Optical Stimulation of the Facial Nerve: A New Monitoring Technique?
Open accessThe DOI matches its Crossref record.
Abstract
Objectives/ Hypothesis: One sequela of skull base surgery is iatrogenic damage to cranial nerves, which can be prevented if the nerve is identified. Devices that stimulate nerves with electric current assist in nerve identification. Contemporary devices have two main limitations: 1) the physical contact of the stimulating electrode and (2) the spread of the current through the tissue. In contrast to electrical stimulation, pulsed infrared optical radiation can be used to safely and selectively stimulate neural tissue and might be valuable for screening. Methods: The gerbil facial nerve was exposed to 250 microsecond pulses of 2.12 μm radiation delivered via a 600‐μm‐diameter optical fiber at a repetition rate of 2 Hz. With use of 27 GA, 12‐mm intradermal electrodes, muscle action potentials were recorded. Nerve samples were examined for possible tissue damage. Results: Eight facial nerves were stimulated with radiant exposures between 0.71 and 1.77 J/cm 2, resulting in compound muscle action potentials (CmAPs) that were simultaneously measured at the m. orbicularis oculi, m. levator nasolabialis, and m. orbicularis oris. Resulting CmAP amplitudes were 0.3 to 0.4 mV, 0.15 to 1.4 mV, and 0.3 to 2.3 mV, respectively, depending on the radial location of the optical fiber and the radiant exposure. Individual nerve branches were also stimulated, resulting in CmAP amplitudes between 0.2 and 1.6 mV. Histology revealed tissue damage at radiant exposures of 2.2 J/cm 2 but no apparent damage at radiant exposures of 2.0 J/cm 2. Conclusions: The experiments showed that selective muscle action potentials can be evoked optically in the gerbil facial nerve without direct physical contact.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Light in diagnosis, therapy and surgery
Yun, S. H., & Kwok, S. J. J. (2017) · Nature Biomedical Engineering · doi:10.1038/s41551-016-0008 · Cited by 793
Infrared light excites cells by changing their electrical capacitance
Shapiro, M. G., Homma, K., Villarreal, S., Richter, C.-P., & Bezanilla, F. (2012) · Nature Communications · doi:10.1038/ncomms1742 · Cited by 611
Self-citationTRPV4 channels mediate the infrared laser-evoked response in sensory neurons
Albert, E. S., Bec, J. M., Desmadryl, G., Chekroud, K., Travo, C., Gaboyard, S., Bardin, F., Marc, I., Dumas, M., Lenaers, G., et al. (2012) · Journal of Neurophysiology · doi:10.1152/jn.00424.2011 · Cited by 237
“2008), and facial nerve (Teudt et al. 2007) without tissue damage.”
BackgroundOptical Stimulation of Neurons
C. Thompson, A., R. Stoddart, P., & Jansen, E. D. (2015) · Current Molecular Imaging · doi:10.2174/2211555203666141117220611 · Cited by 105
“Teudt [60] Gerbil facial nerve 2120 710 0.”
BackgroundCombined optical and electrical stimulation of neural tissue in vivo
Duke, A. R., Cayce, J. M., Malphrus, J. D., Konrad, P., Mahadevan-Jansen, A., & Jansen, E. D. (2009) · Journal of Biomedical Optics · doi:10.1117/1.3257230 · Cited by 76
Metadata
- Authors
- Teudt, I. U., Nevel, A. E., Izzo, A. D., Walsh, J. T., & Richter, C.
- Venue
- The Laryngoscope
- Publisher
- Wiley
- Published
- 2007-09
- Volume
- 117
- Issue
- 9
- Pages
- 1641-1647
- ISSN
- 0023-852X (ISSN-L)
- 1531-4995
- OpenAlex
- W2028933152
- Cited by
- 120
- References
- 0
- FWCI
- 3.36
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Optical Stimulation of the Facial Nerve: A New Monitoring Technique? https://app.cochat.ai/papers/10.1097/mlg.0b013e318074ec00
- The paper
- Teudt, I. U., Nevel, A. E., Izzo, A. D., Walsh, J. T., & Richter, C. (2007). Optical Stimulation of the Facial Nerve: A New Monitoring Technique? The Laryngoscope. https://doi.org/10.1097/mlg.0b013e318074ec00
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.