Oscillometric estimation of central blood pressure: validation of the Mobil-O-Graph in comparison with the SphygmoCor device
The DOI matches its Crossref record; 12 of the 12 references it cites were found in a registry or an index.
Abstract
BACKGROUND: Hypertension is a major risk factor for a wide range of cardiovascular diseases and is typically identified by measuring blood pressure (BP) at the brachial artery. Although such a measurement may accurately determine diastolic BP, systolic BP is not reflected accurately. Current noninvasive techniques for assessing central aortic BP require additional recording of an arterial pressure wave using a high-fidelity applanation tonometer. Within one measurement cycle, the Mobil-O-Graph BP device uses brachial oscillometric BP waves for a noninvasive estimation of central BP. We therefore validated the Mobil-O-Graph against the SphygmoCor device, which is widely known as the commonly used approach for a noninvasive estimation of central BP. METHODS: For each individual, we compared three readings of the central BP values obtained by the Mobil-O-Graph and SphygmoCor device consecutively. One hundred individuals (mean age 56.1 ± 15.4 years) were recruited for measurement.Differences between the central BP values of the test device and the SphygmoCor device were calculated for each measurement. RESULTS: The mean difference (95% confidence interval) for the estimated central systolic BP between both devices was -0.6 ± 3.7 mmHg. Comparison of the central BP values measured by the two devices showed a statistically significant linear correlation (R=0.91, P<0.0001). The mean between-method difference was 0.50 mmHg for central systolic BP estimation. The intrarater reproducibility between both the devices was also comparable. Bland and Altman analyses showed that the mean differences (95% confidence interval) between repeated measurements were 1.89 (0.42-3.36) mmHg and 1.36 (-0.16 to 2.83) mmHg for the SphygmoCor and the Mobil-O-Graph device, respectively. Thus, neither of these differences was statistically significantly different from 0. The limits of agreement were -16.34 to 19.73 and -15.23 to 17.17 mmHg for the SphygmoCor and the Mobil-O-Graph device, respectively. CONCLUSION: Oscillometric noninvasive estimation of central BP with the Mobil-O-Graph BP device is as effective as using the well-established SphygmoCor applanation tonometry device. In comparison, the Mobil-O-Graph combines the widespread benefits of brachial BP measurement and also provides central BP within one measurement.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT
Martin Bland, J., & Altman, D. (1986) · The Lancet · doi:10.1016/s0140-6736(86)90837-8 · Cited by 47,965
(2013) · European Heart Journal · doi:10.1093/eurheartj/eht151 · Cited by 13,655
The CAFE Investigators, CAFE Steering Committee and Writing Committee, Williams, B., Lacy, P. S., Thom, S. M., Cruickshank, K., Stanton, A., Collier, D., Hughes, A. D., Thurston, H., et al. (2006) · Circulation · doi:10.1161/circulationaha.105.595496 · Cited by 1,645
Vlachopoulos, C., Aznaouridis, K., O'Rourke, M. F., Safar, M. E., Baou, K., & Stefanadis, C. (2010) · European Heart Journal · doi:10.1093/eurheartj/ehq024 · Cited by 1,363
Roman, M. J., Devereux, R. B., Kizer, J. R., Lee, E. T., Galloway, J. M., Ali, T., Umans, J. G., & Howard, B. V. (2007) · Hypertension · doi:10.1161/hypertensionaha.107.089078 · Cited by 1,080
Central Blood Pressure Measurements and Antihypertensive Therapy: A Consensus Document
Agabiti-Rosei, E., Mancia, G., O’Rourke, M. F., Roman, M. J., Safar, M. E., Smulyan, H., Wang, J.-G., Wilkinson, I. B., Williams, B., & Vlachopoulos, C. (2007) · Hypertension · doi:10.1161/hypertensionaha.107.090068 · Cited by 620
Validation of a Brachial Cuff-Based Method for Estimating Central Systolic Blood Pressure
Weber, T., Wassertheurer, S., Rammer, M., Maurer, E., Hametner, B., Mayer, C. C., Kropf, J., & Eber, B. (2011) · Hypertension · doi:10.1161/hypertensionaha.111.176313 · Cited by 461
White, W. B., Berson, A. S., Robbins, C., Jamieson, M. J., Prisant, L. M., Roccella, E., & Sheps, S. G. (1993) · Hypertension · doi:10.1161/01.hyp.21.4.504 · Cited by 385
A new oscillometric method for pulse wave analysis: comparison with a common tonometric method
Wassertheurer, S., Kropf, J., Weber, T., van der Giet, M., Baulmann, J., Ammer, M., Hametner, B., Mayer, C. C., Eber, B., & Magometschnigg, D. (2010) · Journal of Human Hypertension · doi:10.1038/jhh.2010.27 · Cited by 363
Self-citationDart, A. M., Gatzka, C. D., Kingwell, B. A., Willson, K., Cameron, J. D., Liang, Y.-L., Berry, K. L., Wing, L. M. H., Reid, C. M., Ryan, P., et al. (2006) · Hypertension · doi:10.1161/01.hyp.0000209340.33592.50 · Cited by 176
Cited by
Elmenhorst, J., Hulpke-Wette, M., Barta, C., Dalla Pozza, R., Springer, S., & Oberhoffer, R. (2015) · Atherosclerosis · doi:10.1016/j.atherosclerosis.2014.11.005 · Cited by 160
Ishøy, P. L., Knop, F. K., Broberg, B. V., Bak, N., Andersen, U. B., Jørgensen, N. R., Holst, J. J., Glenthøj, B. Y., & Ebdrup, B. H. (2017) · Diabetes, Obesity and Metabolism · doi:10.1111/dom.12795 · Cited by 102
Kemmner, S., Lorenz, G., Wobst, J., Kessler, T., Wen, M., Günthner, R., Stock, K., Heemann, U., Burkhardt, K., Baumann, M., et al. (2017) · Nitric Oxide · doi:10.1016/j.niox.2017.01.011 · Cited by 74
McGaughey, T. J., Fletcher, E. A., & Shah, S. A. (2016) · American Journal of Hypertension · doi:10.1093/ajh/hpv134 · Cited by 40
Ebdrup, B. H., Broberg, B. V., Ishøy, P. L., Bak, N., Andersen, U. B., Jørgensen, N. R., Holst, J. J., Knop, F. K., & Glenthøj, B. Y. (2018) · Diabetes, Obesity and Metabolism · doi:10.1111/dom.13204 · Cited by 35
Ambulatory blood pressure and arterial stiffness in individuals with type 1 diabetes
on behalf of the FinnDiane Study Group, Lithovius, R., Gordin, D., Forsblom, C., Saraheimo, M., Harjutsalo, V., & Groop, P.-H. (2018) · Diabetologia · doi:10.1007/s00125-018-4648-5 · Cited by 30
Metadata
- Authors
- Weiss, W., Gohlisch, C., Harsch-Gladisch, C., Tölle, M., Zidek, W., & van der Giet, M.
- Venue
- Blood Pressure Monitoring
- Published
- 2012-06
- Volume
- 17
- Issue
- 3
- Pages
- 128-131
- ISSN
- 1359-5237 (ISSN-L)
- OpenAlex
- W2331662939
- Cited by
- 208
- References
- 12
- FWCI
- 4.80
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.