A Novel Approach to Contrast-Enhanced Breast Magnetic Resonance Imaging for Screening: High-Resolution Ultrafast Dynamic Imaging
The DOI matches its Crossref record; 34 of the 34 references it cites were found in a registry or an index.
Abstract
OBJECTIVES: The use of breast magnetic resonance imaging (MRI) as screening tool has been stalled by high examination costs. Scan protocols have lengthened to optimize specificity. Modern view-sharing sequences now enable ultrafast dynamic whole-breast MRI, allowing much shorter and more cost-effective procedures. This study evaluates whether dynamic information from ultrafast breast MRI can be used to replace standard dynamic information to preserve accuracy. MATERIALS AND METHODS: We interleaved 20 ultrafast time-resolved angiography with stochastic trajectory (TWIST) acquisitions (0.9 × 1 × 2.5 mm, temporal resolution, 4.3 seconds) during contrast inflow in a regular high-resolution dynamic MRI protocol. A total of 160 consecutive patients with 199 enhancing abnormalities (95 benign and 104 malignant) were included. The maximum slope of the relative enhancement versus time curve (MS) obtained from the TWIST and curve type obtained from the regular dynamic sequence as defined in the breast imaging reporting and data system (BIRADS) lexicon were recorded. Diagnostic performance was compared using receiver operating characteristic analysis. RESULTS: All lesions were visible on both the TWIST and standard series. Maximum slope allows discrimination between benign and malignant disease with high accuracy (area under the curve, 0.829). Types of MS were defined in analogy to BIRADS curve types: MS type 3 implies a high risk of malignancy (MS >13.3%/s; specificity, 85%), MS type 2 yields intermediate risk (MS <13.3%/s and >6.4%/s), and MS type 1 implies a low risk (MS <6.4%/s; sensitivity, 90%). This simplification provides a much higher accuracy than the much lengthier BIRADS curve type analysis does (area under the curve, 0.812 vs 0.692; P = 0.0061). CONCLUSIONS: Ultrafast dynamic breast MRI allows detection of breast lesions and classification with high accuracy using MS. This allows substantial shortening of scan protocols and hence reduces imaging costs, which is beneficial especially for screening.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
DeLong, E. R., DeLong, D. M., & Clarke-Pearson, D. L. (1988) · Biometrics · doi:10.2307/2531595 · Cited by 22,649 · cited 2×
“The areas under the curve (Az) were compared using the method of DeLong et al.(33) Calculations were performed in SPSS Mann et al Investigative Radiology & Volume 49, Number 9, September 2014”
MethodAmerican Cancer Society Guidelines for Breast Screening with MRI as an Adjunct to Mammography
Saslow, D., Boetes, C., Burke, W., Harms, S., Leach, M. O., Lehman, C. D., Morris, E., Pisano, E., Schnall, M., Sener, S., et al. (2007) · CA: A Cancer Journal for Clinicians · doi:10.3322/canjclin.57.2.75 · Cited by 2,637 · cited 1×
“only is at approximately 40%, already as high as the positive predictive value for mammographic abnormalities in screening.(18,19) Therefore, there”
BackgroundMagnetic resonance imaging of the breast: Recommendations from the EUSOMA working group
Sardanelli, F., Boetes, C., Borisch, B., Decker, T., Federico, M., Gilbert, F. J., Helbich, T., Heywang-Köbrunner, S. H., Kaiser, W. A., Kerin, M. J., et al. (2010) · European Journal of Cancer · doi:10.1016/j.ejca.2010.02.015 · Cited by 992 · cited 3×
“These are respectively obtained before contrast administration, at the peak of contrast enhancement around 90 seconds after administration, and in the late phase 5 to 7 minutes after contrast administration.(10,11) Structured reporting according to the breast imaging reporting and data system (BIRADS) lexicon, which t…”
MethodResultBreast MRI: guidelines from the European Society of Breast Imaging
Mann, R. M., Kuhl, C. K., Kinkel, K., & Boetes, C. (2008) · European Radiology · doi:10.1007/s00330-008-0863-7 · Cited by 839 · cited 1×
“The protocol is an improvement of earlier published protocols that can be used for acquisition of inflow kinetics.(31,32) Patients were positioned in the prone position with their arms down.”
Self-citationDifferentiation of clinically benign and malignant breast lesions using diffusion‐weighted imaging
Guo, Y., Cai, Y., Cai, Z., Gao, Y., An, N., Ma, L., Mahankali, S., & Gao, J. (2002) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.10140 · Cited by 714
MRI for diagnosis of pure ductal carcinoma in situ: a prospective observational study
Kuhl, C. K., Schrading, S., Bieling, H. B., Wardelmann, E., Leutner, C. C., Koenig, R., Kuhn, W., & Schild, H. H. (2007) · The Lancet · doi:10.1016/s0140-6736(07)61232-x · Cited by 711 · cited 1×
“detection of invasive breast cancer but also in the detection of ductal carcinoma in situ (DCIS), the noninvasive precursor of breast cancer.(1) In meta-analysis, an overall sensitivity of 90% has been reported.”
BackgroundMeta-Analysis of MR Imaging in the Diagnosis of Breast Lesions
Peters, N. H. G. M., Borel Rinkes, I. H. M., Zuithoff, N. P. A., Mali, W. P. T. M., Moons, K. G. M., & Peeters, P. H. M. (2008) · Radiology · doi:10.1148/radiol.2461061298 · Cited by 529 · cited 1×
“In meta-analysis, an overall sensitivity of 90% has been reported.(2) The potential of breast MRI is likely even higher because expert centers world-”
BackgroundDiagnostic Architectural and Dynamic Features at Breast MR Imaging: Multicenter Study
Schnall, M. D., Blume, J., Bluemke, D. A., DeAngelis, G. A., DeBruhl, N., Harms, S., Heywang-Köbrunner, S. H., Hylton, N., Kuhl, C. K., Pisano, E. D., et al. (2006) · Radiology · doi:10.1148/radiol.2381042117 · Cited by 514 · cited 1×
“However, especially for the classification of small mass-like lesions, the typical finding in screening,(21,22) additional dynamic information is important.(5,21,23,24) ORIGINAL ARTICLE”
BackgroundKuhl, C., Weigel, S., Schrading, S., Arand, B., Bieling, H., König, R., Tombach, B., Leutner, C., Rieber-Brambs, A., Nordhoff, D., et al. (2010) · Journal of Clinical Oncology · doi:10.1200/jco.2009.23.0839 · Cited by 501 · cited 1×
“only is at approximately 40%, already as high as the positive predictive value for mammographic abnormalities in screening.(18,19) Therefore, there”
BackgroundThomsen, H. S., Morcos, S. K., Almén, T., Bellin, M.-F., Bertolotto, M., Bongartz, G., Clement, O., Leander, P., Heinz-Peer, G., Reimer, P., et al. (2013) · European Radiology · doi:10.1007/s00330-012-2597-9 · Cited by 441
Boetes, C., Barentsz, J. O., Mus, R. D. M., van der Sluis, R. F., van Erning, L. J. T. O., Hendriks, J. H. C. L., Holland, R., & Ruys, S. H. (1994) · Radiology · doi:10.1148/radiology.193.3.7972823 · Cited by 402 · cited 1×
“They also showed that benign lesions enhance later than malignant ones, which is in line with older studies that used single slice techniques to capture contrast inflow in breast lesions.(53) A further advantage of the TWIST sequence is that, because of the data sharing between successive time points, the sequence pro…”
ResultSelf-citationQuantitative Analysis of Dynamic Gd‐DTPA Enhancement in Breast Tumors Using a Permeability Model
Tofts, P. S., Berkowitz, B., & Schnall, M. D. (1995) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910330416 · Cited by 399 · cited 1×
“Consequently, the curve shape is strongly influenced by early leakage of contrast from the vessels into the extravascular extracellular space, a process that is governed by the transfer constant (or K), which is dependent on the permeability surface area of the vessels in the tumor.(47) Studies that modeled dynamic in…”
BackgroundThe psychological impact of mammographic screening. A systematic review
Brett, J., Bankhead, C., Henderson, B., Watson, E., & Austoker, J. (2005) · Psycho-Oncology · doi:10.1002/pon.904 · Cited by 327 · cited 1×
“The following need to biopsy many benign lesions places a high emotional burden on women screened and adds substantial additional costs to screening.(9,36,43,44) This is the reason that a high-resolution T2 sequence that provides detailed morphological information and may show necrosis and edema in and around breast l…”
BackgroundPharmacokinetic Mapping of the Breast: A New Method for Dynamic MR Mammography
Hoffmann, U., Brix, G., Knopp, M. V., Heβ, T., & Lorenz, W. J. (1995) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910330408 · Cited by 303
Diffusion-weighted Imaging Improves the Diagnostic Accuracy of Conventional 3.0-T Breast MR Imaging
EI Khouli, R. H., Jacobs, M. A., Mezban, S. D., Huang, P., Kamel, I. R., Macura, K. J., & Bluemke, D. A. (2010) · Radiology · doi:10.1148/radiol.10091367 · Cited by 268
In vivo diffusion‐weighted MRI of the breast: Potential for lesion characterization
Sinha, S., Lucas‐Quesada, F. A., Sinha, U., DeBruhl, N., & Bassett, L. W. (2002) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.10116 · Cited by 268
Mammographic, US, and MR Imaging Phenotypes of Familial Breast Cancer
Schrading, S., & Kuhl, C. K. (2008) · Radiology · doi:10.1148/radiol.2461062173 · Cited by 227 · cited 1×
“However, especially for the classification of small mass-like lesions, the typical finding in screening,(21,22) additional dynamic information is important.(5,21,23,24) ORIGINAL ARTICLE”
BackgroundReasons Women at Elevated Risk of Breast Cancer Refuse Breast MR Imaging Screening: ACRIN 6666
Berg, W. A., Blume, J. D., Adams, A., Jong, R. A., Barr, R. G., Lehrer, D. E., Pisano, E. D., Evans, W. P., Mahoney, M. C., Hovanessian‐Larsen, L., et al. (2009) · Radiology · doi:10.1148/radiol.2541090953 · Cited by 218 · cited 1×
“Because patients are required to lie motionless in a narrow tube during the procedure, a substantial shortening of the acquisition time also makes the examination more acceptable to women with slight symptoms of claustrophobia.(37,38) Some drawbacks of breast MRI as a screening tool remain present: (1) the need for IV…”
BackgroundGutierrez, R. L., DeMartini, W. B., Eby, P. R., et al. (2009) · American Journal of Roentgenology · doi:10.2214/ajr.08.1983 · Cited by 187 · cited 1×
“However, especially for the classification of small mass-like lesions, the typical finding in screening,(21,22) additional dynamic information is important.(5,21,23,24) ORIGINAL ARTICLE”
BackgroundDelille, J.-P., Slanetz, P. J., Yeh, E. D., Kopans, D. B., & Garrido, L. (2005) · The Breast Journal · doi:10.1111/j.1075-122x.2005.21499.x · Cited by 165 · cited 1×
“Some drawbacks of breast MRI as a screening tool remain present: (1) the need for IV gadolinium-based contrast administration, which implies the need for placement of an IV cannula; (2) the risks associated with contrast administration, including allergic reactions (usually mild) and (rarely) nephrogenic systemic fibr…”
BackgroundPort, R. E., Knopp, M. V., & Brix, G. (2001) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1137 · Cited by 159 · cited 1×
“Nevertheless, these techniques have so far not surfaced in clinical practice because of the difficulties associated with this modeling, which include the determination of an arterial input function that is often not robust.(52) Moreover, modeling techniques for breast imaging are not commercially available and therefo…”
BackgroundComputed-aided diagnosis (CAD) in the detection of breast cancer
Dromain, C., Boyer, B., Ferré, R., Canale, S., Delaloge, S., & Balleyguier, C. (2012) · European Journal of Radiology · doi:10.1016/j.ejrad.2012.03.005 · Cited by 155 · cited 1×
“Although evaluation of MS can be performed without dedicated software, the use of a dedicated breast MRI workstation is still recommended for image registration, the creation of subtraction series, and simple color-coded overlays.(56) It is already possible to create a colorcoded overlay of MS on several commercially…”
MethodClaustrophobia in MRI: the role of cognitions
Thorpe, S., Salkovskis, P. M., & Dittner, A. J. (2008) · Magnetic Resonance Imaging · doi:10.1016/j.mri.2008.01.022 · Cited by 133 · cited 1×
“Because patients are required to lie motionless in a narrow tube during the procedure, a substantial shortening of the acquisition time also makes the examination more acceptable to women with slight symptoms of claustrophobia.(37,38) Some drawbacks of breast MRI as a screening tool remain present: (1) the need for IV…”
Backgroundfor the UK Magnetic Resonance Imaging in Breast Screening (MARIBS) Study Group, Griebsch, I., Brown, J., Boggis, C. R. M., Dixon, A. K., Dixon, M., Easton, D. F., Eeles, R. A., Evans, D. G., Gilbert, F. J., et al. (2006) · British Journal of Cancer · doi:10.1038/sj.bjc.6603356 · Cited by 128 · cited 7×
“The following need to biopsy many benign lesions places a high emotional burden on women screened and adds substantial additional costs to screening.(9,36,43,44) This is the reason that a high-resolution T2 sequence that provides detailed morphological information and may show necrosis and edema in and around breast l…”
BackgroundInfluentialMoore, S. G., Shenoy, P. J., Fanucchi, L. C., Tumeh, J. W., & Flowers, C. R. (2009) · BMC Health Services Research · doi:10.1186/1472-6963-9-9 · Cited by 113
Cost Effectiveness of Breast Cancer Screening With Contrast-Enhanced MRI in High-Risk Women
Taneja, C., Edelsberg, J., Weycker, D. A., Guo, A. X., Oster, G., & Weinreb, J. C. (2009) · Journal of the American College of Radiology · doi:10.1016/j.jacr.2008.10.003 · Cited by 97 · cited 1×
“The following need to biopsy many benign lesions places a high emotional burden on women screened and adds substantial additional costs to screening.(9,36,43,44) This is the reason that a high-resolution T2 sequence that provides detailed morphological information and may show necrosis and edema in and around breast l…”
BackgroundA feasible high spatiotemporal resolution breast DCE-MRI protocol for clinical settings
Tudorica, L. A., Oh, K. Y., Roy, N., Kettler, M. D., Chen, Y., Hemmingson, S. L., Afzal, A., Grinstead, J. W., Laub, G. A., Li, X., et al. (2012) · Magnetic Resonance Imaging · doi:10.1016/j.mri.2012.04.009 · Cited by 78
Saadatmand, S., Tilanus‐Linthorst, M. M. A., Rutgers, E. J. T., Hoogerbrugge, N., Oosterwijk, J. C., Tollenaar, R. A. �. �., Hooning, M. J., Loo, C. E., Obdeijn, I.-M., Heijnsdijk, E. A. M., et al. (2013) · JNCI Journal of the National Cancer Institute · doi:10.1093/jnci/djt203 · Cited by 73 · cited 1×
“Nevertheless, recent cost-effectiveness evaluations have clearly shown that costs in non-BRCA mutation carriers may exceed $100,000 per life year gained, especially in women younger than 50 years.(7) The need for cost reduction of MRI scanning itself is evident from the fact that costs in MRI screening are most influe…”
BackgroundCost-effectiveness of MRI for breast cancer screening in BRCA1/2 mutation carriers
Pataky, R. E., Armstrong, L., Chia, S., Coldman, A. J., Kim‐Sing, C., McGillivray, B., Scott, J., Wilson, C., & Peacock, S. J. (2013) · BMC Cancer · doi:10.1186/1471-2407-13-339 · Cited by 64 · cited 6×
“Nevertheless, recent cost-effectiveness evaluations have clearly shown that costs in non-BRCA mutation carriers may exceed $100,000 per life year gained, especially in women younger than 50 years.7 The need for cost reduction of MRI scanning itself is evident from the fact that costs in MRI screening are most influenc…”
BackgroundInfluentialVeltman, J., Stoutjesdijk, M. J., Mann, R. M., et al. (2008) · European Radiology · doi:10.1007/s00330-008-0870-8 · Cited by 62 · cited 3×
“These are respectively obtained before contrast administration, at the peak of contrast enhancement around 90 seconds after administration, and in the late phase 5 to 7 minutes after contrast administration.(10,11) Structured reporting according to the breast imaging reporting and data system (BIRADS) lexicon, which t…”
MethodResultSelf-citationPediconi, F., Miglio, E., Telesca, M., Luciani, M. L., Kirchin, M. A., Passariello, R., & Catalano, C. (2011) · Investigative Radiology · doi:10.1097/rli.0b013e318230061c · Cited by 60 · cited 1×
“information that is in small mass lesions of vital importance to differentiate between benign and malignant disease.(45) Nevertheless, T2 and DWI may still provide additional information on top of morphology and MS, although the magnitude is unknown.”
BackgroundSchnur, J. B., Montgomery, G. H., Hallquist, M. N., Goldfarb, A. B., Silverstein, J. H., Weltz, C., Kowalski, A. V., & Bovbjerg, D. H. (2008) · International Journal of Behavioral Medicine · doi:10.1007/bf03003070 · Cited by 54
Kriege, M., Brekelmans, C. T. M., Peterse, H. L., Obdeijn, I. M., Boetes, C., Zonderland, H. M., Muller, S. H., Kok, T., Manoliu, R. A., Besnard, A. P. E., et al. (2006) · Breast Cancer Research and Treatment · doi:10.1007/s10549-006-9341-6 · Cited by 52
Baltzer, P., Dietzel, M., & Kaiser, W. A. (2011) · Journal of Computer Assisted Tomography · doi:10.1097/rct.0b013e31821065c3 · Cited by 41 · cited 1×
“This is the reason that a high-resolution T2 sequence that provides detailed morphological information and may show necrosis and edema in and around breast lesions is added to state-of-the-art breast MRI protocols.(13,14) Furthermore, DWI has also been added because cellular density is generally high in breast cancers…”
Background
Cited by
Mann, R. M., Cho, N., & Moy, L. (2019) · Radiology · doi:10.1148/radiol.2019182947 · Cited by 917
Self-citationContrast‐enhanced MRI for breast cancer screening
Mann, R. M., Kuhl, C. K., & Moy, L. (2019) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.26654 · Cited by 356
Self-citationNovel Approaches to Screening for Breast Cancer
Mann, R. M., Hooley, R., Barr, R. G., & Moy, L. (2020) · Radiology · doi:10.1148/radiol.2020200172 · Cited by 167
Self-citationDalmiş, M. U., Gubern-Mérida, A., Vreemann, S., Bult, P., Karssemeijer, N., Mann, R., & Teuwen, J. (2019) · Investigative Radiology · doi:10.1097/rli.0000000000000544 · Cited by 120
Self-citation
Metadata
- Authors
- Mann, R. M., Mus, R. D., van Zelst, J., Geppert, C., Karssemeijer, N., & Platel, B.
- Venue
- Investigative Radiology
- Published
- 2014-09
- Volume
- 49
- Issue
- 9
- Pages
- 579-585
- ISSN
- 0020-9996 (ISSN-L)
- OpenAlex
- W2007662772
- Cited by
- 226
- References
- 34
- FWCI
- 12.27
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.