CoChat

Comparison of Commercially Available Serologic Kits for the Detection of Celiac Disease

Naiyer, Afzal J., Hernandez, Lincoln, Ciaccio, Edward J., Papadakis, Konstantinos, Manavalan, John S., Bhagat, Govind, Green, Peter H. R. · 2009 · Journal of Clinical Gastroenterology
Cited by 80

The DOI matches its Crossref record.

Abstract

BACKGROUND: The sensitivity and specificity of current antihuman tissue transglutaminase (tTG) IgA assays used to detect celiac disease reportedly approach 100%. In addition, the sensitivity of new generation deamidated gliadin peptide (alpha-DGP) antibody assays has also been reported to be similar to the tTG IgA assays. In routine clinical practice, however, the sensitivities and specificities of these tests for diagnosing celiac disease seem to be lower. AIM: We analyzed sensitivities and specificities of 4 IgA tTG and 3 deamidated gliadin peptide (alpha-DGP) kits. METHODS: The performance of 4 tTG IgA assays, A: Inova (Hu red blood cell), B: Binding site (rHu Ag), C: Eurospital (rHu Ag), D: Immco (rHu Ag) and 3 Inova alpha-DGP assays, E: alpha-DGP-IgA, F: alpha-DGP-IgG, and G: alpha-DGP-IgA+G was evaluated using sera from different subsets of celiac disease patients and controls; group 1: active celiac disease n=28, group 2: gluten-free diet n=54, group 3: healthy controls n=40, group 4: disease controls n=57(Crohn's disease n=17, chronic hepatitis n=40). RESULTS: Using the manufacturer's cut-off values, the sensitivities and specificities of different kits ranged from 71.4% to 96.4% and 87.5% to 100%, respectively. When group 1 was compared with disease controls, sensitivities remained the same but specificities decreased. Receiver operating characteristic plot derived cut-off values modified decision thresholds in all assays except kit (G). Kappa analysis demonstrated variable degrees of agreement. All assays demonstrated higher sensitivities for patients with higher grades of villous atrophy. CONCLUSIONS: Overall sensitivity was at or below 90%, which is lower than that reported in the literature. Performance of the recombinant and red blood cell antigen-based tTG assays was similar, whereas the alpha-DGP assays demonstrated lower values. Receiver operating characteristic plot derived cut-off values altered test results. Many factors affect the results of these tests and clinicians should be aware of their limitations.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1097/mcg.0b013e31816200e5

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

Metadata

Authors
Naiyer, A. J., Hernandez, L., Ciaccio, E. J., Papadakis, K., Manavalan, J. S., Bhagat, G., & Green, P. H. R.
Venue
Journal of Clinical Gastroenterology
Published
2009-03
Volume
43
Issue
3
Pages
225-232
ISSN
0192-0790 (ISSN-L)
OpenAlex
W2164377549
Cited by
80
References
0
FWCI
8.33
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.