The ReWalk Powered Exoskeleton to Restore Ambulatory Function to Individuals with Thoracic-Level Motor-Complete Spinal Cord Injury
The DOI matches its Crossref record; 13 of the 14 references it cites were found in a registry or an index.
Abstract
OBJECTIVE: The aim of this study was to assess the safety and performance of ReWalk in enabling people with paraplegia due to spinal cord injury to carry out routine ambulatory functions. DESIGN: This was an open, noncomparative, nonrandomized study of the safety and performance of the ReWalk powered exoskeleton. All 12 subjects have completed the active intervention; three remain in long-term follow-up. RESULTS: After training, all subjects were able to independently transfer and walk, without human assistance while using the ReWalk, for at least 50 to 100 m continuously, for a period of at least 5 to 10 mins continuously and with velocities ranging from 0.03 to 0.45 m/sec (mean, 0.25 m/sec). Excluding two subjects with considerably reduced walking abilities, average distances and velocities improved significantly. Some subjects reported improvements in pain, bowel and bladder function, and spasticity during the trial. All subjects had strong positive comments regarding the emotional/psychosocial benefits of the use of ReWalk. CONCLUSIONS: ReWalk holds considerable potential as a safe ambulatory powered orthosis for motor-complete thoracic-level spinal cord injury patients. Most subjects achieved a level of walking proficiency close to that needed for limited community ambulation. A high degree of performance variability was observed across individuals. Some of this variability was explained by level of injury, but other factors have not been completely identified. Further development and application of this rehabilitation tool to other diagnoses are expected in the future.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“With a built-in multisensor system, an exoskeleton can acquire wearer's motion intensions and accordingly assist the wearer's motion.”
From Recent developments and challenges of lower extremity exoskeletons (2016) · cites this paper as [15]
In the citing paper
“These results also indicate that the patients experienced a reduction in secondary complications resulting from life in a wheelchair such as depression and neuropathic pain.”
From Recent developments and challenges of lower extremity exoskeletons (2016) · cites this paper as [15]
In the citing paper
“Assistance from exoskeletons enable these patients to regain the ability to stand up, sit down, and walk, just as an able-bodied person [14], [15].”
From Recent developments and challenges of lower extremity exoskeletons (2016) · cites this paper as [15]
In the citing paper
“Based on clinical study results of the ReWalk exoskeleton [15], [34], paralyzed patients can practically stand upright and walk with increased independence and their life quality is greatly improved.”
From Recent developments and challenges of lower extremity exoskeletons (2016) · cites this paper as [15]
Citations
Cites
Schulz, R., & Decker, S. (1985) · Journal of Personality and Social Psychology · doi:10.1037//0022-3514.48.5.1162 · Cited by 541
Exercise Recommendations for Individuals with Spinal Cord Injury
Jacobs, P. L., & Nash, M. S. (2004) · Sports Medicine · doi:10.2165/00007256-200434110-00003 · Cited by 453 · cited 8×
“Exercise has been shown to be an effective contributor to overall health, bone density, a proper level of muscle tone, cardiovascular fitness, regular bowel and bladder function, reduced risk for obesity, heart disease, and reduction in type II diabetes for patients with SCI.(28,29) Therapeutic exercise for individual…”
BackgroundInfluentialCorrelates of life satisfaction among persons with spinal cord injury
Dijkers, M. P. J. M. (1999) · Archives of Physical Medicine and Rehabilitation · doi:10.1016/s0003-9993(99)90076-x · Cited by 289
Physical Activity Levels Are Low in Free‐Living Adults with Chronic Paraplegia
Buchholz, A. C., McGillivray, C. F., & Pencharz, P. B. (2003) · Obesity Research · doi:10.1038/oby.2003.79 · Cited by 220
Shoulder pain in persons with thoracic spinal cord injury: Prevalence and characteristics
Alm, M., Saraste, H., & Norrbrink, C. (2008) · Journal of Rehabilitation Medicine · doi:10.2340/16501977-0173 · Cited by 179 · cited 1×
“Upper body exercises including hand ergometry or weight lifting may increase the likelihood of overuse of already taxed upper limb joints, particularly for thoraciclevel injured individuals who rely on wheelchair propulsion for locomotion and their arms for transfers.(16,38,39) Having an SCI results in a 40% reduction…”
BackgroundPain and life quality within 2 years of spinal cord injury
Anke, A., Stenehjem, A. E., & Stanghelle, J. K. (1995) · Spinal Cord · doi:10.1038/sc.1995.120 · Cited by 138
Levins, S. M., Redenbach, D., & Dyck, I. (2004) · Physical Therapy · doi:10.1093/ptj/84.6.496 · Cited by 133 · cited 1×
“training during acute rehabilitation, decreased access to exercise facilities and adequate adaptive fitness equipment, limited time, and psychologic factors.(31) The physical deconditioning resulting from largely sedentary lives of individuals with thoracic or higher level SCI is well documented.”
BackgroundThrasher, T. A., Graham, G. M., & Popović, M. R. (2005) · Artificial Organs · doi:10.1111/j.1525-1594.2005.29076.x · Cited by 106
Wheelchair accessibility of public buildings: a review of the literature
Welage, N., & Liu, K. P. Y. (2010) · Disability and Rehabilitation Assistive Technology · doi:10.3109/17483107.2010.522680 · Cited by 63 · cited 1×
“However, because of significant architectural and environmental restrictions, there are limitations associated with wheelchair use.(11) Furthermore, the typical seated wheelchair posture does not load the legs in a normal manner(12) and can lead to pressure sores(13,14) and promote joint contractures.”
BackgroundNeuromusculoskeletal Syndromes in Wheelchair Athletes
Groah, S. L., & Lanig, I. S. (2000) · Seminars in Neurology · doi:10.1055/s-2000-9829 · Cited by 32
Cited by
Items 201–300 of 957
A novel gait-based synthesis procedure for the design of 4-bar exoskeleton with natural trajectories
Singh, R., Chaudhary, H., & Singh, A. K. (2017) · Journal of Orthopaedic Translation · doi:10.1016/j.jot.2017.09.001 · Cited by 34
“Various portable rehabilitation devices have been developed, for example, eLEGS [10], compact portable KneeeAnkleeFoot robot [4], and ReWalk [11].”
MethodExoskeletons for Mobility after Spinal Cord Injury: A Personalized Embodied Approach
Forte, G., Leemhuis, E., Favieri, F., Casagrande, M., Giannini, A. M., Gennaro, L. D., & Pazzaglia, M. (2022) · Journal of Personalized Medicine · doi:10.3390/jpm12030380 · Cited by 34
“More evidence suggests a significant improvement in spasticity scores on the modified Ashworth scale directly after an exoskeleton session [9,23] in all muscle groups [11] but not in all patients [25].”
BackgroundInfluentialA Survey on Robotic Prosthetics: Neuroprosthetics, Soft Actuators, and Control Strategies
Jyothish, K. J., & Mishra, S. (2024) · ACM Computing Surveys · doi:10.1145/3648355 · Cited by 37
“Robots are becoming more and more mainstream when it comes to rehabilitation [29], mobility assistance [50], and even in the area of personal telepresence related to clinical care [182].”
BackgroundTsai, C., Delgado, A. D., Weinrauch, W. J., Manente, N., Levy, I., Escalon, M. X., Bryce, T. N., & Spungen, A. M. (2019) · Archives of Physical Medicine and Rehabilitation · doi:10.1016/j.apmr.2019.11.010 · Cited by 35
Johns, J. S., Krogh, K., Rodriguez, G. M., Eng, J. J., Haller, E., Heinen, M., Laredo, R., Longo, W. E., Montero-Colon, W., Wilson, C. S., et al. (2021) · Journal of Spinal Cord Medicine · doi:10.1080/10790268.2021.1883385 · Cited by 37
Zhang, B., Wang, S., Zhou, M., & Xu, W. (2021) · Robotics and Autonomous Systems · doi:10.1016/j.robot.2021.103842 · Cited by 38
From a biological template model to gait assistance with an exosuit
Firouzi, V., Davoodi, A., Bahrami, F., & Sharbafi, M. A. (2021) · Bioinspiration & Biomimetics · doi:10.1088/1748-3190/ac2e0d · Cited by 35
Gait robot-assisted rehabilitation in persons with spinal cord injury: A scoping review
Stampacchia, G., Gazzotti, V., Olivieri, M., Andrenelli, E., Bonaiuti, D., Calabrò, R. S., Carmignano, S. M., Cassio, A., Fundarò, C., Companini, I., et al. (2022) · Neurorehabilitation · doi:10.3233/nre-220061 · Cited by 40
Ekelem, A., & Goldfarb, M. T. (2018) · Frontiers in Neuroscience · doi:10.3389/fnins.2018.00374 · Cited by 32
“…generally called hybrid FES systems, which can provide several advantages relative to using FES alone (Andrews et al., 1988; Isakov et al., 1992; Goldfarb et al., 2003; Bulea et al., 2013; del-Ama et al., 2014; Chang et al., 2017; Anaya et al., 2018), and one prior study investigated a hybrid…”
BackgroundCharette, C., Déry, J., Blanchette, A. K., Faure, C., Routhier, F., Bouyer, L. J., & Lamontagne, M. (2023) · Clinical Rehabilitation · doi:10.1177/02692155231164092 · Cited by 38
“Wearable powered exoskeletons represent a promising rehabilitation tool for standing and locomotor training that may complement conventional locomotor training after a spinal cord injury by enabling more repetition and intensive exercise.(5,6) Systematic reviews have shown functional and health benefits associated wit…”
BackgroundZhang, X., Rong, X., & Luo, H. (2024) · Frontiers in Rehabilitation Sciences · doi:10.3389/fresc.2024.1246773 · Cited by 42
Developing a Mobile Lower Limb Robotic Exoskeleton for Gait Rehabilitation
Guo, Z., Yu, H., & Yin, Y. H. (2014) · Journal of Medical Devices · doi:10.1115/1.4026900 · Cited by 35
“In recent years, several systems, such as eLEGS [4], Rewark [5], and Indego [6], have been developed for independent walking.”
MethodNalam, V., & Lee, H. (2019) · IEEE/ASME Transactions on Mechatronics · doi:10.1109/tmech.2019.2892472 · Cited by 31
Pasinetti, S., Fornaser, A., Lancini, M., Cecco, M. D., & Sansoni, G. (2019) · IEEE Sensors Journal · doi:10.1109/jsen.2019.2957667 · Cited by 35
“To overcome such limitations, in recent years, novel active orthosis (often called exoskeletons) have been developed [1]–[3].”
BackgroundOkawara, H., Sawada, T., Matsubayashi, K., Sugai, K., Tsuji, O., Nagoshi, N., Matsumoto, M., & Nakamura, M. (2019) · Spinal Cord · doi:10.1038/s41393-019-0403-0 · Cited by 31
Learning Gait Models With Varying Walking Speeds
Zou, C., Huang, R., Cheng, H., & Qiu, J. (2020) · IEEE Robotics and Automation Letters · doi:10.1109/lra.2020.3006818 · Cited by 31
“Significant achievements have been made in last decades, such as Lokomat [1], ReWalk [2], EKSO GT [3], Indego [4] and HAL [5].”
MethodGait Phases Blended Control for Enhancing Transparency on Lower-Limb Exoskeletons
Camardella, C., Porcini, F., Filippeschi, A., Marcheschi, S., Solazzi, M., & Frisoli, A. (2021) · IEEE Robotics and Automation Letters · doi:10.1109/lra.2021.3075368 · Cited by 31
“A limitation of this study is that the Blend control was tested on a single device and it could output different results with different exoskeletons, although many other HKA or THKA lowerlimb exoskeletons in literature share the same kinematics [1], [17], [29], [30].”
ResultChen, S., Wang, Z., Li, Y., Tang, J., Wang, X., Huang, L., Fang, Z.-W., Xu, T., Xu, J., Guo, F., et al. (2022) · Frontiers in Neurorobotics · doi:10.3389/fnbot.2022.848443 · Cited by 32
“Most experiments involved 60–120min of training per session, three times a week (Esquenazi et al., 2012; Zeilig et al., 2012; Fineberg et al., 2013; Kolakowsky-Hayner, 2013; Kressler et al., 2014; Benson et al., 2015; Hartigan et al., 2015; Kozlowski et al., 2015; Yang et al., 2015).”
BackgroundMethodLeg Force Control Through Biarticular Muscles for Human Walking Assistance
Sharbafi, M. A., Barazesh, H., Iranikhah, M., & Andre Seyfarth, A. (2018) · Frontiers in Neurorobotics · doi:10.3389/fnbot.2018.00039 · Cited by 31
Zhao, D., Yang, J., Okoye, M. O., & Wang, S. (2019) · IEEE Access · doi:10.1109/access.2019.2922258 · Cited by 33
“The typical exoskeleton robots include: exoskeleton system ‘‘Ekso’’ developed by UC Berkeley [5], ‘‘HAL’’ developed by University of Tsukuba in Japan [6], ‘‘ReWalk’’ developed by ReWalk Robotics in Israel [7], ‘‘ALEX’’ developed by University of Delaware in USA [8], and ‘‘Power assisting suit’’ in Kanagawa Institute o…”
Mohamad, H., & Ozgoli, S. (2022) · Robotics and Autonomous Systems · doi:10.1016/j.robot.2022.104319 · Cited by 31
Wang, Y., Li, Z., Wang, X., Yu, H., Liao, W., & Arifoğlu, D. (2021) · Machines · doi:10.3390/machines9120367 · Cited by 33
Hasan, S., & Dhingra, A. K. (2022) · Results in Control and Optimization · doi:10.1016/j.rico.2022.100123 · Cited by 33
Increasing Payload Capacity of Wearable Robots Using Linear Actuators
Choo, J., & Park, J. H. (2017) · IEEE/ASME Transactions on Mechatronics · doi:10.1109/tmech.2017.2705091 · Cited by 32
Jansen, O., Schildhauer, T. A., Meindl, R. C., Tegenthoff, M., Schwenkreis, P., Sczesny-Kaiser, M., Grasmücke, D., Fisahn, C., & Aach, M. (2017) · Global Spine Journal · doi:10.1177/2192568217713754 · Cited by 34
“Posture-controlled devices facilitate locomotion training regardless of remaining motor function, but their primary application would be to complete SCI cases with no residual EMG signals.(22,42) The HAL Robot Suit featuring its cutaneous EMG electrodes for each separate and side-independent muscle group requires the…”
BackgroundCumplido, C., Rueda, F. M., Puyuelo, G., Plaza, A., Hernández-Melero, M., Barquín-Santos, E., Destarac, M. A., & García, E. (2023) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/s12984-023-01161-4 · Cited by 31
Wearable rehabilitation exoskeletons of the lower limb: analysis of versatility and adaptability
Plaza, A., Hernández, M., Puyuelo, G., Garces, E., & García, E. (2020) · Disability and Rehabilitation Assistive Technology · doi:10.1080/17483107.2020.1858976 · Cited by 34
Linnenberg, C., & Weidner, R. (2022) · Applied Ergonomics · doi:10.1016/j.apergo.2022.103706 · Cited by 37
van Nes, I. J. W., van Dijsseldonk, R. B., van Herpen, F. H. M., Rijken, H., Geurts, A. C. H., & Keijsers, N. (2022) · Journal of Spinal Cord Medicine · doi:10.1080/10790268.2022.2052502 · Cited by 34
“In contrast to previous studies assessing the health effects of exoskeleton training, 4,16,17,20 we included a homogeneous group of 21 people with chronic complete SCI.”
BackgroundResultInfluentialAsselin, P. K., Cirnigliaro, C. M., Kornfeld, S. D., Knezevic, S., Lackow, R. M., Elliott, M., Bauman, W. A., & Spungen, A. M. (2020) · Archives of Physical Medicine and Rehabilitation · doi:10.1016/j.apmr.2020.07.018 · Cited by 28
Evaluation of a lower-extremity robotic exoskeleton for people with knee osteoarthritis
McGibbon, C. A., Sexton, A., Jayaraman, A., Deems-Dluhy, S., Fabara, E. E., Adans-Dester, C. P., Bonato, P., Marquis, F., Turmel, S., & Belzile, É. L. (2021) · Assistive Technology · doi:10.1080/10400435.2021.1887400 · Cited by 33
“stroke and spinal cord injury survivors) (Esquenazi et al., 2012; Hartigan et al., 2015; Kolakowsky-Hayner et al., 2013); these solutions are not suitable for those with KOA, the majority of whom are ambulatory and can walk faster than these devices allow (Gok et al.”
BackgroundVoluntary Assist-as-Needed Controller for an Ankle Power-Assist Rehabilitation Robot
Yang, R., Shen, Z., Lyu, Y., Zhuang, Y., Li, L., & Song, R. (2022) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2022.3228070 · Cited by 32
“of rehabilitation robots have been designed, such as 7-DOF CAREX for upper limb rehabilitation [5], Rutgers for hand rehabilitation [6], ReWalk for lower limbs rehabilitation [7], Robot-assisted AFO for ankle rehabilitation [8], etc.”
MethodNepomuceno, P., Silva, W. S., Pakosh, M. T., Musselman, K. E., & Craven, B. C. (2024) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/s12984-024-01365-2 · Cited by 37
Chen, W., Zhang, B., Tan, X., Zhao, Y., Liu, L., & Zhao, X. (2024) · IEEE Transactions on Robotics · doi:10.1109/tro.2024.3502226 · Cited by 34
Fuzzy Sliding Mode Control for Dynamic Walking Assistance in Lower Limb Exoskeletons
Gebrecherkos, T. H., Berhe, A. G., Gurusamy, S., & Abdissa, C. M. (2025) · IEEE Access · doi:10.1109/access.2025.3607679 · Cited by 29
Gait patterns generation based on basis functions interpolation for the TWIN lower-limb exoskeleton
Vassallo, C., Giuseppe, S. D., Piezzo, C., Maludrottu, S., Cerruti, G., D’Angelo, M. L., Gruppioni, E., Marchese, C., Castellano, S., Guanziroli, E., et al. (2020) · Proceedings - IEEE International Conference on Robotics and Automation/Proceedings · doi:10.1109/icra40945.2020.9197250 · Cited by 29
Effect of using of a lower-extremity exoskeleton on disability of people with multiple sclerosis
McGibbon, C. A., Sexton, A., Gryfe, P., Dutta, T., Jayaraman, A., Deems-Dluhy, S., Novak, A. C., Fabara, E. E., Adans-Dester, C. P., & Bonato, P. (2021) · Disability and Rehabilitation Assistive Technology · doi:10.1080/17483107.2021.1874064 · Cited by 27
Han, J. I., Lee, J.-H., Choi, H. S., Kim, J., & Choi, J. (2022) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2022.3196468 · Cited by 31
“Specifically, lower limb exoskeleton robots provide stability and support during gait cycles [3] and are widely used in the field of rehabilitation [4]–[8].”
BackgroundExoskelette in der Rehabilitation Querschnittgelähmter: Möglichkeiten und Grenzen
Aach, M., Meindl, R. C., Geßmann, J., Schildhauer, T. A., Citak, M., & Cruciger, O. (2015) · Der Unfallchirurg · doi:10.1007/s00113-014-2616-1 · Cited by 30
Håkansson, S., Tuci, M., Bolliger, M., Curt, A. E. P., Jutzeler, C. R., & Brüningk, S. C. (2024) · Experimental Neurology · doi:10.1016/j.expneurol.2024.114913 · Cited by 34
Tahamipour-Z., S. M., Sani, S. K. H., Tootoonchi, M. R. A., Akbarzadeh, A., & Devin, M. G. F. (2020) · Iranian Journal of Science and Technology Transactions of Electrical Engineering · doi:10.1007/s40998-020-00358-w · Cited by 25
Vision-Based Autonomous Walking in a Lower-Limb Powered Exoskeleton
Bao, W., Villarreal, D. J., & Chiao, J. ‐. (2020) · IEEE International Conference on Bioinformatics and Bioengineering (BIBE) · doi:10.1109/bibe50027.2020.00141 · Cited by 30
“For example, lower-limb powered exoskeletons such as ReWalk [5], HAL [6], Ekso [7], and Indego [8] are playing an important role in healthcare and rehabilitation.”
BackgroundKim, H. S., Park, J. H., Lee, H. S., Lee, J. Y., Jung, J. W., Park, S.-B., Hyun, D. J., Park, S.-I., Yoon, J., Lim, H., et al. (2021) · Journal of Korean Medical Science · doi:10.3346/jkms.2021.36.e80 · Cited by 27
Liu, J., Zhou, X., He, B., Li, P., Wang, C., & Wu, X. (2022) · IEEE Robotics and Automation Letters · doi:10.1109/lra.2022.3185380 · Cited by 26
“Examples of lower-limb exoskeletons include the ReWalk [2], Ekso [3], and Indego [4].”
BackgroundExoskeletons for lower-limb rehabilitation
Moreno, J. C., Figueiredo, J., & Pons, J. L. (2018) · Elsevier eBooks · doi:10.1016/b978-0-12-811995-2.00008-4 · Cited by 27
García-Vallejo, D., Font-Llagunes, J. M., & Schiehlen, W. (2015) · Nonlinear Dynamics · doi:10.1007/s11071-015-2507-1 · Cited by 26
Liang, F., Mo, L., Sun, Y., Guo, C., Gao, F., Liao, W., Cao, J., Li, B., Song, Z., Wang, D., et al. (2024) · Cyborg and Bionic Systems · doi:10.34133/cbsystems.0122 · Cited by 26
Yatsuya, K., Hirano, S., Saitoh, E., Tanabe, S., Tanaka, H., Eguchi, M., Katoh, M., Shimizu, Y., Uno, A., & Kagaya, H. (2016) · Journal of Spinal Cord Medicine · doi:10.1080/10790268.2016.1226701 · Cited by 24
Postol, N., Marquez, J. L., Spartalis, S., Bivard, A., & Spratt, N. J. (2018) · Disability and Rehabilitation Assistive Technology · doi:10.1080/17483107.2018.1499137 · Cited by 25
“A 2016 feasibility study with spinal cord injured participants in the ReWalk found that users had high expectations of the benefit they may derive from exoskeletal therapy, and these expectations were generally not met [43].”
BackgroundSchrade, S. O., Menner, M., Shirota, C., Winiger, P., Stutz, A., Zeilinger, M. N., Lambercy, O., & Gassert, R. (2020) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2020.3006787 · Cited by 27
“Such devices are available for use in clinics (e.g. Ekso and EksoGT, Ekso Bionics, USA) [4], [5] and also home environments (ReWalk Personal 6.0 and ReWalk Rehabilitation, ReWalk Robotics, USA) [6], [7].”
InfluentialMa, Y., Wu, X., Wang, C., Yi, Z., & Liang, G. (2019) · Sensors · doi:10.3390/s19245449 · Cited by 25
“In past decades, numerous exoskeletons were designed such as the hybrid assistive limb (HAL) [3], EKSO [4], ReWalk [5], Indego [6] and brain-machine-interface (BMI)-controlled rehabilitation exoskeletons [7–9].”
BackgroundMaggio, M. G., Naro, A., Luca, R. D., Latella, D., Balletta, T., Caccamo, L., Pioggia, G., Bruschetta, D., & Calabrò, R. S. (2022) · Journal of Personalized Medicine · doi:10.3390/jpm12040619 · Cited by 26
An event-driven control to achieve adaptive walking assist with gait primitives
Lim, B., Kim, K., Lee, J., Jang, J., & Shim, Y. (2015) · IEEE/RSJ International Conference on Intelligent Robots and Systems (IROS) · doi:10.1109/iros.2015.7354211 · Cited by 25
“On the other hand, actuated wearable devices have been used in limited fields such as rehabilitation in hospitals [1], [2].”
MethodA semi-active hybrid neuroprosthesis for restoring lower limb function in paraplegics
Kirsch, N. A., Alibeji, N. A., Fisher, L. E., Gregory, C. M., & Sharma, N. (2014) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/embc.2014.6944144 · Cited by 25
“Recently, powered orthotic devices, such as the Vanderbilt exoskeleton [8], ReWalk exoskeleton [9], Mina exoskeleton [10], and Ekso Bionics exoskeleton [11] have been developed to enable paraplegics to walk again.”
MethodHayes, S. C., Wilcox, C. R. J., White, H. S. F., & Vanicek, N. (2018) · Journal of Spinal Cord Medicine · doi:10.1080/10790268.2018.1426236 · Cited by 33
Design of Lower-Limb Exoskeletons and Emulator Systems
Witte, K. A., & Collins, S. H. (2019) · Elsevier eBooks · doi:10.1016/b978-0-12-814659-0.00013-8 · Cited by 25
Martínez, A., Durrough, C. M., & Goldfarb, M. T. (2020) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2020.2977339 · Cited by 27
Design and Motion Control of a Lower Limb Robotic Exoskeleton
Önen, Ü., Botsalı, F. M., Kalyoncu, M., Şahin, Y., & Tınkır, M. (2017) · InTech eBooks · doi:10.5772/67458 · Cited by 27
“ReWalk [3, 17] has two different models developed for rehabilitation and life support of SCI patients.”
BackgroundKressler, J., Wymer, T., & Domingo, A. (2017) · Journal of Rehabilitation Medicine · doi:10.2340/16501977-2281 · Cited by 23
“Preliminary evidence has shown several potential health benefits from overground bionic ambulation (OBA) training in which maximal (complete) assistance is provided during walking (1, 2).”
BackgroundChoi, H. S., & Baek, Y. S. (2020) · PLoS ONE · doi:10.1371/journal.pone.0242000 · Cited by 25
An adaptive controller for human lower extremity exoskeleton robot
Hasan, S., & Dhingra, A. K. (2021) · Microsystem Technologies · doi:10.1007/s00542-020-05207-8 · Cited by 26
Postol, N., Spratt, N. J., Bivard, A., & Marquez, J. L. (2021) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/s12984-021-00967-4 · Cited by 28
“Improvements in mood and mental state have also been reported [14].”
BackgroundZhang, P., & Zhang, J. (2022) · Robotica · doi:10.1017/s0263574721001934 · Cited by 24
Uğurlu, B., Oshima, H., & Narikiyo, T. (2014) · Proceedings - IEEE International Conference on Robotics and Automation/Proceedings · doi:10.1109/icra.2014.6907028 · Cited by 26
“Following a similar trend, researchers introduced ReWalk, an electrically-actuated lower body exoskeleton with clinically demonstrated assistive capabilities [4].”
MethodAccelerometry-enabled measurement of walking performance with a robotic exoskeleton: a pilot study
Lonini, L., Shawen, N., Scanlan, K. T., Rymer, W. Z., Kording, K. P., & Jayaraman, A. (2016) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/s12984-016-0142-9 · Cited by 27
“The primary clinical outcome measures currently used to assess functional ambulation with exoskeletons are the 6-Minute-Walk-Test (6MWT) and the Ten-MeterWalk-Test (10mWT) [11, 12].”
BackgroundSadeqi, S., Bourgeois, S. P., Park, E. J., & Arzanpour, S. (2017) · Journal of Rehabilitation and Assistive Technologies Engineering · doi:10.1177/2055668317697596 · Cited by 24
Lower Limb Exoskeleton for Rehabilitation with Improved Postural Equilibrium
Menga, G., & Ghirardi, M. (2018) · Robotics · doi:10.3390/robotics7020028 · Cited by 26
“Similar is REWALK [31], while MINDWALKER [32] tries to capture the user intention by elaborating eye motion.”
Lajeunesse, V., Routhier, F., Vincent, C., Lettre, J., & Michaud, F. (2018) · Technology and Disability · doi:10.3233/tad-180195 · Cited by 25
Hwang, S. H., Sun, D. I., Han, J., & Kim, W. (2021) · Intelligent Service Robotics · doi:10.1007/s11370-020-00346-3 · Cited by 24
Real-Time Stairs Geometric Parameters Estimation for Lower Limb Rehabilitation Exoskeleton
Zhao, X., Chen, W., Yan, X., Wang, J., & Wu, X. (2018) · Chinese Control and Decision Conference (CCDC) · doi:10.1109/ccdc.2018.8408001 · Cited by 23
“A variety of lower limb rehabilitation exoskeletons such as [1–5] have been presented.”
BackgroundTrajectory Generation and Control of a Lower Limb Exoskeleton for Gait Assistance
Luo, L., Foo, M. J., Ramanathan, M., Er, J. K., Chiam, C. H., Li, L., Yau, W., & Ang, W. T. (2022) · Journal of Intelligent & Robotic Systems · doi:10.1007/s10846-022-01763-5 · Cited by 22
Muscle coordination and recruitment during squat assistance using a robotic ankle–foot exoskeleton
Jeong, H., Haghighat, P., Kantharaju, P., Jacobson, M., Jeong, H., & Kim, M. (2023) · Scientific Reports · doi:10.1038/s41598-023-28229-4 · Cited by 27
A walking assistive device with intention detection using back-driven pneumatic artificial muscles
Kanno, T., Morisaki, D., Miyazaki, R., Endo, G., & Kawashima, K. (2015) · International Conference on Rehabilitation Robotics · doi:10.1109/icorr.2015.7281260 · Cited by 25
“ReWalk uses motion sensors which detect the changes in center of gravity.”
BackgroundDynamic Bipedal Walking under Stick-Slip Transitions
Gamus, B., & Or, Y. (2015) · SIAM Journal on Applied Dynamical Systems · doi:10.1137/140956816 · Cited by 25
“Potential applications of autonomous legged robots vary from military and security [62] through search and rescue [42] to education and entertainment [2, 77], rehabilitation assistance [1, 21], and even planetary exploration [44, 84].”
BackgroundThe efficacy of powered orthoses on walking in persons with paraplegia
Arazpour, M., Hutchins, S. W., & Bani, M. A. (2014) · Prosthetics and Orthotics International · doi:10.1177/0309364613520031 · Cited by 23
Development and control of a robotic lower limb exoskeleton for paraplegic patients
Yang, M., Wang, X., Zhu, Z., Xi, R., & Wu, Q. (2018) · Proceedings of the Institution of Mechanical Engineers Part C Journal of Mechanical Engineering Science · doi:10.1177/0954406218761484 · Cited by 25
Unparameterized Optimization of the Spring Characteristic of Parallel Elastic Actuators
van der Spaa, L., Wolfslag, W. J., & Wisse, M. (2019) · IEEE Robotics and Automation Letters · doi:10.1109/lra.2019.2893425 · Cited by 23
“The use of elastic elements in ankle orthoses and prostheses has been extensively studied, both for passive [13], [17] and active [18]–[20] devices.”
BackgroundDesign and Evaluation of a Pediatric Lower-Limb Exoskeleton Joint Actuator
Goo, A. C., Laubscher, C. A., Farris, R. J., & Sawicki, J. T. (2020) · Actuators · doi:10.3390/act9040138 · Cited by 24
“The choice to exclude ankle actuation was made observing that the Indego Therapy exoskeleton [48] and ReWalk exoskeleton [49] have been clinically demonstrated to provide useful gait assistance to individuals with a spinal cord injury without active ankle actuation.”
MethodJatsun, S. F., Савин, С., & Yatsun, A. S. (2016) · International Conference on System Theory, Control and Computing (ICSTCC) · doi:10.1109/icstcc.2016.7790649 · Cited by 22
“It was shown that the use of assistive and medical exoskeletons can bring health benefits and improve the life style of the user [1-4].”
BackgroundAdaptive stair-ascending and stair-descending strategies for powered lower limb exoskeleton
Xu, F., Lin, X., Cheng, H., Huang, R., & Chen, Q. (2017) · IEEE International Conference on Mechatronics and Automation (ICMA) · doi:10.1109/icma.2017.8016052 · Cited by 22
“and interfaces – ReWalk Personal [7], Ekso (Ekso Bionics, US, formerly eLEGs [10]), Rex, HAL (Hybrid Assistive Limb) [5], [6]and AIDER [8], [9] etc.”
BackgroundKeemink, A. Q. L., Brug, T. J. H., van Asseldonk, E. H. F., Wu, A. R., & van der Kooij, H. (2021) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2021.3131366 · Cited by 25
Wang, D., Gu, X., Li, W., Jin, Y., Yang, M., & Yu, H. (2022) · Robotics and Autonomous Systems · doi:10.1016/j.robot.2022.104308 · Cited by 26
Development of Exoskeletons and Applications on Rehabilitation
Guan, X., Ji, L., & Wang, R. (2016) · MATEC Web of Conferences · doi:10.1051/matecconf/20164002004 · Cited by 30
Gasparri, G. M., Bair, M. O., Libby, R. P., & Lerner, Z. F. (2018) · IEEE/RSJ International Conference on Intelligent Robots and Systems (IROS) · doi:10.1109/iros.2018.8593904 · Cited by 23
“Exoskeletons used to treat adults with stroke and spinal cord injury are designed to restore a complete, or near-complete lack of locomotor function, and are therefore typically heavy and are mechanically geared to sacrifice actuator speed for peak torque [1], [20].”
BackgroundMethodGorman, P. H., Forrest, G. F., Asselin, P. K., Scott, W. H., Kornfeld, S. D., Hong, E., & Spungen, A. M. (2021) · Journal of Clinical Medicine · doi:10.3390/jcm10050964 · Cited by 22
“Two powered exoskeleton devices were used in this study, namely, the ReWalkTM (ReWalk Robotics, Marlborough, MA) [22,23] and the Ekso GTTM (Ekso Bionics, Richmond, CA) [24].”
MethodLi, Q., Qi, W., Li, Z., Xia, H., Kang, Y., & Cheng, L. (2022) · IEEE Transactions on Fuzzy Systems · doi:10.1109/tfuzz.2022.3185450 · Cited by 21
“the lower limb exoskeletons have been widely used in human locomotion assistance or augmentation for unimpaired individuals [1]–[3] and clinical mobility therapy for impairment individuals [4], respectively.”
BackgroundData-Driven Modeling for Gait Phase Recognition in a Wearable Exoskeleton Using Estimated Forces
Park, K.-W., Choi, J., & Kong, K. (2023) · IEEE Transactions on Robotics · doi:10.1109/tro.2023.3262108 · Cited by 21
“However, in contrast to the fixed hardware configurations of unmanned systems, the dynamics of a custom-designed exoskeleton was dependent on the human, necessitating the adaptation of control inputs to each user and scenario, resulting in a pattern that is challenging to generalize [20], [21].”
BackgroundBenchmarking lower limb wearable robots: emerging approaches and technologies
Torricelli, D., del‐Ama, A. J., Gonzalez-Vargas, J. E., Moreno, J. C., Gil, Á., & Pons, J. L. (2015) · International Conference on PErvasive Technologies Related to Assistive Environments (PETRA) · doi:10.1145/2769493.2769589 · Cited by 21
“General Terms Measurement, Performance, Reliability, Experimentation, Human Factors, Standardization Keywords Exoskeletons, Benchmarks, Functional evaluation, Rehabilitation, Lower Limb”
Hybrid carbon fiber-textile compliant force sensors for high-load sensing in soft exosuits
Araromi, O. A., Walsh, C. J., & Wood, R. J. (2017) · IEEE/RSJ International Conference on Intelligent Robots and Systems (IROS) · doi:10.1109/iros.2017.8205994 · Cited by 21
“walking patterns in individuals with a walking impairment [4].”
BackgroundLinner, T., Pan, M., Pan, W. L., Taghavi, M., Pan, W., & Bock, T. A. (2018) · International Symposium on Automation and Robotics in Construction (ISARC) · doi:10.22260/isarc2018/0006 · Cited by 22
Boudali, A. M., Sinclair, P. J., & Manchester, I. R. (2019) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2019.2933896 · Cited by 21
“the centre of pressure of the wearer can be used to trigger the switching between different modes [16].”
BackgroundBass, A., Morin, S. N., Vermette, M., Aubertin‐Leheudre, M., & Gagnon, D. H. (2020) · Osteoporosis International · doi:10.1007/s00198-020-05277-4 · Cited by 22
“5 at the hip or femoral neck) have been reported in certain WRE-assisted walking programs—although evidence supporting the use of these values is lacking [17, 18].”
BackgroundStaman, K., Veale, A. J., & van der Kooij, H. (2020) · IEEE Transactions on Medical Robotics and Bionics · doi:10.1109/tmrb.2020.3048224 · Cited by 21
“MANY lower limb, wearable exoskeletons for gait restoration exist, both commercially and for research: [1], [2], [3], [4], [5], [6], [7].”
BackgroundKhamar, M., Edrisi, M., & Forghany, S. (2021) · ISA Transactions · doi:10.1016/j.isatra.2021.08.027 · Cited by 21
A Review on Compliant Joint Mechanisms for Lower Limb Exoskeletons
Gálvez-Zúñiga, M. A., & Aceves-López, A. (2016) · Journal of Robotics · doi:10.1155/2016/5751391 · Cited by 21
“Robots like ReWalk [20], Hal-5 [21], and Ekso [22] belong to this category.”
BackgroundReal-time walking pattern generation for a lower limb exoskeleton, implemented on the Exoped robot
Kazemi, J., & Ozgoli, S. (2019) · Robotics and Autonomous Systems · doi:10.1016/j.robot.2019.02.012 · Cited by 21
“Therefore predefined gait trajectory methods are the usual approach in most of exoskeletons such as ReWalk [7], eLEGS [8] and ATLAS [9], which is aimed at subjects who are losing their ability to move.”
MethodMcGibbon, C. A., Sexton, A., & Gryfe, P. (2024) · Scientific Reports · doi:10.1038/s41598-024-54200-y · Cited by 22
Problems and Experiences on Cable-Based Service Robots for Physiotherapy Applications
Ceccarelli, M. (2013) · Mechanisms and machine science · doi:10.1007/978-3-319-01592-7_3 · Cited by 21
“2012), ReWalk (Esquenazi et al. 2012), MIT exoskeleton (Wehner et al.”
BackgroundOutput feedback assistive control of single-DOF SEA powered exoskeletons
Kardan, I., & Akbarzadeh, A. (2017) · Industrial Robot the international journal of robotics research and application · doi:10.1108/ir-08-2016-0214 · Cited by 19
The History and Future of the WalkON Suit: A Powered Exoskeleton for People With Disabilities
Choi, J., Park, K.-W., Park, J., Lee, D.-H., Song, E., Na, B., Jeon, S. Y., Kim, T. I., Choi, H., Woo, H., et al. (2021) · IEEE Industrial Electronics Magazine · doi:10.1109/mie.2021.3113267 · Cited by 20
Metadata
- Authors
- Esquenazi, A., Talaty, M., Packel, A., & Saulino, M.
- Affiliations
- Moss Rehabilitation Hospital (US)
- Corresponding author
- Esquenazi, Alberto
- Venue
- American Journal of Physical Medicine & Rehabilitation
- Published
- 2012-11
- Volume
- 91
- Issue
- 11
- Pages
- 911-921
- ISSN
- 0894-9115 (ISSN-L)
- OpenAlex
- W2070825536
- Cited by
- 958
- References
- 14
- Citations by year
- 2026: 56 · 2025: 66 · 2024: 89 · 2023: 55 · 2022: 96 · 2021: 100 · 2020: 87 · 2019: 102 · 2018: 79 · 2017: 73 · 2016: 54 · 2015: 55 · 2014: 30 · 2013: 14 · 2012: 1
- FWCI
- 18.22
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- American Journal of Physical Medicine & Rehabilitation (publishedVersion)
- PubMed (publishedVersion)
- Topics
- Physical Sciences › Engineering › Biomedical Engineering › Prosthetics and Rehabilitation Robotics
- Health Sciences › Medicine › Clinical Neurology › Spinal Cord Injury Research
- Health Sciences › Medicine › Rehabilitation › Stroke Rehabilitation and Recovery
- Keywords
- powered exoskeleton, thoracic spinal cord injury, motor complete spinal cord injury, paraplegia, ambulatory function, gait training, walking performance, safety, psychosocial benefits, bowel and bladder function, spasticity, injury level
- MeSH terms
- Adolescent, Adult, Equipment Design, Female, Humans, Locomotion, Male, Middle Aged, Orthotic Devices, Paraplegia, Spinal Cord Injuries, Thoracic Vertebrae, Walking
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.