Home sphygmomanometers: validation versus accuracy
The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Abstract
OBJECTIVE: The validation and accuracy of sphygmomanometers are important issues in the home sphygmomanometer market and in clinical practice. The aims of this study are to assess the frequency of validated home sphygmomanometers and to evaluate the relationship between the validation and accuracy of the devices. METHODS: Eight hundred and ninety-six home sphygmomanometers were brought by individuals to the University Hospital Hypertension Clinic for this study, and 870 (97%) of the devices were in adequate working condition and suitable for analysis. The relationship between accuracy and validation was investigated only in automated sphygmomanometers (n = 554). RESULTS: Both the manufacturer and model were known in 500 devices (90%), and these devices were eligible for evaluation of validation. We found 74 devices listed in the dabl Educational Trust website. Twenty-two of the 74 (30%) devices were validated. Four hundred (72%) of the 554 automated sphygmomanometers were inaccurate. The frequency of accuracy was higher among validated devices compared with nonvalidated devices (68 vs. 15%) (P<0.01). CONCLUSION: Our study showed that the frequency of accurate devices was higher among validated sphygmomanometers compared with nonvalidated sphygmomanometers. To our knowledge, our study is the first to demonstrate the relationship between accuracy and validation of home sphygmomanometers. The frequency of device-related errors can be decreased by training patients and supervising the blood pressure device market. Nonprofit organizations can help patients to overcome some of the problems in the blood pressure device market.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Pickering, T. G., Hall, J. E., Appel, L. J., Falkner, B. E., Graves, J., Hill, M. N., Jones, D. W., Kurtz, T., Sheps, S. G., & Roccella, E. J. (2005) · Hypertension · doi:10.1161/01.hyp.0000150859.47929.8e · Cited by 2,051
O'Brien, E., Asmar, R., Beilin, L., Imai, Y., Mallion, J.-M., Mancia, G., Mengden, T., Myers, M., Padfield, P., Palatini, P., et al. (2003) · Journal of Hypertension · doi:10.1097/00004872-200305000-00001 · Cited by 1,655
Accuracy of the pressure scale of sphygmomanometers in clinical use within primary care
Coleman, A. J., Steel, S. D., Ashworth, M., Vowler, S. L., & Shennan, A. (2005) · Blood Pressure Monitoring · doi:10.1097/01.mbp.0000168398.87167.c2 · Cited by 64
Cited by
Sharman, J. E., O’Brien, E., Alpert, B., Schutte, A. E., Delles, C., Hecht Olsen, M., Asmar, R., Atkins, N., Barbosa, E., Calhoun, D., et al. (2020) · Journal of Hypertension · doi:10.1097/hjh.0000000000002246 · Cited by 139
Picone, D. S., Deshpande, R. A., Schultz, M. G., Fonseca, R., Campbell, N. R. C., Delles, C., Hecht Olsen, M., Schutte, A. E., Stergiou, G., Padwal, R., et al. (2020) · Hypertension · doi:10.1161/hypertensionaha.120.14719 · Cited by 118
How to check whether a blood pressure monitor has been properly validated for accuracy
Picone, D. S., Padwal, R., Campbell, N. R. C., Boutouyrie, P., Brady, T. M., Olsen, M. H., Delles, C., Lombardi, C., Mahmud, A., Meng, Y., et al. (2020) · The Journal of Clinical Hypertension · doi:10.1111/jch.14065 · Cited by 52
Hodgkinson, J. A., Lee, M.-M., Milner, S., Bradburn, P., Stevens, R., Hobbs, F. R., Koshiaris, C., Grant, S., Mant, J., & McManus, R. J. (2020) · British Journal of General Practice · doi:10.3399/bjgp20x710381 · Cited by 52
“22 Conversely, an earlier Canadian study 23 found no difference in monitor performance dependent on validation status but, again, included very few monitors (n = 26) that had been validated.”
Sharman, J. E., Ordunez, P., Brady, T., Parati, G., Stergiou, G., Whelton, P. K., Padwal, R., Olsen, M. H., Delles, C., Schutte, A. E., et al. (2022) · Journal of Human Hypertension · doi:10.1038/s41371-022-00747-0 · Cited by 31
Metadata
- Authors
- Akpolat, T., Dilek, M., Aydogdu, T., Adibelli, Z., Erdem, D. G., & Erdem, E.
- Venue
- Blood Pressure Monitoring
- Published
- 2009-02
- Volume
- 14
- Issue
- 1
- Pages
- 26-31
- ISSN
- 1359-5237 (ISSN-L)
- OpenAlex
- W2081145927
- Cited by
- 46
- References
- 3
- FWCI
- 0.79
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Home sphygmomanometers: validation versus accuracy. https://app.cochat.ai/papers/10.1097/mbp.0b013e3283262f31
- The paper
- Akpolat, T., Dilek, M., Aydogdu, T., Adibelli, Z., Erdem, D. G., & Erdem, E. (2009). Home sphygmomanometers: validation versus accuracy. Blood Pressure Monitoring. https://doi.org/10.1097/mbp.0b013e3283262f31
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.