Diagnostic Efficiency in Digital Pathology: A Comparison of Optical Versus Digital Assessment in 510 Surgical Pathology Cases
The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
Prior work has shown that digital images and microscopic slides can be interpreted with comparable diagnostic accuracy. Although accuracy has been well-validated, the interpretative time for digital images has scarcely been studied and concerns about efficiency remain a major barrier to adoption. We investigated the efficiency of digital pathology when compared with glass slide interpretation in the diagnosis of surgical pathology biopsy and resection specimens. Slides were pulled from 510 surgical pathology cases from 5 organ systems (gastrointestinal, gynecologic, liver, bladder, and brain). Original diagnoses were independently confirmed by 2 validating pathologists. Diagnostic slides were scanned using the Philips IntelliSite Pathology Solution. Each case was assessed independently on digital and optical by 3 reading pathologists, with a ≥6 week washout period between modalities. Reading pathologists recorded assessment times for each modality; digital times included time to load the case. Diagnostic accuracy was determined based on whether a rendered diagnosis differed significantly from the original diagnosis. Statistical analysis was performed to assess for differences in interpretative times across modalities. All 3 reading pathologists showed comparable diagnostic accuracy across optical and digital modalities (mean major discordance rates with original diagnosis: 4.8% vs. 4.4%, respectively). Mean assessment times ranged from 1.2 to 9.1 seconds slower on digital versus optical. The slowest reader showed a significant learning effect during the course of the study so that digital assessment times decreased over time and were comparable with optical times by the end of the series. Organ site and specimen type did not significantly influence differences in interpretative times. In summary, digital image reading times compare favorably relative to glass slides across a variety of organ systems and specimen types. Mean increase in assessment time is 4 seconds/case. This time can be minimized with experience and may be further balanced by the improved ease of electronic chart access allowed by digital slide viewing, as well as quantitative assessments which can be expedited on digital images.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Whole slide images for primary diagnostics in dermatopathology: A feasibility study
Al-Janabi, S., Huisman, A., Vink, A., Leguit, R. J., Offerhaus, G. J. A., ten Kate, F. J. W., van Dijk, M. R., & van Diest, P. J. (2012) · Journal of Clinical Pathology · doi:10.1136/jclinpath-2011-200277 · Cited by 81
Cited by
Steiner, D. F., MacDonald, R., Liu, Y., Truszkowski, P., Hipp, J. D., Gammage, C., Thng, F., Peng, L., & Stumpe, M. C. (2018) · American Journal of Surgical Pathology · doi:10.1097/pas.0000000000001151 · Cited by 489
“2 The faster review in the second session was not associated with any signi fi cant differences in accuracy between sessions, either overall or as a function of assistance modality.”
BackgroundMukhopadhyay, S., Feldman, M. D., Abels, E., Ashfaq, R., Beltaifa, S., Cacciabeve, N. G., Cathro, H. P., Cheng, L., Cooper, K., Dickey, G. E., et al. (2018) · American Journal of Surgical Pathology · doi:10.1097/pas.0000000000000948 · Cited by 399
Self-citationDigital Pathology: Advantages, Limitations and Emerging Perspectives
Jahn, S. W., Plass, M., & Moinfar, F. (2020) · Journal of Clinical Medicine · doi:10.3390/jcm9113697 · Cited by 348
Artificial intelligence in digital breast pathology: Techniques and applications
Ibrahim, A., Gamble, P., Jaroensri, R., Abdelsamea, M. M., Mermel, C. H., Chen, P.-H. C., & Rakha, E. A. (2020) · The Breast · doi:10.1016/j.breast.2019.12.007 · Cited by 202
“A similar study conducted by Mills et al. assessed diagnostic ef fi ciency on 510 surgical pathology cases and found a median increase in diagnostic time of 4 s per case for digital reads compared to glass [16].”
MethodGreenhalgh, T., Maylor, H., Shaw, S., Wherton, J., Papoutsi, C., Betton, V., Nelissen, N., Gremyr, A., Rushforth, A., Koshkouei, M., et al. (2020) · JMIR Research Protocols · doi:10.2196/16861 · Cited by 152
“Research suggests that substantial improvements in service efficiency and safety can occur [44,45], and it is hoped the change will help address a serious and worsening workforce crisis in pathology [46].”
Background
Metadata
- Authors
- Mills, A. M., Gradecki, S. E., Horton, B. J., Blackwell, R., Moskaluk, C. A., Mandell, J. W., Mills, S. E., & Cathro, H. P.
- Venue
- American Journal of Surgical Pathology
- Published
- 2018-01
- Volume
- 42
- Issue
- 1
- Pages
- 53-59
- ISSN
- 0147-5185 (ISSN-L)
- OpenAlex
- W2753233764
- Cited by
- 47
- References
- 1
- FWCI
- 2.79
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Diagnostic Efficiency in Digital Pathology: A Comparison of Optical Versus Digital Assessment in 510 Surgical Pathology Cases. https://app.cochat.ai/papers/10.1097/pas.0000000000000930
- The paper
- Mills, A. M., Gradecki, S. E., Horton, B. J., Blackwell, R., Moskaluk, C. A., Mandell, J. W., Mills, S. E., & Cathro, H. P. (2018). Diagnostic Efficiency in Digital Pathology: A Comparison of Optical Versus Digital Assessment in 510 Surgical Pathology Cases. American Journal of Surgical Pathology. https://doi.org/10.1097/pas.0000000000000930
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.