Student or educator? Sign up with your school email and get 6 months of Pro free.
CoChat

The DOI matches its Crossref record; 24 of the 24 references it cites were found in a registry or an index.

Ear Molding in Newborn Infants with Auricular Deformities

Byrd, H. Steve, Langevin, Claude-Jean, Ghidoni, Lorraine A. · 2010 · Plastic and Reconstructive Surgery

Abstract

BACKGROUND: A review of a single physician's experience in managing over 831 infant ear deformities (488 patients) is presented. METHODS: The authors' methods of molding have advanced from the use of various tapes, glues, and stents, to a comprehensive yet simple system that shapes the antihelix, the triangular fossa, the helical rim, and the overly prominent conchal-mastoid angle (EarWell Infant Ear Correction System). RESULTS: The types of deformities managed, and their relative occurrence, are as follows: (1) prominent/cup ear, 373 ears (45 percent); (2) lidding/lop ear, 224 ears (27 percent); (3) mixed ear deformities, 83 ears (10 percent) (all had associated conchal crus); (4) Stahl's ear, 66 ears (8 percent); (5) helical rim abnormalities, 58 ears (7 percent); (6) conchal crus, 25 ears (3 percent); and (7) cryptotia, two ears (0.2 percent). Bilateral deformities were present in 340 patients (70 percent), with unilateral deformities in 148 patients (30 percent). Fifty-eight infant ears (34 patients) were treated using the final version of the EarWell Infant Ear Correction System with a success rate exceeding 90 percent (good to excellent results). The system was found to be most successful when begun in the first week of the infant's life. When molding was initiated after 3 weeks from birth, only approximately half of the infants had a good response. CONCLUSIONS: Congenital ear deformities are common and only approximately 30 percent self-correct. These deformities can be corrected by initiating appropriate molding in the first week of life. Neonatal molding reduces the need for surgical correction with results that often exceed what can be achieved with the surgical alternative.

Overview

Integrity signals

Registry

Crossref · 10.1097/prs.0b013e3181e617bb

Cites

24 of 24 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Verification

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

26 more claims about this paper

Create a free account to see every claim other papers make about this one.

See all claims — free account

Citations

Cites

Research works printed but not linked: 2

  1. Merlob, 1995, J Perinatol, 15, 293
  2. Tan, 2003, N Z Med J, 116, U584

Cited by

See all 179

Metadata

Authors
Byrd, H. S., Langevin, C.-J., & Ghidoni, L. A.
Affiliations
Children's Medical Center (US)
Venue
Plastic and Reconstructive Surgery
Published
2010-10
Volume
126
Issue
4
Pages
1191-1200
ISSN
0032-1052 (ISSN-L)
OpenAlex
W2030061075
Cited by
178
References
24
Citations by year
2026: 12 · 2025: 17 · 2024: 24 · 2023: 20 · 2022: 19 · 2021: 21 · 2020: 16 · 2019: 10 · 2018: 4 · 2017: 13 · 2016: 4 · 2015: 5 · 2014: 2 · 2013: 4 · 2012: 4
FWCI
3.73
Type
journal article
Language
en
Open access
closed
Locations
  • Plastic & Reconstructive Surgery (publishedVersion)
  • PubMed (publishedVersion)
Topics
  • Health Sciences › Medicine › Surgery › Reconstructive Facial Surgery Techniques
  • Health Sciences › Medicine › Genetics (clinical) › Congenital Ear and Nasal Anomalies
  • Health Sciences › Medicine › Surgery › Craniofacial Disorders and Treatments
Keywords
congenital ear deformity, neonates, lop ear, antihelix
MeSH terms
Congenital Abnormalities, Adhesives, Cosmetic Techniques, Ear, External, Esthetics, Female, Humans, Infant, Newborn, Male, Retrospective Studies, Splints, Cohort Studies, Stents, Treatment Outcome, Plastic Surgery Procedures, Surgical Fixation Devices, Surgical Tape, Ear Auricle

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.