CoChat

Benefits of breath hydrogen testing after lactulose administration in analysing carbohydrate malabsorption

Bate, John P., Irving, Peter M., Barrett, Jacqueline S., Gibson, Peter R. · 2010 · European Journal of Gastroenterology & Hepatology
Cited by 72

The DOI matches its Crossref record; 5 of the 5 references it cites were found in a registry or an index.

Abstract

BACKGROUND AND AIMS: Breath hydrogen testing after lactulose administration may yield findings of clinical value, but whether it should be a routine part of breath testing has not been evaluated. We examined the contribution of breath testing after lactulose administration to the conduct and interpretation of breath hydrogen responses after fructose and lactose administration. METHODS: Two hundred consecutive patients were given lactulose, fructose or lactose on separate days (at least 2 days apart); breath hydrogen was monitored every 15 min after the administration of each sugar. RESULTS: Peak breath hydrogen levels after lactulose administration correlated with those after fructose (r = 0.26; P = 0.03) and lactose (r = 0.44; P = 0.004). Of the patients with a reduced response to lactulose, 51% had definite or borderline evidence of fructose malabsorption (FM); similarly, 23% of patients had definite or borderline lactose malabsorption. After lactulose administration, an increase in breath hydrogen levels occurred after the same amount of time or longer than after the administration of fructose or lactose (>120 min). The earlier the first rise in breath hydrogen levels after lactulose administration, the more frequently FM occurred, indicating an association between FM and rapid transit and/or small intestinal bacterial overgrowth. CONCLUSION: Routine breath hydrogen testing with lactulose administration before other sugars cannot be used to define non-hydrogen producers, but might, by indicating the vigour of hydrogen production in the individual, allow more rational interpretation of results after testing with other sugars. It permits the duration of testing to be judged and provides information on possible mechanisms of FM.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1097/meg.0b013e32832b20e8

Cites

5 of 5 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 5 references

Cited by

See all 72

Metadata

Authors
Bate, J. P., Irving, P. M., Barrett, J. S., & Gibson, P. R.
Venue
European Journal of Gastroenterology & Hepatology
Published
2010-03
Volume
22
Issue
3
Pages
318-326
ISSN
0954-691X (ISSN-L)
OpenAlex
W2161935396
Cited by
72
References
5
FWCI
2.35
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Benefits of breath hydrogen testing after lactulose administration in analysing carbohydrate malabsorption. https://app.cochat.ai/papers/10.1097/meg.0b013e32832b20e8
The paper
Bate, J. P., Irving, P. M., Barrett, J. S., & Gibson, P. R. (2010). Benefits of breath hydrogen testing after lactulose administration in analysing carbohydrate malabsorption. European Journal of Gastroenterology & Hepatology. https://doi.org/10.1097/meg.0b013e32832b20e8

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.