Validation of the A&D UM-101 professional hybrid device for office blood pressure measurement according to the International Protocol
The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Abstract
OBJECTIVE: Assessment of the accuracy of the A&D UM-101 mercury-free professional device for auscultatory blood pressure (BP) measurement according to the European Society of Hypertension International Protocol. Further to auscultation, the device has a button to mark readings during deflation. METHODS: Fifteen adults were included in phase 1 and another 18 in phase 2. Simultaneous BP measurements were taken by two observers (connected mercury sphygmomanometers) four times, sequentially with three measurements using the tested device (two connected tested devices, one used with and the other without the mark button). RESULTS: In phase 1, the device produced 44/45/45 measurements within 5/10/15 mmHg, respectively, for systolic BP (SBP) and 39/43/45 for diastolic (DBP). In phase 2.1, 87/97/99 measurements within 5/10/15 mmHg, respectively, for SBP, and 91/97/99 for DBP (using the mark button 65/93/98 for SBP and 76/96/99 for DBP). In phase 2.2, 29 participants had at least two of their SBP differences within 5 mmHg and none had any differences within 5 mmHg, whereas 32 and none, respectively, for DBP (with mark 24/4 participants for SBP; 29/1 for DBP). Mean SBP differences were -1.5+/-3.5 mmHg and DBP -1.3+/-3.0 (with mark -3.6+/-4.2 and -2.8+/-3.7). The difference in SBP measured by the tested device with versus without using the mark button was 3.0+/-3.3 mmHg (P<0.001) and DBP 1.9+/-2.5 mmHg (P<0.001). CONCLUSION: The device comfortably passed the validation protocol requirements. Using the mark button, the device, however, failed to meet the validation criteria. Therefore, it is recommended for clinical use without using the mark button.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Pickering, T. G., Hall, J. E., Appel, L. J., Falkner, B. E., Graves, J., Hill, M. N., Jones, D. W., Kurtz, T., Sheps, S. G., & Roccella, E. J. (2005) · Hypertension · doi:10.1161/01.hyp.0000150859.47929.8e · Cited by 2,051
O'Brien, E., Asmar, R., Beilin, L., Imai, Y., Mallion, J.-M., Mancia, G., Mengden, T., Myers, M., Padfield, P., Palatini, P., et al. (2003) · Journal of Hypertension · doi:10.1097/00004872-200305000-00001 · Cited by 1,655
Self-citationAge differences and changes in reaction time: the Baltimore Longitudinal Study of Aging.
Fozard, J. L., Vercruyssen, M., Reynolds, S. L., Hancock, P. A., & Quilter, R. E. (1994) · Journal of Gerontology · doi:10.1093/geronj/49.4.p179 · Cited by 408
Cited by
SOMANZ guidelines for the management of hypertensive disorders of pregnancy 2014
Lowe, S. A., Bowyer, L., Lust, K., McMahon, L. P., Morton, M., North, R. A., Paech, M., & Said, J. M. (2015) · Australian and New Zealand Journal of Obstetrics and Gynaecology · doi:10.1111/ajo.12399 · Cited by 299
Exercise blood pressure: Clinical relevance and correct measurement
Sharman, J. E., & LaGerche, A. (2015) · Journal of Human Hypertension · doi:10.1038/jhh.2014.84 · Cited by 142
Stergiou, G. S., Lourida, P., & Tzamouranis, D. (2011) · Journal of Human Hypertension · doi:10.1038/jhh.2010.107 · Cited by 18
Self-citationMoore, M. N., Picone, D. S., Callisaya, M. L., Srikanth, V., Sharman, J. E., & Schultz, M. G. (2019) · The Journal of Clinical Hypertension · doi:10.1111/jch.13717 · Cited by 9
Metadata
- Authors
- Stergiou, G. S., Giovas, P. P., Gkinos, C. P., & Tzamouranis, D. G.
- Venue
- Blood Pressure Monitoring
- Published
- 2008-02
- Volume
- 13
- Issue
- 1
- Pages
- 37-42
- ISSN
- 1359-5237 (ISSN-L)
- OpenAlex
- W2119820765
- Cited by
- 32
- References
- 3
- FWCI
- 1.54
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.