Recommendations for Improved Standardization of Immunohistochemistry
The DOI matches its Crossref record; 45 of the 45 references it cites were found in a registry or an index.
Abstract
Immunohistochemistry (IHC) continues to suffer from variable consistency, poor reproducibility, quality assurance disparities, and the lack of standardization resulting in poor concordance, validation, and verification. This document lists the recommendations made by the Ad-Hoc Committee on Immunohistochemistry Standardization to address these deficiencies. Contributing factors were established to be underfixation and irregular fixation, use of nonformalin fixatives and ancillary fixation procedures divested from a deep and full understanding of the IHC assay parameters, minimal or absent IHC assay optimization and validation procedures, and lack of a standard system of interpretation and reporting. Definitions and detailed guidelines pertaining to these areas are provided.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Wolff, A. C., Hammond, M. E. H., Schwartz, J. N., Hagerty, K. L., Allred, D. C., Cote, R. J., Dowsett, M., Fitzgibbons, P. L., Hanna, W. M., Langer, A., et al. (2007) · Journal of Clinical Oncology · doi:10.1200/jco.2006.09.2775 · Cited by 4,434
Fox, C. H., Johnson, F. B., Whiting, J., & Roller, P. P. (1985) · Journal of Histochemistry & Cytochemistry · doi:10.1177/33.8.3894502 · Cited by 1,087 · cited 2×
“Although complete tissue fixation requires 24 hours, a minimum of 6 preprocessor hours of formalin fixation is required for consistent IHC assay results.(19,22,23) Nonformalin fixatives and or alternative fixation methodologies are strongly discouraged for several reasons.”
BackgroundHirsch, F. R., Varella-Garcia, M., Bunn, P. A., Franklin, W. A., Dziadziuszko, R., Thatcher, N., Chang, A., Parikh, P., Pereira, J. R., Ciuleanu, T., et al. (2006) · Journal of Clinical Oncology · doi:10.1200/jco.2006.06.3958 · Cited by 703
Taylor, C. R., & Levenson, R. M. (2006) · Histopathology · doi:10.1111/j.1365-2559.2006.02513.x · Cited by 609 · cited 2×
“IHC assay immunoreactivity should be assessed with a quantitative scoring system.(5,84) All scoring systems should have 2 separate components: the extent or proportion of the target antigen that was immunoreactive and the intensity of the immunoreactivity.”
MethodSelf-citationMutations of the human E-cadherin (CDH1) gene
Berx, G., Becker, K.-F., Höfler, H., & van Roy, F. (1998) · Human Mutation · doi:10.1002/(sici)1098-1004(1998)12:4<226::aid-humu2>3.0.co;2-d · Cited by 607
Antigen Retrieval Immunohistochemistry: Past, Present, and Future
Shi, S.-R., Cote, R. J., & Taylor, C. R. (1997) · Journal of Histochemistry & Cytochemistry · doi:10.1177/002215549704500301 · Cited by 516
Self-citationPEComa: what do we know so far?
Hornick, J. L., & Fletcher, C. D. �. (2005) · Histopathology · doi:10.1111/j.1365-2559.2005.02316.x · Cited by 500
Perez, E. A., Suman, V. J., Davidson, N. E., Martino, S., Kaufman, P. A., Lingle, W. L., Flynn, P. J., Ingle, J. N., Visscher, D., & Jenkins, R. B. (2006) · Journal of Clinical Oncology · doi:10.1200/jco.2005.03.4744 · Cited by 438
Antigen Retrieval Techniques: Current Perspectives
Shi, S.-R., Cote, R. J., & Taylor, C. R. (2001) · Journal of Histochemistry & Cytochemistry · doi:10.1177/002215540104900801 · Cited by 335
Self-citationRhodes, A., Jasani, B., Barnes, D. M., Bobrow, L. G., & Miller, K. D. (2000) · Journal of Clinical Pathology · doi:10.1136/jcp.53.2.125 · Cited by 325
Antigen retrieval immunohistochemistry under the influence of pH using monoclonal antibodies.
Shi, S. R., Imam, S. A., Young, L., Cote, R. J., & Taylor, C. R. (1995) · Journal of Histochemistry & Cytochemistry · doi:10.1177/43.2.7822775 · Cited by 307
Self-citationAcs, G., Lawton, T. J., Rebbeck, T. R., LiVolsi, V. A., & Zhang, P. J. (2001) · American Journal of Clinical Pathology · doi:10.1309/fdhx-l92r-batq-2ge0 · Cited by 280
Goldstein, M., Ferkowicz, M., Odish, H., Mani, M., & Hastah, M. (2003) · American Journal of Clinical Pathology · doi:10.1309/qphd-rb00-qxgm-uq9n · Cited by 280
Expression of Melan-A (MART1) in Benign Melanocytic Nevi and Primary Cutaneous Malignant Melanoma
Busam, K. J., Chen, Y.-T., Old, L. J., Stockert, E., Iversen, K., Coplan, K. A., Rosai, J., Barnhill, R. L., & Jungbluth, A. A. (1998) · The American Journal of Surgical Pathology · doi:10.1097/00000478-199808000-00007 · Cited by 234
Kawanishi, J., Kato, J., Sasaki, K., Fujii, S., Watanabe, N., & Niitsu, Y. (1995) · Molecular and Cellular Biology · doi:10.1128/mcb.15.3.1175 · Cited by 220
Mengel, M., von Wasielewski, R., Wiese, B., Rüdiger, T., Müller‐Hermelink, H. K., & Kreipe, H. (2002) · The Journal of Pathology · doi:10.1002/path.1218 · Cited by 213 · cited 1×
“In general, underfixation is a substantially larger problem than overfixation.(43,44) This recommendation plays a key role in standardizing fixation parameters for IHC assays.”
BackgroundHER2 Testing in Breast Cancer: NCCN Task Force Report and Recommendations
Carlson, R. W., Moench, S. J., Hammond, M. E. H., Perez, E. A., Burstein, H. J., Allred, D. C., Vogel, C. L., Goldstein, L. J., Somlo, G., Gradishar, W. J., et al. (2006) · Journal of the National Comprehensive Cancer Network · doi:10.6004/jnccn.2006.2003 · Cited by 205 · cited 1×
“These recommendations are in step with the NCCLS (CLSI) guidelines for HER2 IHC assays that the type of fixative and length of fixation be included in the pathology report.(41,42) Insufficient, inconsistent, and different types of fixation and tissue processing are the key factors behind suboptimal and inconsistent IH…”
MethodInterpretation and Quantification of Immunostains
Seidal, T., Balaton, A. J., & Battifora, H. (2001) · The American Journal of Surgical Pathology · doi:10.1097/00000478-200109000-00013 · Cited by 205
Immunohistochemical detection of steroid receptors in breast cancer: a working protocol: Table 1
Leake, R., Barnes, D., Pinder, S., Ellis, I., Anderson, L., Anderson, T., Adamson, R., Rhodes, T., Miller, K., & Walker, R. (2000) · Journal of Clinical Pathology · doi:10.1136/jcp.53.8.634 · Cited by 189
Kinetic Studies of Formaldehyde Binding in Tissue
Helander, K. G. (1994) · Biotechnic & Histochemistry · doi:10.3109/10520299409106282 · Cited by 180 · cited 1×
“Although complete tissue fixation requires 24 hours, a minimum of 6 preprocessor hours of formalin fixation is required for consistent IHC assay results.(19,22,23) Nonformalin fixatives and or alternative fixation methodologies are strongly discouraged for several reasons.”
BackgroundShi, S., Liu, C., & Taylor, C. R. (2007) · Journal of Histochemistry & Cytochemistry · doi:10.1369/jhc.6p7080.2006 · Cited by 173 · cited 1×
“Ideally, all IHC assays would be interpreted using a single, universal standardized scoring system.(75) The different cellular and structural antigenic targets, broad spectrum of clinical situations in which IHC is used, and the lack of consistent, reliable, external and internal control standards, makes this an unrea…”
MethodSelf-citationTaylor, C. R., Shi, S., Chen, C., Young, L. L., Yang, C. J., & Côté, R. J. (1996) · Biotechnic & Histochemistry · doi:10.3109/10520299609117171 · Cited by 146 · cited 1×
“The method of applying the energy (pressure cooker, microwave, waterbath) is substantially less important than the amount of energy applied to the slides by the AR system.(56) AR energy above this threshold generally does not improve antigen detection.”
MethodSelf-citationHuman papillomavirus in a necessary cause of invasive cervical cancer worldwide
(1999) · Pure Amsterdam UMC · doi:10.1002/(sici)1096-9896(199909)189:1 · Cited by 140
NCCN Task Force Report: Adjuvant Therapy for Breast Cancer
Carlson, R. W., Brown, E., Burstein, H. J., Gradishar, W. J., Hudis, C. A., Loprinzi, C. L., Mamounas, E. P., Perez, E. A., Pritchard, K. I., Ravdin, P. M., et al. (2006) · Journal of the National Comprehensive Cancer Network · doi:10.6004/jnccn.2006.2001 · Cited by 140 · cited 1×
“These recommendations are in step with the NCCLS (CLSI) guidelines for HER2 IHC assays that the type of fixative and length of fixation be included in the pathology report.(41,42) Insufficient, inconsistent, and different types of fixation and tissue processing are the key factors behind suboptimal and inconsistent IH…”
MethodEstrogen Receptor Analysis for Breast Cancer
Diaz, L. K., & Sneige, N. (2005) · Advances in Anatomic Pathology · doi:10.1097/00125480-200501000-00003 · Cited by 127
Diagnostic Immunohistochemistry: What can Go Wrong?
Yaziji, H., & Barry, T. S. (2006) · Advances in Anatomic Pathology · doi:10.1097/01.pap.0000213041.39070.2f · Cited by 106 · cited 1×
“The expression levels of some antigens can vary between neoplasms from different patients, between benign and malignant tissues, and between different types of neoplasms.(53) Three examples of this issue are provided: Example 1: the level of CD117 (C-Kit) expressed in gastrointestinal stromal tumors (GISTs) from diffe…”
BackgroundSelf-citationMarzo, A. M. D., Fedor, H. L., Gage, W. R., & Rubin, M. A. (2002) · Human Pathology · doi:10.1053/hupa.2002.126187 · Cited by 104 · cited 1×
“In general, underfixation is a substantially larger problem than overfixation.(43,44) This recommendation plays a key role in standardizing fixation parameters for IHC assays.”
BackgroundMicrowave fixation: Understanding the variables to achieve rapid reproducible results
Giberson, R. T., & Demaree, R. S. (1995) · Microscopy Research and Technique · doi:10.1002/jemt.1070320307 · Cited by 78
Ogawa, Y., Moriya, T., Kato, Y., Oguma, M., Ikeda, K., Takashima, T., Nakata, B., Ishikawa, T., & Hirakawa, K. (2004) · Breast Cancer · doi:10.1007/bf02984548 · Cited by 76
Effect of Heat-Induced Antigen Retrieval Following Inconsistent Formalin Fixation
Boenisch, T. (2005) · Applied immunohistochemistry & molecular morphology · doi:10.1097/01.0000146524.74402.a4 · Cited by 71 · cited 1×
“For most contemporary oncologic antigens, a minimum threshold level amount of energy must be applied via AR procedure to all types of tissue specimens, regardless of the length of time above 6 hours the tissue specimen has been fixed.(54,55) The method of applying the energy (pressure cooker, microwave, waterbath) is…”
MethodBiomarkers for prediction of sensitivity to EGFR inhibitors in non-small cell lung cancer
Hirsch, F. R., & Witta, S. (2005) · Current Opinion in Oncology · doi:10.1097/01.cco.0000155059.39733.9d · Cited by 68
Bunn, P. A., Dziadziuszko, R., Varella‐Garcia, M., Franklin, W. A., Witta, S. E., Kelly, K. L., & Hirsch, F. R. (2006) · Clinical Cancer Research · doi:10.1158/1078-0432.ccr-06-0261 · Cited by 68
Dziadziuszko, R., Hirsch, F. R., Varella‐Garcia, M., & Bunn, P. A. (2006) · Clinical Cancer Research · doi:10.1158/1078-0432.ccr-06-0087 · Cited by 64
Antigen Retrieval Immunohistochemistry and Molecular Morphology in the Year 2001
Shi, S., Côté, R. J., & Taylor, C. R. (2001) · Applied immunohistochemistry & molecular morphology · doi:10.1097/00129039-200106000-00002 · Cited by 61
Self-citationAntibodies Immunoreactive With Formalin-Fixed Tissue Antigens Recognize Linear Protein Epitopes
Sompuram, S. R., Vani, K., Hafer, L. J., & Bogen, S. A. (2005) · American Journal of Clinical Pathology · doi:10.1309/6h0arqf7k3y608eh · Cited by 59
Standardization in immunohistochemistry: the role of antigen retrieval in molecular morphology
Taylor, C. R. (2006) · Biotechnic & Histochemistry · doi:10.1080/10520290600667866 · Cited by 58
Self-citationTaylor, C. R. (2006) · Applied immunohistochemistry & molecular morphology · doi:10.1097/00129039-200609000-00001 · Cited by 56 · cited 1×
“The different cellular and structural antigenic targets, broad spectrum of clinical situations in which IHC is used, and the lack of consistent, reliable, external and internal control standards, makes this an unrealistic goal.(95,96) Many oncologic-related nuclear regulator antigens are normally present in the nucleu…”
BackgroundSelf-citationParaffin section immunocytochemistry for estrogen receptor: The time has come
Taylor, C. R. (1996) · Cancer · doi:10.1002/(sici)1097-0142(19960615)77:12<2419::aid-cncr1>3.0.co;2-h · Cited by 48
Self-citationEmerson, L. L., Tripp, S. R., Baird, B. C., Layfield, L. J., & Rohr, L. R. (2005) · American Journal of Clinical Pathology · doi:10.1309/gn6qcbmlleatlk2m · Cited by 47
Lee, H., Douglas-Jones, A. G., Morgan, J. M., & Jasani, B. (2002) · Journal of Clinical Pathology · doi:10.1136/jcp.55.3.236 · Cited by 41 · cited 1×
“Predictive IHC assays are strongly influenced by factors such as length of formalin fixation.(22,81) Genetically engineered, rabbit monoclonal antibodies, such as clone SP1 ER antibody (Lab Vision Co, Fremont, CA) have greater avidity compared with mouse monoclonal antibodies.”
BackgroundPang, Y., von Turkovich, M., Wu, H., Mitchell, J. M., Mount, S. L., Taatjes, D. J., & Cooper, K. (2006) · American Journal of Clinical Pathology · doi:10.1309/ebcb6h54k1n2p9ql · Cited by 30
Leong, A. S. ‐., & Price, D. (2004) · Pathology · doi:10.1080/00313020410001721564 · Cited by 27
Immunohistochemical detection of p53--effect of fixation and methods of antigen retrieval.
Bassarova, A. V., & Popov, A. A. (1998) · PubMed · Cited by 16
Boenisch, T. (2004) · Applied immunohistochemistry & molecular morphology · doi:10.1097/00129039-200406000-00013 · Cited by 8 · cited 1×
“AR energy above this threshold generally does not improve antigen detection.(57) Poor or inconsistently optimized AR relative to tissue fixation is responsible for most suboptimal contemporary automated IHC assay results.”
BackgroundGoldstein, N. S., & Bosler, D. S. (2007) · American Journal of Clinical Pathology · doi:10.1309/athvf5r4cqukb7lx · Cited by 6 · cited 1×
“Interpreting IHC assays in small specimens differs from their interpretation in large specimens.(94) In small specimens, the extent and intensity of immunoreactivity should be assessed in the regional area with the highest proportion of target immunoreactivity.”
BackgroundSelf-citation
Cited by
Use of Archived Specimens in Evaluation of Prognostic and Predictive Biomarkers
Simon, R. M., Paik, S., & Hayes, D. F. (2009) · JNCI Journal of the National Cancer Institute · doi:10.1093/jnci/djp335 · Cited by 1,037
Fedchenko, N., & Reifenrath, J. (2014) · Diagnostic Pathology · doi:10.1186/s13000-014-0221-9 · Cited by 808
Bordeaux, J., Welsh, A. W., Agarwal, S., Killiam, E., Baquero, M. T., Hanna, J. A., Anagnostou, V. K., & Rimm, D. L. (2010) · BioTechniques · doi:10.2144/000113382 · Cited by 589
Ramos-Vara, J. A., & Miller, M. A. (2014) · Veterinary Pathology · doi:10.1177/0300985813505879 · Cited by 437
Taube, J. M., Akturk, G., Angelo, M., Engle, E. L., Gnjatic, S., Greenbaum, S., Greenwald, N. F., Hedvat, C. V., Hollmann, T. J., Juco, J., et al. (2020) · Journal for ImmunoTherapy of Cancer · doi:10.1136/jitc-2019-000155 · Cited by 283
Metadata
- Authors
- Goldstein, N. S., Hewitt, S. M., Taylor, C. R., Yaziji, H., & Hicks, D. G.
- Venue
- Applied Immunohistochemistry & Molecular Morphology
- Published
- 2007-06
- Volume
- 15
- Issue
- 2
- Pages
- 124-133
- ISSN
- 1533-4058 (ISSN-L)
- 1541-2016
- OpenAlex
- W2001430684
- Cited by
- 220
- References
- 45
- FWCI
- 11.27
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.