Accuracy validation of the Microlife 3AS1-2 blood pressure device in a pregnant population with low blood pressure
The DOI matches its Crossref record.
Abstract
OBJECTIVE: To assess the accuracy of the Microlife 3AS1-2 blood pressure (BP) device in pregnant women with low BP to investigate suitability for hypotensive detection in low-income and middle-income countries. METHODS: A prospective observational study was carried out evaluating the Microlife 3AS1-2, a hand-held, upper-arm, semiautomated BP device, according to British Hypertension Society (BHS) protocol methods. Thirty (stable) pregnant women with a clinical systolic BP less than 100 mmHg and/or diastolic BP less than 60 mmHg were recruited from antenatal wards and clinics and their BP was measured by three trained observers at a district-level hospital in South Africa. Accuracy was assessed according to the BHS grading criteria (A/B=pass) and the ANSI/AAMI/ISO standard for mean difference and SD (≤5±8 mmHg). RESULTS: The device achieved an A/A grade according to the BHS grading criteria. The mean difference±SD between the observer and the test device was 0.5±6.2 and 1.3±5.4 mmHg for systolic and diastolic BP, respectively, fulfilling the standard required by the ANSI/AAMI/ISO protocol. All observer differences were within 4 mmHg. CONCLUSION: According to the BHS protocol, the Microlife 3AS1-2 BP device is accurate in pregnant women with low BP. The device has been validated previously in pregnancy and pre-eclampsia and also fulfils the criteria of the WHO for use in a low-resource setting. Although unstable women were not included in this validation (for safety and pragmatic reasons), this device could potentially improve the detection of shock secondary to obstetric haemorrhage or sepsis, as well as being used in pre-eclampsia, particularly in low-income and middle-income countries.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“The device has additionally been validated as accurate for use in women with preeclampsia [12] and in those who develop low BP from sepsis or haemorrhage [13].”
Citations
Cited by
Kitt, J., Fox, R., Tucker, K. L., & McManus, R. J. (2019) · Current Hypertension Reports · doi:10.1007/s11906-019-0949-4 · Cited by 181
Bello, N. A., Woolley, J. J., Cleary, K. L., Falzon, L., Alpert, B. S., Oparil, S., Cutter, G., Wapner, R., Muntner, P., Tita, A. T., et al. (2018) · Hypertension · doi:10.1161/hypertensionaha.117.10295 · Cited by 126
El Ayadi, A. M., Nathan, H. L., Seed, P. T., Butrick, E. A., Hezelgrave, N. L., Shennan, A. H., & Miller, S. (2016) · PLOS ONE · doi:10.1371/journal.pone.0148729 · Cited by 121
Self-citationThe assessment of blood pressure in pregnant women: pitfalls and novel approaches
Hurrell, A., Webster, L., Chappell, L. C., & Shennan, A. H. (2021) · American Journal of Obstetrics and Gynecology · doi:10.1016/j.ajog.2020.10.026 · Cited by 81
Self-citationNathan, H. L., Seed, P. T., Hezelgrave, N. L., de Greeff, A., Lawley, E., Anthony, J., Steyn, W., Hall, D. R., Chappell, L. C., & Shennan, A. H. (2019) · Acta Obstetricia Et Gynecologica Scandinavica · doi:10.1111/aogs.13626 · Cited by 76
Self-citationPoint-of-care diagnostics to improve maternal and neonatal health in low-resource settings
Majors, C. E., Smith, C. A., Natoli, M. E., Kundrod, K. A., & Richards-Kortum, R. R. (2017) · Lab on a Chip · doi:10.1039/c7lc00374a · Cited by 57
Vousden, N., Lawley, E., Nathan, H. L., Seed, P. T., Gidiri, M. F., Goudar, S., Sandall, J., Chappell, L. C., Shennan, A. H., Kachinjika, M., et al. (2019) · The Lancet Global Health · doi:10.1016/s2214-109x(18)30526-6 · Cited by 48
Self-citationthe CLIP Working Group, Nathan, H. L., Boene, H., Munguambe, K., Sevene, E., Akeju, D., Adetoro, O. O., Charanthimath, U., Bellad, M. B., de Greeff, A., et al. (2018) · Reproductive Health · doi:10.1186/s12978-017-0450-y · Cited by 41
“The device has been accuracy validated in pregnancy, including pre-eclampsia and hypotensive pregnancies, according to formal validation protocols [3, 4].”
MethodSelf-citationNathan, H. L., Seed, P. T., Hezelgrave, N. L., De Greeff, A., Lawley, E., Anthony, J., Hall, D. R., Steyn, W., Chappell, L. C., & Shennan, A. H. (2018) · Pregnancy Hypertension · doi:10.1016/j.preghy.2017.11.003 · Cited by 40
Self-citationPreeclampsia in 2017: Obstetric and Anaesthesia Management
Hofmeyr, R., Matjila, M. J., & Dyer, R. A. (2016) · Best practice & research. Clinical anaesthesiology · doi:10.1016/j.bpa.2016.12.002 · Cited by 46
Nathan, H. L., Vousden, N., Lawley, E., de Greeff, A., Hezelgrave, N. L., Sloan, N., Tanna, N., Goudar, S. S., Gidiri, M. F., Sandall, J., et al. (2018) · BMJ Innovations · doi:10.1136/bmjinnov-2017-000235 · Cited by 31
Self-citationon behalf of the CRADLE Trial Collaborative Group, Vousden, N., Lawley, E., Seed, P. T., Gidiri, M. F., Charantimath, U., Makonyola, G., Brown, A., Yadeta, L., Best, R., et al. (2019) · Implementation Science · doi:10.1186/s13012-019-0885-3 · Cited by 31
Self-citationthe PRECISE Network, von Dadelszen, P., Flint-O’Kane, M., Lucilla, P., Craik, R., Russell, D., Tribe, R. M., D’Alessandro, U., Roca, A., Jah, H., et al. (2020) · Reproductive Health · doi:10.1186/s12978-020-0872-9 · Cited by 37
Self-citationon behalf of the CRADLE Trial Collaborative Group, Vousden, N., Lawley, E., Nathan, H. L., Seed, P. T., Brown, A., Muchengwa, T., Charantimath, U., Bellad, M., Gidiri, M. F., et al. (2018) · BMC Pregnancy and Childbirth · doi:10.1186/s12884-018-1737-x · Cited by 30
“It has been extensively validated for accuracy [4, 5] and usability [6] and the need defined in this context through field work and stakeholder engagement.”
BackgroundSelf-citationInnovations in vital signs measurement for the detection of hypertension and shock in pregnancy
Vousden, N., Nathan, H. L., & Shennan, A. H. (2018) · Reproductive Health · doi:10.1186/s12978-018-0533-4 · Cited by 29
“as well as in pregnancy, including women with hypertension [45] or hypotension [46].”
BackgroundSelf-citationNathan, H. L., Duhig, K. E., Vousden, N., Lawley, E., Seed, P. T., Sandall, J., Bellad, M. B., Brown, A. C., Chappell, L. C., Goudar, S. S., et al. (2018) · Trials · doi:10.1186/s13063-018-2581-z · Cited by 20
Self-citationGiblin, L., Vousden, N., Nathan, H. L., Gidiri, F., Goudar, S. S., Charantimath, U., Sandall, J., Seed, P. T., Chappell, L. C., & Shennan, A. H. (2021) · BMC Pregnancy and Childbirth · doi:10.1186/s12884-021-03796-4 · Cited by 17
Self-citationEffect of positioning on blood pressure measurement in pregnancy
Myers, M. C., Brandt, D. S., Prunty, A., Gilbertson‐White, S., Sanborn, A. N., Santillan, M. K., & Santillan, D. A. (2022) · Pregnancy Hypertension · doi:10.1016/j.preghy.2021.12.013 · Cited by 15
Seward, N., Hanlon, C., Murdoch, J., Colbourn, T., Prince, M. J., Venkatapuram, S., & Sevdalis, N. (2020) · BMJ Global Health · doi:10.1136/bmjgh-2020-003456 · Cited by 15
Adepoju, A., Vidler, M., Akadri, A. A., Jaiyesimi, E., Nwankpa, C. C., Odubena, O. O., Sharma, S., Li, L., Tu, D. K., Drebit, S. K., et al. (2021) · Pregnancy Hypertension · doi:10.1016/j.preghy.2021.05.005 · Cited by 12
Self-citationAgreement of aneroid and oscillometric blood pressure devices used in pregnancy
Aldridge, E., Mollen, J., Verburg, P. E., Wittwer, M. R., Dekker, G., Roberts, C. T., & Arstall, M. A. (2019) · Pregnancy Hypertension · doi:10.1016/j.preghy.2019.05.005 · Cited by 11
Shobo, O. G., Okoro, A., Okolo, M., Longtoe, P., Omale, I., Ofiemu, E., & Anyanti, J. (2020) · Implementation Science Communications · doi:10.1186/s43058-020-00076-8 · Cited by 14
Ridout, A. E., Moses, F. L., Herm-Singh, S., Turienzo, C. F., Seed, P. T., Goodhart, V., Vousden, N., Sam, B., Momoh, M., Kamara, D., et al. (2023) · Trials · doi:10.1186/s13063-023-07587-4 · Cited by 8
Self-citationReverse innovation in maternal health
Firoz, T., Makanga, P. T., Nathan, H. L., Payne, B. A., & Magee, L. A. (2017) · Obstetric Medicine · doi:10.1177/1753495x17700515 · Cited by 7
Self-citationLihme, F., Madsen, M. E., & Lykke, J. A. (2017) · Blood Pressure Monitoring · doi:10.1097/mbp.0000000000000277 · Cited by 4
Blood pressure measurement in pregnancy
Beardmore‐Gray, A., Dyer, R. A., & Shennan, A. H. (2018) · International Journal of Obstetric Anesthesia · doi:10.1016/j.ijoa.2018.11.006 · Cited by 2
Self-citationKuhrt, K., Seed, P. T., & Shennan, A. H. (2023) · Tropical Doctor · doi:10.1177/00494755221134975 · Cited by 1
Self-citationThe challenge of measuring blood pressure in low-resource settings
Roberts, J. M., & Assibey‐Mensah, V. (2019) · The Lancet Global Health · doi:10.1016/s2214-109x(19)30019-1 · Cited by 1
Eley, V. A., Christensen, R., Kumar, S., & Callaway, L. K. (2018) · International Journal of Obstetric Anesthesia · doi:10.1016/j.ijoa.2018.11.003
Kuhrt, K., Seed, P. T., & Shennan, A. H. (2021) · Research Square · doi:10.21203/rs.3.rs-205157/v1
Self-citationKuhrt, K., Seed, P. T., & Shennan, A. H. (2020) · Research Square · doi:10.21203/rs.3.rs-47471/v1
Self-citationTsioufis, C. (2020) · Faculty Opinions – Post-Publication Peer Review of the Biomedical Literature · doi:10.3410/f.735682942.793578593
Hedetoft, K., Lihme, F., & Lykke, J. A. (2022) · Danish Journal of Obstetrics and Gynaecology · doi:10.56182/djog.v1i1.12
Lihme, F., Hedetoft, K., Persson, L., & Lykke, J. A. (2022) · Danish Journal of Obstetrics and Gynaecology · doi:10.56182/djog.v1i1.24
Metadata
- Authors
- Nathan, H. L., de Greeff, A., Hezelgrave, N. L., Chappell, L. C., & Shennan, A. H.
- Affiliations
- St Thomas' Hospital (GB)
- Corresponding author
- Shennan, Andrew H.
- Venue
- Blood Pressure Monitoring
- Published
- 2015-10
- Volume
- 20
- Issue
- 5
- Pages
- 299-302
- ISSN
- 1359-5237 (ISSN-L)
- OpenAlex
- W2396706466
- Cited by
- 35
- References
- 0
- Citations by year
- 2023: 3 · 2022: 3 · 2021: 4 · 2020: 5 · 2019: 6 · 2018: 7 · 2017: 5 · 2016: 2
- FWCI
- 3.36
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- Blood Pressure Monitoring (publishedVersion)
- PubMed (publishedVersion)
- Research Portal (King's College London) (submittedVersion)
- Funders
- National Institute for Health and Care Research (ACF-2009-17-019, DRF-2013-06-171, RP-2014-05-019)
- Medical Research Council (MR/N006240/1)
- Topics
- Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Blood Pressure and Hypertension Studies
- Health Sciences › Medicine › Obstetrics and Gynecology › Pregnancy and preeclampsia studies
- Physical Sciences › Engineering › Biomedical Engineering › Non-Invasive Vital Sign Monitoring
- Keywords
- pregnancy, hypotension, British Hypertension Society protocol, preeclampsia, obstetric hemorrhage, sepsis, resource-limited settings, South Africa
- MeSH terms
- Anthropometry, Arm, Blood Pressure Determination, Clinical Protocols, Developing Countries, Diastole, Female, Hemodynamics, Humans, Hypotension, Income, Oscillometry, Pregnancy, Pregnancy Complications, Cardiovascular, Prospective Studies, Systole, Observer Variation
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.