CoChat

Prognostic significance of ambulatory blood pressure in hypertensive patients with history of cardiovascular disease

Open access
Fagard, Robert H., Thijs, Lutgarde, Staessen, Jan A., Clement, Denis L., De Buyzere, Marc L., De Bacquer, Dirk A. · 2008 · Blood Pressure Monitoring
Cited by 66

The DOI matches its Crossref record; 11 of the 11 references it cites were found in a registry or an index.

Abstract

OBJECTIVE: To assess the prognostic significance of nighttime and daytime blood pressure (BP), their ratio and the nighttime dipping pattern for mortality and recurrent cardiovascular (CV) events in patients with CV disease at baseline. BACKGROUND: The prognostic value of ambulatory BP has not been reported in hypertensive patients with a history of CV disease. METHODS: We performed a meta-analysis on individual data of 302 patients with hypertension and CV disease from three prospective studies performed in Europe. RESULTS: Age of the patients averaged 69+/-9 years; 50% were men and 62% were under antihypertensive treatment at the time of ambulatory BP monitoring. Office, daytime and nighttime BP averaged 161+/-20/86+/-12, 144+/-16/83+/-11 and 132+/-18/72+/-12 mmHg. Total follow-up time amounted to 2049 patient--years. Multivariable Cox regression analysis revealed that nighttime BP, but not daytime BP significantly predicted CV mortality (P< or =0.05) and major CV events (P< or =0.01) after adjustment for office BP and other confounders. When both nighttime and daytime BP were entered into the models, the predictive power of nighttime BP remained significant (P< or =0.05); daytime BP did not add prognostic precision to nighttime BP. The systolic nightday BP ratio predicted all outcomes, and outcome was significantly worse in reverse dippers and nondippers than in dippers, both before and after adjustment for 24-h BP (P< or =0.05). CONCLUSION: Nighttime BP is the better predictor of death and recurrent CV events in hypertensive patients with a history of CV disease. The night-day BP ratio and the dipping pattern significantly predict outcome, even after adjustment for 24-h BP.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1097/mbp.0b013e32831054f5

Cites

11 of 11 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 66

Metadata

Authors
Fagard, R. H., Thijs, L., Staessen, J. A., Clement, D. L., De Buyzere, M. L., & De Bacquer, D. A.
Venue
Blood Pressure Monitoring
Published
2008-12
Volume
13
Issue
6
Pages
325-332
ISSN
1359-5237 (ISSN-L)
OpenAlex
W2095670879
Cited by
66
References
11
FWCI
2.86
Type
journal article
Language
en
Open access
green

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.