Accuracy validation of the Microlife 3AS1-2 blood pressure device in a pregnant population with low blood pressure

Nathan, Hannah L., de Greeff, Annemarie, Hezelgrave, Natasha L., Chappell, Lucy C., Shennan, Andrew H. · 2015 · Blood Pressure Monitoring

Abstract

OBJECTIVE: To assess the accuracy of the Microlife 3AS1-2 blood pressure (BP) device in pregnant women with low BP to investigate suitability for hypotensive detection in low-income and middle-income countries. METHODS: A prospective observational study was carried out evaluating the Microlife 3AS1-2, a hand-held, upper-arm, semiautomated BP device, according to British Hypertension Society (BHS) protocol methods. Thirty (stable) pregnant women with a clinical systolic BP less than 100 mmHg and/or diastolic BP less than 60 mmHg were recruited from antenatal wards and clinics and their BP was measured by three trained observers at a district-level hospital in South Africa. Accuracy was assessed according to the BHS grading criteria (A/B=pass) and the ANSI/AAMI/ISO standard for mean difference and SD (≤5±8 mmHg). RESULTS: The device achieved an A/A grade according to the BHS grading criteria. The mean difference±SD between the observer and the test device was 0.5±6.2 and 1.3±5.4 mmHg for systolic and diastolic BP, respectively, fulfilling the standard required by the ANSI/AAMI/ISO protocol. All observer differences were within 4 mmHg. CONCLUSION: According to the BHS protocol, the Microlife 3AS1-2 BP device is accurate in pregnant women with low BP. The device has been validated previously in pregnancy and pre-eclampsia and also fulfils the criteria of the WHO for use in a low-resource setting. Although unstable women were not included in this validation (for safety and pragmatic reasons), this device could potentially improve the detection of shock secondary to obstetric haemorrhage or sepsis, as well as being used in pre-eclampsia, particularly in low-income and middle-income countries.

Overview

Integrity signals

Registry

Crossref · 10.1097/mbp.0000000000000134

Cites

Statistics

Recomputing p-values needs the paper’s full text.

Verification

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Citations

Cites

Still being checked.

Cited by

See all 35

Metadata

Authors
Nathan, H. L., de Greeff, A., Hezelgrave, N. L., Chappell, L. C., & Shennan, A. H.
Affiliations
St Thomas' Hospital (GB)
Corresponding author
Shennan, Andrew H.
Venue
Blood Pressure Monitoring
Published
2015-10
Volume
20
Issue
5
Pages
299-302
ISSN
1359-5237 (ISSN-L)
OpenAlex
W2396706466
Cited by
35
References
0
Citations by year
2023: 3 · 2022: 3 · 2021: 4 · 2020: 5 · 2019: 6 · 2018: 7 · 2017: 5 · 2016: 2
FWCI
3.36
Type
journal article
Language
en
Open access
closed
Locations
  • Blood Pressure Monitoring (publishedVersion)
  • PubMed (publishedVersion)
  • Research Portal (King's College London) (submittedVersion)
Funders
  • National Institute for Health and Care Research (ACF-2009-17-019, DRF-2013-06-171, RP-2014-05-019)
  • Medical Research Council (MR/N006240/1)
Topics
  • Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Blood Pressure and Hypertension Studies
  • Health Sciences › Medicine › Obstetrics and Gynecology › Pregnancy and preeclampsia studies
  • Physical Sciences › Engineering › Biomedical Engineering › Non-Invasive Vital Sign Monitoring
Keywords
pregnancy, hypotension, British Hypertension Society protocol, preeclampsia, obstetric hemorrhage, sepsis, resource-limited settings, South Africa
MeSH terms
Anthropometry, Arm, Blood Pressure Determination, Clinical Protocols, Developing Countries, Diastole, Female, Hemodynamics, Humans, Hypotension, Income, Oscillometry, Pregnancy, Pregnancy Complications, Cardiovascular, Prospective Studies, Systole, Observer Variation

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Accuracy validation of the Microlife 3AS1-2 blood pressure device in a pregnant population with low blood pressure. https://app.cochat.ai/papers/10.1097/mbp.0000000000000134
The paper
Nathan, H. L., de Greeff, A., Hezelgrave, N. L., Chappell, L. C., & Shennan, A. H. (2015). Accuracy validation of the Microlife 3AS1-2 blood pressure device in a pregnant population with low blood pressure. Blood Pressure Monitoring. https://doi.org/10.1097/mbp.0000000000000134

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.