Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 226

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

A Novel Approach to Contrast-Enhanced Breast Magnetic Resonance Imaging for Screening: High-Resolution Ultrafast Dynamic Imaging

Mann, Ritse M., Mus, Roel D., van Zelst, Jan, Geppert, Christian, Karssemeijer, Nico, Platel, Bram·2014·Investigative Radiology

Abstract

OBJECTIVES: The use of breast magnetic resonance imaging (MRI) as screening tool has been stalled by high examination costs. Scan protocols have lengthened to optimize specificity. Modern view-sharing sequences now enable ultrafast dynamic whole-breast MRI, allowing much shorter and more cost-effective procedures. This study evaluates whether dynamic information from ultrafast breast MRI can be used to replace standard dynamic information to preserve accuracy. MATERIALS AND METHODS: We interleaved 20 ultrafast time-resolved angiography with stochastic trajectory (TWIST) acquisitions (0.9 × 1 × 2.5 mm, temporal resolution, 4.3 seconds) during contrast inflow in a regular high-resolution dynamic MRI protocol. A total of 160 consecutive patients with 199 enhancing abnormalities (95 benign and 104 malignant) were included. The maximum slope of the relative enhancement versus time curve (MS) obtained from the TWIST and curve type obtained from the regular dynamic sequence as defined in the breast imaging reporting and data system (BIRADS) lexicon were recorded. Diagnostic performance was compared using receiver operating characteristic analysis. RESULTS: All lesions were visible on both the TWIST and standard series. Maximum slope allows discrimination between benign and malignant disease with high accuracy (area under the curve, 0.829). Types of MS were defined in analogy to BIRADS curve types: MS type 3 implies a high risk of malignancy (MS >13.3%/s; specificity, 85%), MS type 2 yields intermediate risk (MS <13.3%/s and >6.4%/s), and MS type 1 implies a low risk (MS <6.4%/s; sensitivity, 90%). This simplification provides a much higher accuracy than the much lengthier BIRADS curve type analysis does (area under the curve, 0.812 vs 0.692; P = 0.0061). CONCLUSIONS: Ultrafast dynamic breast MRI allows detection of breast lesions and classification with high accuracy using MS. This allows substantial shortening of scan protocols and hence reduces imaging costs, which is beneficial especially for screening.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1097/rli.0000000000000057

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 226

Metadata

Authors
Mann, R. M., Mus, R. D., van Zelst, J., Geppert, C., Karssemeijer, N., & Platel, B.
Venue
Investigative Radiology
Published
2014-09
Volume
49
Issue
9
Pages
579-585
ISSN
0020-9996 (ISSN-L)
OpenAlex
W2007662772
Cited by
226
References
1
FWCI
12.27
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: A Novel Approach to Contrast-Enhanced Breast Magnetic Resonance Imaging for Screening: High-Resolution Ultrafast Dynamic Imaging. https://app.cochat.ai/papers/10.1097/rli.0000000000000057
The paper
Mann, R. M., Mus, R. D., van Zelst, J., Geppert, C., Karssemeijer, N., & Platel, B. (2014). A Novel Approach to Contrast-Enhanced Breast Magnetic Resonance Imaging for Screening: High-Resolution Ultrafast Dynamic Imaging. Investigative Radiology. https://doi.org/10.1097/rli.0000000000000057

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.