Validation of an oscillometric home blood pressure monitor in an end-stage renal disease population and the effect of arterial stiffness on its accuracy
The DOI matches its Crossref record; 8 of the 8 references it cites were found in a registry or an index.
Abstract
OBJECTIVES: Increased arterial stiffness, common in end-stage renal disease patients, has been shown to affect the correspondence between oscillometric and mercury sphygmomanometer blood pressure readings. The purpose of this study was to validate an oscillometric home blood pressure monitor in an end-stage renal disease population and to determine the effect of arterial stiffness on its accuracy. METHODS: Blood pressure measurements were taken with the Microlife 3AC1-1PC (Microlife; Taipei, Taiwan), an oscillometric home blood pressure monitor, and a mercury sphygmomanometer in 33 patients as specified by the European Society of Hypertension Validation Protocol. Radial pulse wave analyses were also performed. RESULTS: On the basis of European Society of Hypertension criteria, the Microlife 3AC1-1PC received a passing score for systolic and diastolic blood pressures. On average, the oscillometric monitor overestimated diastolic blood pressure by 2.4 mmHg (P=0.005, SD=4.5 mmHg) and there was a trend towards overestimation of systolic blood pressure as well (1.3 mmHg, P=0.09, SD=4.4 mmHg). A positive correlation was found between arterial stiffness, as assessed by augmentation index and pulse pressure, and the diastolic blood pressure difference between the device and the mercury sphygmomanometer (r=0.54, P=0.003; and r=0.65, P=0.001, respectively). Diastolic blood pressure was negatively correlated with the diastolic blood pressure difference (r=-0.49, P=0.003). No significant relationship was found between the systolic blood pressure difference and augmentation index, pulse pressure or systolic blood pressure. CONCLUSION: The Microlife 3AC1-1PC was shown to accurately measure blood pressure in patients with end-stage renal disease. As arterial stiffness increased and diastolic blood pressure fell, diastolic blood pressure was increasingly overestimated.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Pickering, T. G., Hall, J. E., Appel, L. J., Falkner, B. E., Graves, J., Hill, M. N., Jones, D. W., Kurtz, T., Sheps, S. G., & Roccella, E. J. (2005) · Hypertension · doi:10.1161/01.hyp.0000150859.47929.8e · Cited by 2,051
Self-citationO'Brien, E., Asmar, R., Beilin, L., Imai, Y., Mallion, J.-M., Mancia, G., Mengden, T., Myers, M., Padfield, P., Palatini, P., et al. (2003) · Journal of Hypertension · doi:10.1097/00004872-200305000-00001 · Cited by 1,655
Self-citationPauca, A. L., O’Rourke, M. F., & Kon, N. D. (2001) · Hypertension · doi:10.1161/hy1001.096106 · Cited by 1,179
Bobrie, G. (2004) · JAMA · doi:10.1001/jama.291.11.1342 · Cited by 842
Agarwal, R., Peixoto, A. J., Santos, S. F. F., & Zoccali, C. (2006) · Clinical Journal of the American Society of Nephrology · doi:10.2215/cjn.01891105 · Cited by 245
Home blood pressure monitoring improves the diagnosis of hypertension in hemodialysis patients
Agarwal, R., Andersen, M. J., Bishu, K., & Saha, C. (2006) · Kidney International · doi:10.1038/sj.ki.5000145 · Cited by 175
van Popele, N. M., Bos, W. J. W., de Beer, N. A. M., van der Kuip, D. A. M., Hofman, A., Grobbee, D. E., & Witteman, J. C. M. (2000) · Hypertension · doi:10.1161/01.hyp.36.4.484 · Cited by 170
van Ittersum, F. J., Wijering, R. M. J., Lambert, J., Donker, A. J. M., & Stehouwer, C. D. A. (1998) · Journal of Hypertension · doi:10.1097/00004872-199816080-00007 · Cited by 52
Cited by
European Society of hypertension position paper on ambulatory blood pressure monitoring
O’Brien, E., Parati, G., Stergiou, G., Asmar, R., Beilin, L., Bilo, G., Clement, D., de la Sierra, A., de Leeuw, P., Dolan, E., et al. (2013) · Journal of Hypertension · doi:10.1097/hjh.0b013e328363e964 · Cited by 1,419
Parati, G., Stergiou, G. S., Asmar, R., Bilo, G., de Leeuw, P., Imai, Y., Kario, K., Lurbe, E., Manolis, A., Mengden, T., et al. (2008) · Journal of Hypertension · doi:10.1097/hjh.0b013e328308da66 · Cited by 837
Self-citationPickering, T. G., Miller, N. H., Ogedegbe, G., Krakoff, L. R., Artinian, N. T., & Goff, D. (2008) · Hypertension · doi:10.1161/hypertensionaha.107.189010 · Cited by 668
Self-citationOscillometric Blood Pressure Estimation: Past, Present, and Future
Forouzanfar, M., Dajani, H. R., Groza, V. Z., Bolic, M., Rajan, S., & Batkin, I. (2015) · IEEE Reviews in Biomedical Engineering · doi:10.1109/rbme.2015.2434215 · Cited by 196
Stergiou, G. S., Lourida, P., Tzamouranis, D., & Baibas, N. M. (2009) · Journal of Human Hypertension · doi:10.1038/jhh.2009.20 · Cited by 74
Metadata
- Authors
- Thompson, A. M., Eguchi, K., Reznik, M. E., Shah, S. S., & Pickering, T. G.
- Venue
- Blood Pressure Monitoring
- Published
- 2007-08
- Volume
- 12
- Issue
- 4
- Pages
- 227-232
- ISSN
- 1359-5237 (ISSN-L)
- OpenAlex
- W2064184581
- Cited by
- 48
- References
- 8
- FWCI
- 2.38
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Validation of an oscillometric home blood pressure monitor in an end-stage renal disease population and the effect of arterial stiffness on its accuracy. https://app.cochat.ai/papers/10.1097/mbp.0b013e328108f544
- The paper
- Thompson, A. M., Eguchi, K., Reznik, M. E., Shah, S. S., & Pickering, T. G. (2007). Validation of an oscillometric home blood pressure monitor in an end-stage renal disease population and the effect of arterial stiffness on its accuracy. Blood Pressure Monitoring. https://doi.org/10.1097/mbp.0b013e328108f544
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.