011) · Biochemia Medica · doi:10.11613/bm.2011.024 · Cited by 56
Self-citationLIMA‐OLIVEIRA, G., LIPPI, G., SALVAGNO, G. L., MONTAGNANA, M., SCARTEZINI, M., GUIDI, G. C., & PICHETH, G. (2011) · International Journal of Laboratory Hematology · doi:10.1111/j.1751-553x.2011.01305.x · Cited by 46
Self-citationElimination of the venous stasis error for routine coagulation testing by transillumination
Lima-Oliveira, G., Salvagno, G. L., Lippi, G., Montagnana, M., Scartezini, M., Picheth, G., & Guidi, G. C. (2011) · Clinica Chimica Acta · doi:10.1016/j.cca.2011.04.008 · Cited by 38
Self-citation
Cited by
Lima-Oliveira, G., Volanski, W., Lippi, G., Picheth, G., & Guidi, G. C. (2017) · Scandinavian Journal of Clinical and Laboratory Investigation · doi:10.1080/00365513.2017.1295317 · Cited by 117
Self-citationIncorrect order of draw could be mitigate the patient safety: a phlebotomy management case report
Lima-Oliveira, G., Lippi, G., Salvagno, G. L., Montagnana, M., Picheth, G., & Guidi, G. C. (2013) · Biochemia Medica · doi:10.11613/bm.2013.026 · Cited by 33
“vacuum tubes and syringes) have different performances in routine laboratory tests and that changes in the brands can increase laboratory variability (19-23).”
BackgroundSelf-citationCould light meal jeopardize laboratory coagulation tests?
Lima-Oliveira, G., Salvagno, G. L., Lippi, G., Danese, E., Gelati, M., Montagnana, M., Picheth, G., & Guidi, G. C. (2014) · Biochemia Medica · doi:10.11613/bm.2014.036 · Cited by 30
“Moreover, poor control and standardization of the preanalytical phase in the whole testing process may influence the reliability of coagulation testing in the following points: i) phlebotomy procedure (21-23); ii) venous stasis (11,24): iii) vacuum tube used for blood collection by venipuncture (25).”
BackgroundSelf-citationGuidance on the critical shortage of sodium citrate coagulation tubes for hemostasis testing
Gosselin, R. C., Bowyer, A., Favaloro, E. J., Johnsen, J. M., Lippi, G., Marlar, R. A., Neeves, K., & Rollins‐Raval, M. A. (2021) · Journal of Thrombosis and Haemostasis · doi:10.1111/jth.15514 · Cited by 25
Self-citationLima-Oliveira, G., Lippi, G., Salvagno, G. L., Brocco, G., Gaino, S., Dima, F., Volaski, W., Rego, F. G., Picheth, G., & Guidi, G. C. (2014) · Biopreservation and Biobanking · doi:10.1089/bio.2013.0043 · Cited by 22
Self-citation
Metadata
- Authors
- Lima-Oliveira, G., Lippi, G., Salvagno, G. L., Montagnana, M., Picheth, G., & Guidi, G. C.
- Venue
- Blood Coagulation & Fibrinolysis
- Published
- 2013-04
- Volume
- 24
- Issue
- 3
- Pages
- 252-255
- ISSN
- 0957-5235 (ISSN-L)
- OpenAlex
- W2081104365
- Cited by
- 33
- References
- 4
- FWCI
- 2.08
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.