Cited by 17Hemodynamic Monitoring and TherapyCardiac and Coronary Surgery TechniquesCongenital Heart Disease Studies

Microcirculatory changes in children undergoing cardiac surgery: A prospective observational study

Open access
Scolletta, S., Marianello, D., Isgrò, G., Dapoto, A., Terranova, V., Franchi, F., Baryshnikova, E., Carlucci, C. +1 more·2016·British Journal of Anaesthesia

Abstract

Background The effects of cardiac surgery on the microcirculation of children are unknown. The aim of this study was to assess the microcirculatory changes in children undergoing surgery for correction of congenital heart disease.Methods We used a videomicroscope (Sidestream Dark Field, SDF) in a convenience sample of 24 children <five yr old. Total vascular density (TVD, vessels mm(-2)), microvascular flow index (MFI, arbitrary units), proportion of perfused small vessels (PPV, percentage), and perfused vessel density (PVD) were obtained after induction of anaesthesia (T1), at the end of the surgical procedure (T2), after intensive care unit (ICU) admission (T3), and at six h (T4) and 12h (T5) after ICU admission.Results Microcirculatory variables did not significantly change over time. Haemodynamic parameters and microcirculatory variables were not correlated. In a subanalysis conducted for cyanotic (n=7) and acyanotic (n=17) children, repeated measures ANOVA showed a significant interaction between time and the presence of cyanosis for PPV (P=0.03), TVD (P=0.03), and PVD (P=0.03). Weak inverse correlations were found between storage time of transfused red blood cell (RBCs) and MFI at T3 (r=-0.63, P=0.01) and T4 (r=-0.53, P=0.03).Conclusions Microcirculatory variables have a different time-related trend in cyanotic and acyanotic children undergoing cardiac surgery. The storage time of transfused RBCs seems to negatively impact the microcirculation. Further and larger studies are warranted to prove the potential implications of this study.

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1093/bja/aew187

Cites

38 of 38 references verified0 citation errors · 0 not checkable

Statistics

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

  • Infants with cyanotic congenital heart disease showed significant reductions in total vessel density and proportion of perfused vessels.

    “Scolletta et al. evaluated sublingual microcirculation in infants with cyanotic and acyanotic CHD using SDF, noting that while acyanotic infants maintained stable microvascular parameters, those with cyanotic CHD showed significant reductions in total vessel density (TVD) and proportion of perfused vessels (PPV) [86].”

    From Trends and Challenges in Noninvasive Hemodynamic Monitoring of Neonates Following Cardiac Surgery: A Narrative Review (2025) · cites this paper as [86]

    The Table 2 results report a significant increase in PPV over time in cyanotic children and an increase, not a reduction, in TVD. The paper does describe comparatively stable PPV in acyanotic children, but its findings run contrary to the claimed reductions in the cyanotic group. (LLM, conf=0.90)

    Checked by a reasoning model — may be wrong.

    Experimental — accuracy not yet measured
  • In infants with cyanotic and acyanotic congenital heart disease, acyanotic infants maintained stable sublingual microvascular parameters.

    “Scolletta et al. evaluated sublingual microcirculation in infants with cyanotic and acyanotic CHD using SDF, noting that while acyanotic infants maintained stable microvascular parameters, those with cyanotic CHD showed significant reductions in total vessel density (TVD) and proportion of perfused vessels (PPV) [86].”

    From Trends and Challenges in Noninvasive Hemodynamic Monitoring of Neonates Following Cardiac Surgery: A Narrative Review (2025) · cites this paper as [86]

    The subgroup results (Table 2) describe relatively stable PPV and PVD in acyanotic children, but report that their TVD decreased over time, so not all microvascular parameters remained stable. The study included children under five years old, not exclusively infants. The full citing sentence also reverses the reported cyanotic trend: TVD and PPV increased rather than decreased. (LLM, conf=0.87)

    Experimental — accuracy not yet measured

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Cites

Flagged first, then by citations

Cited by

Sorted by citations

Authors
Scolletta, S., Marianello, D., Isgrò, G., Dapoto, A., Terranova, V., Franchi, F., Baryshnikova, E., Carlucci, C., & Ranucci, M.
Affiliations
  • Azienda Ospedaliera Universitaria Senese (IT)
  • University of Siena (IT)
  • IRCCS Policlinico San Donato (IT)
Corresponding author
Scolletta, S.
Venue
British Journal of Anaesthesia
Publisher
Elsevier BV
Published
2016-08
Volume
117
Issue
2
Pages
206-213
ISSN
0007-0912 (ISSN-L)
OpenAlex
W2500307637
Cited by
17
References
38
Citations by year
2026: 1 · 2025: 1 · 2023: 3 · 2022: 2 · 2021: 2 · 2020: 3 · 2019: 3 · 2018: 1 · 2017: 1
FWCI
1.85
Type
journal article
Language
en
Open access
Locations
  • British Journal of Anaesthesia (publishedVersion)
  • PubMed (publishedVersion)
  • HighWire Press Open Archive (submittedVersion)
  • Use Siena air (University of Siena) (submittedVersion)
Topics
  • Health Sciences › Medicine › Surgery › Hemodynamic Monitoring and Therapy
  • Health Sciences › Medicine › Surgery › Cardiac and Coronary Surgery Techniques
  • Health Sciences › Medicine › Epidemiology › Congenital Heart Disease Studies
Keywords
microcirculation, pediatric cardiac surgery, congenital heart disease, sidestream dark field imaging, microvascular flow index, perfused vessel density, cyanotic congenital heart disease, acyanotic congenital heart disease, postoperative intensive care
MeSH terms
Blood Flow Velocity, Child, Preschool, Female, Heart Defects, Congenital, Cardiac Surgical Procedures, Hemodynamics, Humans, Infant, Italy, Male, Microcirculation, Prospective Studies, Sensitivity and Specificity, Microscopy, Video

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review