Student or educator? Sign up with your school email and get 6 months of Pro free.
CoChat
Cited by 175

The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.

Review of functional/anatomical imaging in oncology

Open access
Histed, Stephanie N., Lindenberg, Maria L., Mena, Esther, Turkbey, Baris, Choyke, Peter L., Kurdziel, Karen A. · 2012 · Nuclear Medicine Communications

Abstract

Patient management in oncology increasingly relies on imaging for diagnosis, response assessment, and follow-up. The clinical availability of combined functional/anatomical imaging modalities, which integrate the benefits of visualizing tumor biology with those of high-resolution structural imaging, revolutionized clinical management of oncologic patients. Conventional high-resolution anatomical imaging modalities such as computed tomography (CT) and MRI excel at providing details on lesion location, size, morphology, and structural changes to adjacent tissues; however, these modalities provide little insight into tumor physiology. With the increasing focus on molecularly targeted therapies, imaging radiolabeled compounds with PET and single-photon emission tomography (SPECT) is often carried out to provide insight into a tumor's biological functions and its surrounding microenvironment. Despite their high sensitivity and specificity, PET and SPECT alone are substantially limited by low spatial resolution and inability to provide anatomical detail. Integrating SPECT or PET with a modality capable of providing these (i.e. CT or MR) maximizes their separate strengths and provides anatomical localization of physiological processes with detailed visualization of a tumor's structure. The availability of multimodality (hybrid) imaging with PET/CT, SPECT/CT, and PET/MR improves our ability to characterize lesions and affect treatment decisions and patient management. We have just begun to exploit the truly synergistic capabilities of multimodality imaging. Continued advances in the development of instrumentation and imaging agents will improve our ability to noninvasively characterize disease processes. This review will discuss the evolution of hybrid imaging technology and provide examples of its current and potential future clinical uses.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1097/mnm.0b013e32834ec8a5

Cites

2 of 2 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 2 references

Cited by

See all 175

Metadata

Authors
Histed, S. N., Lindenberg, M. L., Mena, E., Turkbey, B., Choyke, P. L., & Kurdziel, K. A.
Venue
Nuclear Medicine Communications
Published
2012-04
Volume
33
Issue
4
Pages
349-361
ISSN
0143-3636 (ISSN-L)
OpenAlex
W1990050702
Cited by
175
References
2
FWCI
14.24
Type
journal article
Language
en
Open access
green

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Review of functional/anatomical imaging in oncology. https://app.cochat.ai/papers/10.1097/mnm.0b013e32834ec8a5
The paper
Histed, S. N., Lindenberg, M. L., Mena, E., Turkbey, B., Choyke, P. L., & Kurdziel, K. A. (2012). Review of functional/anatomical imaging in oncology. Nuclear Medicine Communications. https://doi.org/10.1097/mnm.0b013e32834ec8a5

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.