The DOI matches its Crossref record.
Coupling microcirculation to systemic hemodynamics
Abstract
PURPOSE OF REVIEW: To discuss the role of microcirculatory abnormalities in critically ill patients and the link between systemic hemodynamics and microvascular perfusion. RECENT FINDINGS: Microcirculatory alterations have been repeatedly observed in patients with severe sepsis, but recent findings show that these also occur in patients with severe heart failure and in those submitted to high-risk surgery. More severe and more persistent alterations are observed in patients with a poor outcome. Even though a minimal cardiac output and arterial pressure is mandatory to sustain the microcirculation, this level is not yet well defined and seems to be submitted to high individual variability. Above this level, microcirculation and systemic circulation are relatively dissociated, so that microcirculatory alterations can be observed even when systemic hemodynamics are within satisfactory goals. In addition, the response of the microcirculation to therapeutic interventions is often dissociated from systemic effects. However, microcirculatory perfusion can be affected by cardiac output and arterial pressure when these are critically altered. SUMMARY: Microvascular alterations frequently occur in critically ill patients and these may be implicated in the development of organ failure and are associated with outcome. The link between systemic hemodynamics and microcirculation is relatively loose.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Sepsis: pathophysiology and clinical management
Gotts, J. E., & Matthay, M. A. (2016) · BMJ · doi:10.1136/bmj.i1585 · Cited by 1,243
Chioncel, O., Parissis, J., Mebazaa, A., Thiele, H., Desch, S., Bauersachs, J., Harjola, V.-P., Antohi, E.-L., Arrigo, M., Ben Gal, T., et al. (2020) · European Journal of Heart Failure · doi:10.1002/ejhf.1922 · Cited by 493
Self-citationMicrocirculatory changes in children undergoing cardiac surgery: A prospective observational study
Scolletta, S., Marianello, D., Isgrò, G., Dapoto, A., Terranova, V., Franchi, F., Baryshnikova, E., Carlucci, C., & Ranucci, M. (2016) · British Journal of Anaesthesia · doi:10.1093/bja/aew187 · Cited by 17
Vihonen, H., Kuisma, M., & Nurmi, J. (2018) · Scandinavian Journal of Trauma, Resuscitation and Emergency Medicine · doi:10.1186/s13049-018-0480-7 · Cited by 11
Metadata
- Authors
- De Backer, D., Ortiz, J. A., & Salgado, D.
- Venue
- Current Opinion in Critical Care
- Published
- 2010-06
- Volume
- 16
- Issue
- 3
- Pages
- 250-254
- ISSN
- 1070-5295 (ISSN-L)
- OpenAlex
- W2060675005
- Cited by
- 199
- References
- 0
- FWCI
- 9.64
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Coupling microcirculation to systemic hemodynamics. https://app.cochat.ai/papers/10.1097/mcc.0b013e3283383621
- The paper
- De Backer, D., Ortiz, J. A., & Salgado, D. (2010). Coupling microcirculation to systemic hemodynamics. Current Opinion in Critical Care. https://doi.org/10.1097/mcc.0b013e3283383621
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.