Abstract
OBJECTIVES: The use of breast magnetic resonance imaging (MRI) as screening tool has been stalled by high examination costs. Scan protocols have lengthened to optimize specificity. Modern view-sharing sequences now enable ultrafast dynamic whole-breast MRI, allowing much shorter and more cost-effective procedures. This study evaluates whether dynamic information from ultrafast breast MRI can be used to replace standard dynamic information to preserve accuracy. MATERIALS AND METHODS: We interleaved 20 ultrafast time-resolved angiography with stochastic trajectory (TWIST) acquisitions (0.9 × 1 × 2.5 mm, temporal resolution, 4.3 seconds) during contrast inflow in a regular high-resolution dynamic MRI protocol. A total of 160 consecutive patients with 199 enhancing abnormalities (95 benign and 104 malignant) were included. The maximum slope of the relative enhancement versus time curve (MS) obtained from the TWIST and curve type obtained from the regular dynamic sequence as defined in the breast imaging reporting and data system (BIRADS) lexicon were recorded. Diagnostic performance was compared using receiver operating characteristic analysis. RESULTS: All lesions were visible on both the TWIST and standard series. Maximum slope allows discrimination between benign and malignant disease with high accuracy (area under the curve, 0.829). Types of MS were defined in analogy to BIRADS curve types: MS type 3 implies a high risk of malignancy (MS >13.3%/s; specificity, 85%), MS type 2 yields intermediate risk (MS <13.3%/s and >6.4%/s), and MS type 1 implies a low risk (MS <6.4%/s; sensitivity, 90%). This simplification provides a much higher accuracy than the much lengthier BIRADS curve type analysis does (area under the curve, 0.812 vs 0.692; P = 0.0061). CONCLUSIONS: Ultrafast dynamic breast MRI allows detection of breast lesions and classification with high accuracy using MS. This allows substantial shortening of scan protocols and hence reduces imaging costs, which is beneficial especially for screening.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
DeLong, E. R., DeLong, D. M., & Clarke-Pearson, D. L. (1988) · Biometrics · doi:10.2307/2531595 · Cited by 22,649 · cited 2×
“The areas under the curve (Az) were compared using the method of DeLong et al.(33) Calculations were performed in SPSS Mann et al Investigative Radiology & Volume 49, Number 9, September 2014”
MethodAmerican Cancer Society Guidelines for Breast Screening with MRI as an Adjunct to Mammography
Saslow, D., Boetes, C., Burke, W., Harms, S., Leach, M. O., Lehman, C. D., Morris, E., Pisano, E., Schnall, M., Sener, S., et al. (2007) · CA: A Cancer Journal for Clinicians · doi:10.3322/canjclin.57.2.75 · Cited by 2,637 · cited 1×
“only is at approximately 40%, already as high as the positive predictive value for mammographic abnormalities in screening.(18,19) Therefore, there”
BackgroundMagnetic resonance imaging of the breast: Recommendations from the EUSOMA working group
Sardanelli, F., Boetes, C., Borisch, B., Decker, T., Federico, M., Gilbert, F. J., Helbich, T., Heywang-Köbrunner, S. H., Kaiser, W. A., Kerin, M. J., et al. (2010) · European Journal of Cancer · doi:10.1016/j.ejca.2010.02.015 · Cited by 992 · cited 3×
“These are respectively obtained before contrast administration, at the peak of contrast enhancement around 90 seconds after administration, and in the late phase 5 to 7 minutes after contrast administration.(10,11) Structured reporting according to the breast imaging reporting and data system (BIRADS) lexicon, which t…”
MethodResultBreast MRI: guidelines from the European Society of Breast Imaging
Mann, R. M., Kuhl, C. K., Kinkel, K., & Boetes, C. (2008) · European Radiology · doi:10.1007/s00330-008-0863-7 · Cited by 839 · cited 1×
“The protocol is an improvement of earlier published protocols that can be used for acquisition of inflow kinetics.(31,32) Patients were positioned in the prone position with their arms down.”
Self-citationDifferentiation of clinically benign and malignant breast lesions using diffusion‐weighted imaging
Guo, Y., Cai, Y., Cai, Z., Gao, Y., An, N., Ma, L., Mahankali, S., & Gao, J. (2002) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.10140 · Cited by 714
MRI for diagnosis of pure ductal carcinoma in situ: a prospective observational study
Kuhl, C. K., Schrading, S., Bieling, H. B., Wardelmann, E., Leutner, C. C., Koenig, R., Kuhn, W., & Schild, H. H. (2007) · The Lancet · doi:10.1016/s0140-6736(07)61232-x · Cited by 711 · cited 1×
“detection of invasive breast cancer but also in the detection of ductal carcinoma in situ (DCIS), the noninvasive precursor of breast cancer.(1) In meta-analysis, an overall sensitivity of 90% has been reported.”
BackgroundMeta-Analysis of MR Imaging in the Diagnosis of Breast Lesions
Peters, N. H. G. M., Borel Rinkes, I. H. M., Zuithoff, N. P. A., Mali, W. P. T. M., Moons, K. G. M., & Peeters, P. H. M. (2008) · Radiology · doi:10.1148/radiol.2461061298 · Cited by 529 · cited 1×
“In meta-analysis, an overall sensitivity of 90% has been reported.(2) The potential of breast MRI is likely even higher because expert centers world-”
BackgroundDiagnostic Architectural and Dynamic Features at Breast MR Imaging: Multicenter Study
Schnall, M. D., Blume, J., Bluemke, D. A., DeAngelis, G. A., DeBruhl, N., Harms, S., Heywang-Köbrunner, S. H., Hylton, N., Kuhl, C. K., Pisano, E. D., et al. (2006) · Radiology · doi:10.1148/radiol.2381042117 · Cited by 514 · cited 1×
“However, especially for the classification of small mass-like lesions, the typical finding in screening,(21,22) additional dynamic information is important.(5,21,23,24) ORIGINAL ARTICLE”
BackgroundKuhl, C., Weigel, S., Schrading, S., Arand, B., Bieling, H., König, R., Tombach, B., Leutner, C., Rieber-Brambs, A., Nordhoff, D., et al. (2010) · Journal of Clinical Oncology · doi:10.1200/jco.2009.23.0839 · Cited by 501 · cited 1×
“only is at approximately 40%, already as high as the positive predictive value for mammographic abnormalities in screening.(18,19) Therefore, there”
BackgroundThomsen, H. S., Morcos, S. K., Almén, T., Bellin, M.-F., Bertolotto, M., Bongartz, G., Clement, O., Leander, P., Heinz-Peer, G., Reimer, P., et al. (2013) · European Radiology · doi:10.1007/s00330-012-2597-9 · Cited by 441
Cited by
Mann, R. M., Cho, N., & Moy, L. (2019) · Radiology · doi:10.1148/radiol.2019182947 · Cited by 917
Self-citationContrast‐enhanced MRI for breast cancer screening
Mann, R. M., Kuhl, C. K., & Moy, L. (2019) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.26654 · Cited by 356
Self-citationNovel Approaches to Screening for Breast Cancer
Mann, R. M., Hooley, R., Barr, R. G., & Moy, L. (2020) · Radiology · doi:10.1148/radiol.2020200172 · Cited by 167
Self-citationDalmiş, M. U., Gubern-Mérida, A., Vreemann, S., Bult, P., Karssemeijer, N., Mann, R., & Teuwen, J. (2019) · Investigative Radiology · doi:10.1097/rli.0000000000000544 · Cited by 120
Self-citation
Metadata
- Authors
- Mann, R. M., Mus, R. D., van Zelst, J., Geppert, C., Karssemeijer, N., & Platel, B.
- Venue
- Investigative Radiology
- Published
- 2014-09
- Volume
- 49
- Issue
- 9
- Pages
- 579-585
- ISSN
- 0020-9996 (ISSN-L)
- OpenAlex
- W2007662772
- Cited by
- 226
- References
- 34
- FWCI
- 12.27
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.