The DOI matches its Crossref record.
Accuracy validation of the Microlife 3AS1-2 blood pressure device in a pregnant population with low blood pressure
Abstract
OBJECTIVE: To assess the accuracy of the Microlife 3AS1-2 blood pressure (BP) device in pregnant women with low BP to investigate suitability for hypotensive detection in low-income and middle-income countries. METHODS: A prospective observational study was carried out evaluating the Microlife 3AS1-2, a hand-held, upper-arm, semiautomated BP device, according to British Hypertension Society (BHS) protocol methods. Thirty (stable) pregnant women with a clinical systolic BP less than 100 mmHg and/or diastolic BP less than 60 mmHg were recruited from antenatal wards and clinics and their BP was measured by three trained observers at a district-level hospital in South Africa. Accuracy was assessed according to the BHS grading criteria (A/B=pass) and the ANSI/AAMI/ISO standard for mean difference and SD (≤5±8 mmHg). RESULTS: The device achieved an A/A grade according to the BHS grading criteria. The mean difference±SD between the observer and the test device was 0.5±6.2 and 1.3±5.4 mmHg for systolic and diastolic BP, respectively, fulfilling the standard required by the ANSI/AAMI/ISO protocol. All observer differences were within 4 mmHg. CONCLUSION: According to the BHS protocol, the Microlife 3AS1-2 BP device is accurate in pregnant women with low BP. The device has been validated previously in pregnancy and pre-eclampsia and also fulfils the criteria of the WHO for use in a low-resource setting. Although unstable women were not included in this validation (for safety and pragmatic reasons), this device could potentially improve the detection of shock secondary to obstetric haemorrhage or sepsis, as well as being used in pre-eclampsia, particularly in low-income and middle-income countries.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“The device has additionally been validated as accurate for use in women with preeclampsia [12] and in those who develop low BP from sepsis or haemorrhage [13].”
Citations
Cites
Still being checked.
Cited by
Kitt, J., Fox, R., Tucker, K. L., & McManus, R. J. (2019) · Current Hypertension Reports · doi:10.1007/s11906-019-0949-4 · Cited by 177
Bello, N. A., Woolley, J. J., Cleary, K. L., Falzon, L., Alpert, B. S., Oparil, S., Cutter, G., Wapner, R. J., Muntner, P., Tita, A., et al. (2017) · Hypertension · doi:10.1161/hypertensionaha.117.10295 · Cited by 138
El Ayadi, A. M., Nathan, H. L., Seed, P. T., Butrick, E. A., Hezelgrave, N. L., Shennan, A. H., & Miller, S. (2016) · PLOS ONE · doi:10.1371/journal.pone.0148729 · Cited by 121
Self-citationThe assessment of blood pressure in pregnant women: pitfalls and novel approaches
Hurrell, A., Webster, L., Chappell, L. C., & Shennan, A. H. (2021) · American Journal of Obstetrics and Gynecology · doi:10.1016/j.ajog.2020.10.026 · Cited by 81
Self-citationNathan, H. L., Seed, P. T., Hezelgrave, N. L., de Greeff, A., Lawley, E., Anthony, J., Steyn, W., Hall, D. R., Chappell, L. C., & Shennan, A. H. (2019) · Acta Obstetricia Et Gynecologica Scandinavica · doi:10.1111/aogs.13626 · Cited by 75
Self-citation
Metadata
- Authors
- Nathan, H. L., de Greeff, A., Hezelgrave, N. L., Chappell, L. C., & Shennan, A. H.
- Affiliations
- St Thomas' Hospital (GB)
- Corresponding author
- Shennan, Andrew H.
- Venue
- Blood Pressure Monitoring
- Published
- 2015-10
- Volume
- 20
- Issue
- 5
- Pages
- 299-302
- ISSN
- 1359-5237 (ISSN-L)
- OpenAlex
- W2396706466
- Cited by
- 35
- References
- 0
- Citations by year
- 2023: 3 · 2022: 3 · 2021: 4 · 2020: 5 · 2019: 6 · 2018: 7 · 2017: 5 · 2016: 2
- FWCI
- 3.36
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- Blood Pressure Monitoring (publishedVersion)
- PubMed (publishedVersion)
- Research Portal (King's College London) (submittedVersion)
- Funders
- National Institute for Health and Care Research (ACF-2009-17-019, DRF-2013-06-171, RP-2014-05-019)
- Medical Research Council (MR/N006240/1)
- Topics
- Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Blood Pressure and Hypertension Studies
- Health Sciences › Medicine › Obstetrics and Gynecology › Pregnancy and preeclampsia studies
- Physical Sciences › Engineering › Biomedical Engineering › Non-Invasive Vital Sign Monitoring
- Keywords
- pregnancy, hypotension, British Hypertension Society protocol, preeclampsia, obstetric hemorrhage, sepsis, resource-limited settings, South Africa
- MeSH terms
- Anthropometry, Arm, Blood Pressure Determination, Clinical Protocols, Developing Countries, Diastole, Female, Hemodynamics, Humans, Hypotension, Income, Oscillometry, Pregnancy, Pregnancy Complications, Cardiovascular, Prospective Studies, Systole, Observer Variation
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Accuracy validation of the Microlife 3AS1-2 blood pressure device in a pregnant population with low blood pressure. https://app.cochat.ai/papers/10.1097/mbp.0000000000000134
- The paper
- Nathan, H. L., de Greeff, A., Hezelgrave, N. L., Chappell, L. C., & Shennan, A. H. (2015). Accuracy validation of the Microlife 3AS1-2 blood pressure device in a pregnant population with low blood pressure. Blood Pressure Monitoring. https://doi.org/10.1097/mbp.0000000000000134
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.