Cited by 112Central Venous Catheters and HemodialysisNosocomial Infections in ICUInfective Endocarditis Diagnosis and Management

The DOI matches its Crossref record.

Risk factors for central line-associated bloodstream infection in a pediatric cardiac intensive care unit

Abstract

Objective To identify risk factors for central line-associated bloodstream infection (BSI) in patients receiving care in a pediatric cardiac intensive care unit. Design Matched case-control study. Setting CICU at Children's Hospital Boston. Patients Central line-associated BSI cases were identified between April 2004 and December 2006. We identified two randomly selected control patients who had a central vascular catheter and were admitted within 7 days of each index case. Measurements and main results Univariate and multivariate conditional logistic regression analyses were used to identify risk factors for central line-associated BSI. In a secondary analysis, risk factors for central line-associated BSI in those cases who underwent cardiac surgery were sought. During the study period, 67 central line-associated BSIs occurred in 61 patients. Independent risk factors for central line-associated BSI were nonelective admission for medical management (odds ratio [OR] = 6.51 [1.58-26.78]), the presence of noncardiac comorbidities (OR = 4.95 [1.49-16.49]), initial absolute neutrophil count or =3 units (OR = 5.56 [1.35-22.87]), central line days > or =7 (OR = 6.06 [1.65-21.83]), and use of hydrocortisone (OR = 28.94 [2.55-330.37]). In those patients who underwent cardiac surgery (n = 37 cases and 108 controls), independent risk factors for central line-associated BSI were admission weight or =15 (OR = 3.44 [1.19-9.92]), blood product exposure > or =3 units (OR = 3.38 [1.28-11.76])…

Overview

Integrity signals

Registry

Crossref · 10.1097/pcc.0b013e318198b19a

Cites

Statistics

Recomputing p-values needs the paper’s full text.

Verification

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Citations

Cites

Still being checked.

Research works printed but not linked: 25

  1. OʼGrady, 2002, Pediatrics, 110, e51, 10.1542/peds.110.5.e51 · DOI
  2. Pittet, 1994, JAMA, 271, 1598, 10.1001/jama.1994.03510440058033 · DOI
  3. Slonim, 2001, Pediatr Crit Care Med, 2, 170, 10.1097/00130478-200104000-00012 · DOI
  4. Yogaraj, 2002, Pediatrics, 110, 481, 10.1542/peds.110.3.481 · DOI
  5. Elward, 2006, Infect Control Hosp Epidemiol, 27, 553, 10.1086/505096 · DOI
  6. Odetola, 2003, Pediatr Crit Care Med, 4, 432, 10.1097/01.PCC.0000090286.24613.40 · DOI
  7. Costello, 2008, Pediatrics, 121, 915, 10.1542/peds.2007-1577 · DOI
  8. Borschel, 2006, Am J Infect Control, 34, 388, 10.1016/j.ajic.2005.08.004 · DOI
  9. Levy, 2003, J Hosp Infect, 53, 111, 10.1053/jhin.2002.1359 · DOI
  10. Couto, 2006, Infect Control Hosp Epidemiol, 27, 571, 10.1086/504931 · DOI
  11. Garcia-San Miguel, 2006, Infect Control Hosp Epidemiol, 27, 576, 10.1086/505094 · DOI
  12. Pawar, 2004, J Cardiothorac Vasc Anesth, 18, 304, 10.1053/j.jvca.2004.03.009 · DOI
  13. Jenkins, 2002, J Thorac Cardiovasc Surg, 124, 97, 10.1067/mtc.2002.122311 · DOI
  14. Garcia-Teresa, 2007, Intensive Care Med, 33, 466, 10.1007/s00134-006-0508-8 · DOI
  15. Mahieu, 2001, J Hosp Infect, 48, 20, 10.1053/jhin.2000.0930 · DOI
  16. Taylor, 2006, Crit Care Med, 34, 2302, 10.1097/01.CCM.0000234034.51040.7F · DOI
  17. Shorr, 2005, Chest, 127, 1722, 10.1378/chest.127.5.1722 · DOI
  18. Banbury, 2006, J Am Coll Surg, 202, 131, 10.1016/j.jamcollsurg.2005.08.028 · DOI
  19. Blajchman, 2002, Am J Ther, 9, 389, 10.1097/00045391-200209000-00005 · DOI
  20. Shorr, 2005, Curr Opin Crit Care, 11, 468, 10.1097/01.ccx.0000176689.18433.f4 · DOI
  21. Millar, 2007, Pediatr Cardiol, 28, 176, 10.1007/s00246-006-0053-9 · DOI
  22. Zimmerman, 2002, Crit Care Med, 30, 1178, 10.1097/00003246-200205000-00048 · DOI
  23. Massin, 2007, Acta Paediatr, 96, 753, 10.1111/j.1651-2227.2007.00275.x · DOI
  24. Pollack, 1996, Crit Care Med, 24, 743, 10.1097/00003246-199605000-00004 · DOI
  25. Wernovsky, 1995, Circulation, 92, 2226, 10.1161/01.CIR.92.8.2226 · DOI · Paper page

Cited by

Sorted by citations

See all 112

Metadata

Authors
Costello, J. M., Graham, D. A., Morrow, D. F., Potter-Bynoe, G., Sandora, T. J., & Laussen, P. C.
Affiliations
Boston Children's Hospital (US)
Venue
Pediatric Critical Care Medicine
Published
2009-07
Volume
10
Issue
4
Pages
453-459
ISSN
1529-7535 (ISSN-L)
OpenAlex
W1996570654
Cited by
112
References
0
Citations by year
2026: 1 · 2024: 6 · 2023: 7 · 2022: 5 · 2021: 8 · 2020: 8 · 2019: 5 · 2018: 6 · 2017: 10 · 2016: 7 · 2015: 4 · 2014: 8 · 2013: 10 · 2012: 12
FWCI
12.23
Type
journal article
Language
en
Open access
closed
Locations
  • Pediatric Critical Care Medicine (publishedVersion)
  • PubMed (publishedVersion)
Topics
  • Health Sciences › Medicine › Critical Care and Intensive Care Medicine › Central Venous Catheters and Hemodialysis
  • Health Sciences › Medicine › Critical Care and Intensive Care Medicine › Nosocomial Infections in ICU
  • Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Infective Endocarditis Diagnosis and Management
Keywords
central line-associated bloodstream infection, pediatric cardiac intensive care, risk factors, central venous catheters, cardiac surgery, cortisol, blood product exposure, mechanical ventilation, neutropenia, device-related infection, pediatric congenital heart disease, nosocomial infection prevention, catheter dwell time
MeSH terms
Catheterization, Central Venous, Cross Infection, Female, Heart Defects, Congenital, Heart Diseases, Cardiac Surgical Procedures, Humans, Infant, Infant, Newborn, Male, Risk Factors, Time Factors, Intensive Care Units, Pediatric, Comorbidity, Case-Control Studies, Bacteremia, Catheter-Related Infections

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Risk factors for central line-associated bloodstream infection in a pediatric cardiac intensive care unit. https://app.cochat.ai/papers/10.1097/pcc.0b013e318198b19a
The paper
Costello, J. M., Graham, D. A., Morrow, D. F., Potter-Bynoe, G., Sandora, T. J., & Laussen, P. C. (2009). Risk factors for central line-associated bloodstream infection in a pediatric cardiac intensive care unit. Pediatric Critical Care Medicine. https://doi.org/10.1097/pcc.0b013e318198b19a