Vision Performance With a Contact Lens Designed to Slow Myopia Progression
The DOI matches its Crossref record; 37 of the 38 references it cites were found in a registry or an index, and 1 are not checked yet.
Abstract
Purpose: Recent research suggests multizone/dual‐focus (DF) lens corrections may aid in controlling the progression of myopia. Recently, such a soft contact lens has become commercially available in Hong Kong (MiSight, CooperVision). The purpose of the current study was to evaluate the visual acceptability of this new lens design. Methods: In a double‐masked, randomized, crossover trial, 24 subjects (aged 18 to 25 years) wore MiSight contact lenses and Proclear Multifocal +2.00 diopters Add D (MF) soft contact lenses. Patient‐reported outcomes (0 to 100 scale) and objective measures of visual performance were acquired for best‐spectacle distance correction (BC) and with each contact lens after 1 week of daily use at HIHC (high illumination–high contrast) at distance and LILC (low illumination–low contrast) at distance, intermediate, and near. Results: There were no significant differences in HIHC distance acuity between BC and either the DF or MF lens and no difference between the DF and MF lenses. However, when measured under LILC, there were significant mean differences between each study lens and BC viewed at distance and intermediate. The LILC logMAR visual acuity was not significantly different between the DF and MF lenses at any viewing distance. Although average visual quality and ghosting ratings for both DF and MF study lenses were significantly lower than habitual under all conditions, there were no significant differences between the DF and MF lenses (p = 0.448). Conclusions: Good acuity, similar to that attainable with typical MF lens correction, is attainable with a new contact lens designed to control myopia progression. However, like other contact lenses that contain multiple refractive zones, some decrease in visual performance may be experienced.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“Adaptation appears faster, and patient satisfaction is higher with FFLs”
From Freeform vs. Aspheric Spectacle Lenses: A Comprehensive Review of Optical Performance, Clinical Outcomes, and Patient Considerations (2026) · cites this paper as [56]
Citations
Cites
Increased Prevalence of Myopia in the United States Between 1971-1972 and 1999-2004
Vitale, S. (2009) · Archives of Ophthalmology · doi:10.1001/archophthalmol.2009.303 · Cited by 906
Effect of Dual-Focus Soft Contact Lens Wear on Axial Myopia Progression in Children
Anstice, N. S., & Phillips, J. R. (2011) · Ophthalmology · doi:10.1016/j.ophtha.2010.10.035 · Cited by 422
Sankaridurg, P., Holden, B., Smith, E., Naduvilath, T., Chen, X., de la Jara, P. L., Martinez, A., Kwan, J., Ho, A., Frick, K., et al. (2011) · Investigative Opthalmology & Visual Science · doi:10.1167/iovs.11-7260 · Cited by 394
Low-Contrast Letter Charts as a Test of Visual Function
Regan, D., & Neima, D. (1983) · Ophthalmology · doi:10.1016/s0161-6420(83)34407-9 · Cited by 210
Comparison of the effect of atropine and cyclopentolate on myopia.
Yen, M., Liu, J., Kao, S.-C., & Shiao, C.-H. (1989) · PubMed · Cited by 208
Dayan, Y. B., Levin, A., Morad, Y., Grotto, I., Ben-David, R., Goldberg, A., Onn, E., Avni, I., Levi, Y., & Benyamini, O. G. (2005) · Investigative Opthalmology & Visual Science · doi:10.1167/iovs.04-0260 · Cited by 200
A Randomized Trial of the Effects of Rigid Contact Lenses on MyopiaProgression
Walline, J. J. (2004) · Archives of Ophthalmology · doi:10.1001/archopht.122.12.1760 · Cited by 185
Refractive Error, Axial Dimensions, and Primary Open-Angle Glaucoma: The Singapore Malay Eye Study
Perera, S. (2010) · Archives of Ophthalmology · doi:10.1001/archophthalmol.2010.125 · Cited by 182
Progression of Myopia in Hong Kong Chinese Schoolchildren Is Slowed by Wearing Progressive Lenses
Leung, J., & Brown, B. H. (1999) · Optometry and Vision Science · doi:10.1002/j.1538-9235.1999.tb05413.x · Cited by 179
Rose, K. (2000) · British Journal of Ophthalmology · doi:10.1136/bjo.84.9.1031 · Cited by 172
Research works printed but not linked: 3
- Douthwaite W, 2006, Contact Lens Optics and Lens Design
- Winer BL, 1971, Statistical Principles in Experimental Design
- Sheedy JE, 1993, Does the presbyopic visual system adapt to contact lenses?, Optom Vis Sci, 70, 482, 10.1097/00006324-199306000-00006 · doi:10.1097/00006324-199306000-00006
Cited by
IMI Prevention of Myopia and Its Progression
Jonas, J. B., Ang, M., Cho, P., Guggenheim, J. A., He, M. G., Jong, M., Logan, N. S., Liu, M., Morgan, I., Ohno-Matsui, K., et al. (2021) · Investigative Opthalmology & Visual Science · doi:10.1167/iovs.62.5.6 · Cited by 475
Myopic maculopathy: Current status and proposal for a new classification and grading system (ATN)
Ruiz-Medrano, J., Montero, J. A., Flores-Moreno, I., Arias, L., García-Layana, A., & Ruiz-Moreno, J. M. (2019) · Progress in Retinal and Eye Research · doi:10.1016/j.preteyeres.2018.10.005 · Cited by 446
MiSight Assessment Study Spain (MASS). A 2-year randomized clinical trial
Ruiz‐Pomeda, A., Pérez-Sánchez, B. B., Valls, I., Prieto-Garrido, F. L., Gutiérrez-Ortega, R., & Villa-Collar, C. C. (2018) · Graefe s Archive for Clinical and Experimental Ophthalmology · doi:10.1007/s00417-018-3906-z · Cited by 208
Li, S., Kang, M., Wu, S., Meng, B., Sun, Y., Wei, S., Liu, L.-R., Peng, X., Chen, Z., Zhang, F., et al. (2016) · Ophthalmic and Physiological Optics · doi:10.1111/opo.12332 · Cited by 164
IMI—Onset and Progression of Myopia in Young Adults
Bullimore, M. A., Lee, S. S., Schmid, K. L., Rozema, J. J., Leveziel, N., Mallen, E. A. H., Jacobsen, N., Iribarren, R., Verkicharla, P. K., Polling, J. R., et al. (2023) · Investigative Ophthalmology & Visual Science · doi:10.1167/iovs.64.6.2 · Cited by 154
Contact lenses to slow progression of myopia
Sankaridurg, P. R. (2017) · Clinical and Experimental Optometry · doi:10.1111/cxo.12584 · Cited by 102
Peripheral Defocus with Spherical and Multifocal Soft Contact Lenses
Berntsen, D. A., & Kramer, C. E. (2013) · Optometry and Vision Science · doi:10.1097/opx.0000000000000066 · Cited by 100
Accommodation and Phoria in Children Wearing Multifocal Contact Lenses
Gong, C. R., Troilo, D., & Richdale, K. (2017) · Optometry and Vision Science · doi:10.1097/opx.0000000000001044 · Cited by 92
Visual performance of single vision and multifocal contact lenses in non-presbyopic myopic eyes
Fedtke, C., Bakaraju, R. C., Ehrmann, K., Chung, J., Thomas, V., & Holden, B. A. (2015) · Contact Lens and Anterior Eye · doi:10.1016/j.clae.2015.07.005 · Cited by 86
Kang, P., McAlinden, C., & Wildsoet, C. F. (2016) · Acta Ophthalmologica · doi:10.1111/aos.13173 · Cited by 74
Jaskulski, M., Singh, N. K., Bradley, A., & Kollbaum, P. S. (2020) · Ophthalmic and Physiological Optics · doi:10.1111/opo.12725 · Cited by 66
Self-citationThe impact of spectacle lenses for myopia control on visual functions
Gao, Y., Lim, E. W., Yang, A., Drobe, B., & Bullimore, M. A. (2021) · Ophthalmic and Physiological Optics · doi:10.1111/opo.12878 · Cited by 60
Ruiz‐Pomeda, A., & Villa-Collar, C. C. (2020) · Ophthalmology and Therapy · doi:10.1007/s40123-020-00298-y · Cited by 56
Clinical management of progressive myopia
Aller, T. A. (2013) · Eye · doi:10.1038/eye.2013.259 · Cited by 54
Arumugam, B., Hung, L., To, C. H., Sankaridurg, P. R., & Smith, E. L., III (2016) · Investigative Ophthalmology & Visual Science · doi:10.1167/iovs.16-19704 · Cited by 52
Pomeda, A. R., Pérez-Sánchez, B. B., Cañadas, P., Prieto-Garrido, F. L., Gutiérrez-Ortega, R., & Villa-Collar, C. C. (2017) · Eye & Contact Lens Science & Clinical Practice · doi:10.1097/icl.0000000000000413 · Cited by 48
The Future of Myopia Control Contact Lenses
Gifford, P., & Gifford, K. (2016) · Optometry and Vision Science · doi:10.1097/opx.0000000000000762 · Cited by 47
BCLA CLEAR – Contact lens optics
Richdale, K., Cox, I., Kollbaum, P. S., Bullimore, M. A., Bakaraju, R. C., Gifford, P., Plainis, S., McKenney, C., Newman, S., Tomiyama, E. S., et al. (2021) · Contact Lens and Anterior Eye · doi:10.1016/j.clae.2021.02.005 · Cited by 46
Self-citationGarcía‐Marqués, J. V., Macedo-de-Araújo, R. J., Cerviño, A., García‐Lázaro, S., McAlinden, C., & González‐Méijome, J. M. (2020) · Ophthalmic and Physiological Optics · doi:10.1111/opo.12729 · Cited by 46
Visual performance of myopia control soft contact lenses in non-presbyopic myopes
Sha, J., Tilia, D., Diec, J., Fedtke, C., Yeotikar, N. S., Jong, M., Thomas, V., & Bakaraju, R. C. (2018) · Clinical Optometry · doi:10.2147/opto.s167297 · Cited by 46
Vision-related quality of life with myopia management: A review
Lipson, M. J., Boland, B., & McAlinden, C. (2021) · Contact Lens and Anterior Eye · doi:10.1016/j.clae.2021.101538 · Cited by 41
Visual Acuity and Over‐refraction in Myopic Children Fitted with Soft Multifocal Contact Lenses
Schulle, K. L., Berntsen, D. A., Sinnott, L. T., Bickle, K. M., Tićak, A., Pierce, G. E., Jones‐Jordan, L. A., Mutti, D. O., Walline, J. J., & for The Bifocal Lenses in Nearsighted Kids (BLINK) Study Group (2018) · Optometry and Vision Science · doi:10.1097/opx.0000000000001207 · Cited by 40
Pauné, J., Queirós, A., Junyent, L. Q. I., Neves, H., Lopes-Ferreira, D., & González‐Méijome, J. M. (2014) · Contact Lens and Anterior Eye · doi:10.1016/j.clae.2014.08.001 · Cited by 37
Ji, Q., Yoo, Y., Alam, H., & Yoon, G. (2018) · Ophthalmic and Physiological Optics · doi:10.1111/opo.12452 · Cited by 35
Bifocal & Atropine in Myopia Study: Baseline Data and Methods
Huang, J., Mutti, D. O., Jones‐Jordan, L. A., & Walline, J. J. (2019) · Optometry and Vision Science · doi:10.1097/opx.0000000000001378 · Cited by 35
Validation of a Clinical Aberrometer Using Pyramidal Wavefront Sensing
Singh, N. K., Jaskulski, M., Ramasubramanian, V., Meyer, D., Reed, O., Rickert, M. E., Bradley, A., & Kollbaum, P. S. (2019) · Optometry and Vision Science · doi:10.1097/opx.0000000000001435 · Cited by 35
Self-citationVisual Performance of Center‐distance Multifocal Contact Lenses Fit Using a Myopia Control Paradigm
Gregory, H. R., Nti, A. N., Wolffsohn, J. S., Berntsen, D. A., & Ritchey, E. R. (2021) · Optometry and Vision Science · doi:10.1097/opx.0000000000001665 · Cited by 33
Association between multifocal soft contact lens decentration and visual performance
Bakaraju, R. C., Ehrmann, K., Thomas, V., & Fedtke, C. (2016) · Clinical Optometry · doi:10.2147/opto.s108528 · Cited by 29
Martins, C., Amorim‐de‐Sousa, A., Faria‐Ribeiro, M. Á., Pauné, J., González‐Méijome, J. M., & Queirós, A. (2019) · Current Eye Research · doi:10.1080/02713683.2019.1645182 · Cited by 29
Contrast Sensitivity with Center‐distance Multifocal Soft Contact Lenses
Nti, A. N., Gregory, H. R., Ritchey, E. R., Wolffsohn, J. S., & Berntsen, D. A. (2022) · Optometry and Vision Science · doi:10.1097/opx.0000000000001874 · Cited by 28
Predicting Short-Term Subjective Vision Performance of Contact Lenses Used in Myopia Control
Diec, J., Tilia, D., Thomas, V., & Bakaraju, R. C. (2017) · Eye & Contact Lens Science & Clinical Practice · doi:10.1097/icl.0000000000000460 · Cited by 27
Advances and challenges of soft contact lens design for myopia control
Li, Q., & Fang, F. (2019) · Applied Optics · doi:10.1364/ao.58.001639 · Cited by 27
Tilia, D., Sha, J., Thomas, V., & Bakaraju, R. C. (2019) · Eye & Contact Lens Science & Clinical Practice · doi:10.1097/icl.0000000000000570 · Cited by 26
Short-Term Adaptation of Accommodative Responses in Myopes Fitted With Multifocal Contact Lenses
Ozkan, J., Fedtke, C., Chung, J., Thomas, V., & Bakaraju, R. C. (2016) · Eye & Contact Lens Science & Clinical Practice · doi:10.1097/icl.0000000000000299 · Cited by 25
Yu, Z., Zhong, A., Zhao, X., Li, D., & Duan, J. (2022) · Ophthalmic Research · doi:10.1159/000523675 · Cited by 23
Ruiz‐Pomeda, A., Fernandes, P. R. B., Amorim‐de‐Sousa, A., González‐Méijome, J. M., Prieto-Garrido, F. L., Pérez-Sánchez, B. B., & Villa-Collar, C. C. (2018) · Contact Lens and Anterior Eye · doi:10.1016/j.clae.2018.11.006 · Cited by 23
Visual Performance with Spherical and Multifocal Contact Lenses in a Pediatric Population
Bickle, K. M., Mitchell, G. L., & Walline, J. J. (2021) · Optometry and Vision Science · doi:10.1097/opx.0000000000001695 · Cited by 21
Gao, Y., Lim, E. W., & Drobe, B. (2023) · Ophthalmic and Physiological Optics · doi:10.1111/opo.13127 · Cited by 20
Visual quality of juvenile myopes wearing multifocal soft contact lenses
Huang, X., Wang, F., Lin, Z., He, Y., Wen, S., Zhou, L. X., Lü, F., & Jiang, J. (2020) · Eye and Vision · doi:10.1186/s40662-020-00204-4 · Cited by 19
Retinal defocus in myopes wearing dual‐focus zonal contact lenses
Singh, N. K., Meyer, D., Jaskulski, M., & Kollbaum, P. S. (2021) · Ophthalmic and Physiological Optics · doi:10.1111/opo.12903 · Cited by 18
Self-citationMojarrad, N. G., Hussain, M., Mankowska, A., Mallen, E. A. H., & Cufflin, M. (2023) · Contact Lens and Anterior Eye · doi:10.1016/j.clae.2023.102095 · Cited by 18
Hair, L. A., Steffensen, E. M., & Berntsen, D. A. (2021) · Optometry and Vision Science · doi:10.1097/opx.0000000000001753 · Cited by 18
Weng, R., Naduvilath, T. J., Philip, K., Chen, X., & Sankaridurg, P. R. (2020) · Contact Lens and Anterior Eye · doi:10.1016/j.clae.2020.11.015 · Cited by 18
MiSight Assessment Study Spain: Adverse Events, Tear Film Osmolarity, and Discontinuations
Ruiz‐Pomeda, A., Pérez-Sánchez, B. B., Prieto-Garrido, F. L., Gutiérrez-Ortega, R., & Villa-Collar, C. C. (2018) · Eye & Contact Lens Science & Clinical Practice · doi:10.1097/icl.0000000000000484 · Cited by 18
Schmid, K. L., Gifford, K., & Atchison, D. A. (2022) · Contact Lens and Anterior Eye · doi:10.1016/j.clae.2022.101588 · Cited by 17
Song, D., Qiu, W., Jiang, T., Chen, Z., & Chen, J. (2024) · BMC Ophthalmology · doi:10.1186/s12886-024-03408-7 · Cited by 16
Vera, J., Redondo, B., Galán, T., Machado, P., Molina, R., Koulieris, G. A., & Jiménez, R. (2021) · Contact Lens and Anterior Eye · doi:10.1016/j.clae.2021.101526 · Cited by 16
García‐Marqués, J. V., Macedo-de-Araújo, R. J., McAlinden, C., Faria‐Ribeiro, M. Á., Cerviño, A., & González‐Méijome, J. M. (2022) · Ophthalmic and Physiological Optics · doi:10.1111/opo.13024 · Cited by 16
Tear film stability over a myopia control contact lens compared to a monofocal design
García‐Marqués, J. V., Macedo-de-Araújo, R. J., Lopes-Ferreira, D., Cerviño, A., García‐Lázaro, S., & González‐Méijome, J. M. (2021) · Clinical and Experimental Optometry · doi:10.1080/08164622.2021.1878864 · Cited by 16
Fedtke, C., Ehrmann, K., Thomas, V., & Bakaraju, R. C. (2016) · Clinical Optometry · doi:10.2147/opto.s96712 · Cited by 16
Assessment of Clinical Trials for Devices Intended to Control Myopia Progression in Children
Robboy, M. W., Hilmantel, G., Tarver, M. E., & Eydelman, M. B. (2018) · Eye & Contact Lens Science & Clinical Practice · doi:10.1097/icl.0000000000000476 · Cited by 16
The Relationship Between Vision and Comfort in Contact Lens Wear
Diec, J., Naduvilath, T. J., Tilia, D., & Bakaraju, R. C. (2020) · Eye & Contact Lens Science & Clinical Practice · doi:10.1097/icl.0000000000000743 · Cited by 16
Redondo, B., Vera, J., Molina, R., Galán, T., Machado, P., & Jiménez, R. (2022) · Ophthalmic and Physiological Optics · doi:10.1111/opo.12978 · Cited by 14
Myopia Control Dose Delivered to Treated Eyes by a Dual‐focus Myopia‐control Contact Lens
Ramasubramanian, V., Logan, N. S., Jones, S., Meyer, D., Jaskulski, M., Rickert, M. E., Chamberlain, P., Arumugam, B., Bradley, A., & Kollbaum, P. S. (2023) · Optometry and Vision Science · doi:10.1097/opx.0000000000002021 · Cited by 14
Self-citationSah, R. P., Jaskulski, M., & Kollbaum, P. S. (2022) · Ophthalmic and Physiological Optics · doi:10.1111/opo.12959 · Cited by 14
Self-citationChen, S.-T., Tung, H.-C., Chen, Y., Tien, C., Yeh, C.-W., Lian, J.-S., & Cheng, C. (2022) · Scientific Reports · doi:10.1038/s41598-022-10580-7 · Cited by 13
On‐eye centration of soft contact lenses
Walther, G., Meyer, D., Richards, J., Rickert, M. E., & Kollbaum, P. S. (2024) · Ophthalmic and Physiological Optics · doi:10.1111/opo.13278 · Cited by 13
Self-citationWagner, S., Schaeffel, F., & Troilo, D. (2020) · Scientific Reports · doi:10.1038/s41598-020-61904-4 · Cited by 12
Tilia, D., Diec, J., Ehrmann, K., Falk, D., Fedtke, C., Conrad, F., Wu, R., & Bakaraju, R. C. (2022) · Eye & Contact Lens Science & Clinical Practice · doi:10.1097/icl.0000000000000950 · Cited by 12
The Effect of Fractal Contact Lenses on Peripheral Refraction in Myopic Model Eyes
Rodríguez‐Vallejo, M., Benlloch, J., Pons, A., Monsoriu, J. A., & Furlan, W. D. (2014) · Current Eye Research · doi:10.3109/02713683.2014.903498 · Cited by 12
Childhood Myopia Part II: Treatment Mechanisms, Emerging Options, and Considerations
Khanal, S., Tomiyama, E. S., & Harrington, S. C. (2025) · Investigative Ophthalmology & Visual Science · doi:10.1167/iovs.66.7.7 · Cited by 10
Myopia Control With Multifocal Lens in School-Aged Children: A Meta-Analysis
Chen, M.-L., Xu, L., Li, H., Cai, F., Wang, H., Hu, C., & Wu, Y. (2022) · Frontiers in Pediatrics · doi:10.3389/fped.2022.889243 · Cited by 10
Ping, X., Yoshioka, N., Kim, J., & Sankaridurg, P. R. (2024) · Contact Lens and Anterior Eye · doi:10.1016/j.clae.2024.102303 · Cited by 8
Centration assessment of an extended depth of focus contact lens for myopic progression control
Rizzo, G. C., Vizio, A. D., Versaci, F., Przekoracka, K., Tavazzi, S., & Zeri, F. (2021) · Contact Lens and Anterior Eye · doi:10.1016/j.clae.2021.101533 · Cited by 8
International trends in prescribing contact lenses for myopia control (2011–2024): An update
Efron, N., Morgan, P. B., Woods, C. A., JONES, D. A., Jones, L., Santodomingo‐Rubido, J., & Nichols, J. J. (2025) · Contact Lens and Anterior Eye · doi:10.1016/j.clae.2025.102451 · Cited by 8
Tahhan, N., Naduvilath, T. J., & Tilia, D. (2023) · Ophthalmic and Physiological Optics · doi:10.1111/opo.13102 · Cited by 8
Tićak, A., Walline, J. J., Berntsen, D. A., Mutti, D. O., Jones‐Jordan, L. A., Cardenas, L., Day, E., Dougherty, B. E., & The BLINK Study Group (2023) · Ophthalmic and Physiological Optics · doi:10.1111/opo.13216 · Cited by 8
Meyer, D., Gantes-Nuñez, F. J., Rickert, M. E., Murthy, N., Chamberlain, P., Bradley, A., & Kollbaum, P. S. (2024) · Ophthalmic and Physiological Optics · doi:10.1111/opo.13420 · Cited by 7
Self-citationCorpus, G., & Pinero, D. P. (2022) · Applied Sciences · doi:10.3390/app12010431 · Cited by 7
Tilia, D., Diec, J., Sha, J., Lahav-Yacouel, K., Ehrmann, K., Fedtke, C., & Bakaraju, R. C. (2025) · Optometry and Vision Science · doi:10.1097/opx.0000000000002253 · Cited by 7
The influence of high addition soft multifocal contact lenses on visual performance
Kropacz-Sobkowiak, S., Przekoracka‐Krawczyk, A., Michalak, K. P., Michalski, A., Kujawa, K., & Olszewski, J. (2020) · Klinika Oczna · doi:10.5114/ko.2020.94754 · Cited by 7
Chen, Y., Ding, C., Li, X., Huang, Y., Zhou, F., Drobe, B., Chen, H., & Bao, J. (2023) · Ophthalmic and Physiological Optics · doi:10.1111/opo.13144 · Cited by 6
The Impact of Myopia Control Spectacle Lens Designs on Visual Function
Desiato, A., Lam, H. Y., Anand, R. R., Chatha, I., Logan, N., Sheppard, A. L., Wolffsohn, J. S., Laughton, D. S., & Davies, L. N. (2026) · Ophthalmic and Physiological Optics · doi:10.1007/s44402-026-00026-2 · Cited by 6
Singh, N. K., & Kollbaum, P. S. (2025) · Ophthalmic and Physiological Optics · doi:10.1111/opo.13533 · Cited by 5
Self-citationImpact of dual-focus soft contact lens wear on near work-induced transient myopia
Jiménez, R., Redondo, B., Galán, T., Machado, P., Molina, R., & Vera, J. (2022) · Clinical and Experimental Optometry · doi:10.1080/08164622.2022.2029684 · Cited by 5
2-D Peripheral image quality metrics with different types of multifocal contact lenses
García, M. G., Wahl, S., Pusti, D., Artal, P., & Ohlendorf, A. (2019) · Scientific Reports · doi:10.1038/s41598-019-54783-x · Cited by 6
Bifocal Lenses in Nearsighted Kids (BLINK) Study
Bickle, K. M. (2013) · OhioLink ETD Center (Ohio Library and Information Network) · Cited by 5
Signes‐Soler, I., Sivera, S. R., Cantó-Vañó, J., Giménez-Sanchís, I., & Albarrán‐Diego, C. (2023) · Journal of Ophthalmic and Vision Research · doi:10.18502/jovr.v18i4.14544 · Cited by 4
Visual performance of optical films utilizing Spatio‐Temporal Optical Phase technology
Fedtke, C., Tilia, D., Ehrmann, K., Diec, J., Lahav-Yacouel, K., Falk, D., & Bakaraju, R. C. (2024) · Optometry and Vision Science · doi:10.1097/opx.0000000000002121 · Cited by 4
Optical characterisation and vision quality assessment of two myopia control contact lenses
Richards, J., Jaskulski, M., Woods, J., Guthrie, S., & Kollbaum, P. S. (2025) · Ophthalmic and Physiological Optics · doi:10.1111/opo.13521 · Cited by 4
Self-citationIntraocular Straylight and Multifocal Soft Contact Lens Fit With a Myopia Control Approach
Ritchey, E. R., Gregory, H. R., Nti, A. N., & Berntsen, D. A. (2024) · Eye & Contact Lens Science & Clinical Practice · doi:10.1097/icl.0000000000001069 · Cited by 3
Chen, Y., Yang, B., Kou, J., & Liu, L. (2024) · PubMed Central · doi:10.12182/20240960507 · Cited by 3
Nieto, L. V., Novo‐Diez, A., Mangas-Alonso, M., Rojas-López, A., la Rosa, A. L., & López‐Miguel, A. (2023) · Eye & Contact Lens Science & Clinical Practice · doi:10.1097/icl.0000000000001052 · Cited by 3
Sankaridurg, P. R. (2023) · Elsevier eBooks · doi:10.1016/b978-0-7020-8427-0.00031-3 · Cited by 2
Kubota, R., Joshi, N. R., Samandarova, I., Oliva, M., Selenow, A., Gupta, A., Ali, S. R., & Ciuffreda, K. J. (2021) · Optometry and Vision Science · doi:10.1097/opx.0000000000001750 · Cited by 2
German Society of Ophthalmology (2019) · Der Ophthalmologe · doi:10.1007/s00347-019-00953-1 · Cited by 2
Diec, J., Tilia, D., Sha, J., Lahav-Yacouel, K., Ehrmann, K., Fedtke, C., & Bakaraju, R. C. (2026) · Clinical and Experimental Optometry · doi:10.1080/08164622.2026.2620554 · Cited by 2
Mechó‐García, M., Fernandes, P., González‐Méijome, J. M., & Faria‐Ribeiro, M. Á. (2025) · Biomedical Optics Express · doi:10.1364/boe.549285 · Cited by 2
A look at literature on myopia over the past 25 years: a personal review
Michaud, L., Marcotte-Collard, R., & Simard, P. (2025) · Clinical and Experimental Optometry · doi:10.1080/08164622.2025.2579173 · Cited by 1
Caracteritzación teórica de un ojo miope joven según la refracción periférica
Bello, B. R. (2014) · LA Referencia (Red Federada de Repositorios Institucionales de Publicaciones Científicas) · Cited by 1
(BVA), B. D. A. D. E. V., & Gesellschaft, D. O. (2019) · Der Ophthalmologe · doi:10.1007/s00347-019-0874-6 · Cited by 1
Rosado, M. O., Júnior, R. M. G., Teixeira, J. P. C. R., Basílio, I. G., Fraga, M. S. G., Ferreira, B. C., Caixeta, F. A. M., Pascoal, H. F. P., de Souza, L. G. P., João, M. A. S., et al. (2024) · Brazilian Journal of Health Review · doi:10.34119/bjhrv7n5-040 · Cited by 1
The effect of pupil size on visual performance with center‐distance soft multifocal contact lenses
Dolce, J. C., Nti, A. N., & Berntsen, D. A. (2025) · Optometry and Vision Science · doi:10.1097/opx.0000000000002271 · Cited by 1
Liou, J.-C., Chen, P.-H., Tung, H.-C., Tung, T.-Y., Chang, C.-W., & Cheng, C. (2026) · Contact Lens and Anterior Eye · doi:10.1016/j.clae.2026.102657 · Cited by 1
Wolffsohn, J. S., & Morgan, P. B. (2026) · Contact Lens and Anterior Eye · doi:10.1016/j.clae.2026.102697 · Cited by 1
Gregory, H. R., Nti, A. N., Wolffsohn, J. S., Berntsen, D. A., & Ritchey, E. R. (2021) · Optometry and Vision Science · doi:10.1097/opx.0000000000001760 · Cited by 1
Calidad óptica con diferentes tipos de lentes de contacto para el control de la miopía
Bilba, A., Martín, L. R., & Marcellán Vidosa, M. C. (2019) · Zaguan (Universidad de Zaragoza) · Cited by 1
Ladopoulos, K., Pateras, E., & Ninos, G. (2026) · Cureus · doi:10.7759/cureus.104008
“The FFLs are associated with shorter adaptation time, especially in first-time PAL wearers and those switching from a simpler design, and a greater frequency of immediately comfortable vision [54-56].”
Pauné, J. (2015) · UPCommons institutional repository (Universitat Politècnica de Catalunya) · doi:10.5821/dissertation-2117-95987
Peripheral Refractive Error in Multifocal Contact Lenses
Smith, M. (2016) · OhioLink ETD Center (Ohio Library and Information Network)
Metadata
- Authors
- Kollbaum, P. S., Jansen, M. E., Tan, J., Meyer, D. M., & Rickert, M. E.
- Affiliations
- Indiana University Bloomington (US)
- Sydney New South Wales Australia
- Corresponding author
- Kollbaum, Pete S.
- Venue
- Optometry and Vision Science
- Publisher
- Wiley
- Published
- 2013-03
- Volume
- 90
- Issue
- 3
- Pages
- 205-214
- ISSN
- 1040-5488 (ISSN-L)
- 1538-9235
- OpenAlex
- W2002038873
- Cited by
- 109
- References
- 37
- Citations by year
- 2026: 9 · 2025: 9 · 2024: 8 · 2023: 10 · 2022: 12 · 2021: 13 · 2020: 8 · 2019: 10 · 2018: 9 · 2017: 4 · 2016: 8 · 2015: 3 · 2014: 2 · 2013: 3
- FWCI
- 3.88
- Type
- journal article
- Language
- en
- Open access
- closed
- Licence
- onlinelibrary.wiley.com/termsAndConditions#vor (vor)
- doi.wiley.com/10.1002/tdm_license_1.1 (tdm)
- Locations
- Optometry and Vision Science (publishedVersion)
- PubMed (publishedVersion)
- Funders
- CooperVision
- Topics
- Health Sciences › Medicine › Ophthalmology › Ophthalmology and Visual Impairment Studies
- Health Sciences › Medicine › Ophthalmology › Ocular Surface and Contact Lens
- Health Sciences › Medicine › Ophthalmology › Intraocular Surgery and Lenses
- Keywords
- myopia control, visual performance, visual quality, ghosting, intermediate and near vision, patient-reported outcomes
- MeSH terms
- Adult, Contact Lenses, Hydrophilic, Double-Blind Method, Equipment Design, Female, Follow-Up Studies, Humans, Male, Myopia, Refraction, Ocular, Visual Acuity, Disease Progression, Cross-Over Studies, Young Adult
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.