Incorporation of Time-of-Flight Information Reduces Metal Artifacts in Simultaneous Positron Emission Tomography/Magnetic Resonance Imaging: A Simulation Study
Open accessThe DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Abstract
OBJECTIVES: This study aimed to describe and evaluate the influence of time-of-flight (TOF) information on metal artifact reduction in positron emission tomography (PET) image quality in clinical simultaneous PET/magnetic resonance (MR) scanning. MATERIALS AND METHODS: A total of 7 patients with various malignant tumors were included and underwent a PET/MR examination after standard PET/computed tomography. Baseline TOF and non-TOF PET images were reconstructed. Next, the TOF and non-TOF PET reconstructions were repeated after the introduction of artificial signal voids in the attenuation map to simulate metal artifacts of various sizes in a range of locations. Three different sizes of signal voids were inserted in the attenuation maps for each location of interest: over the maxilla, humeral head, chest, sternum, thoracic and lumbar spine, as well as the femoral head to replicate clinically relevant metal artifacts. The reconstructed images with the artifacts were then compared with the baseline reconstructed images. The mean percentage error in a region of interest surrounding the simulated artifact was used to compare between TOF and non-TOF images. Further comparison between TOF and non-TOF images was performed using histogram analysis. RESULTS: In all cases, the mean percentage error in a region of interest surrounding the simulated artifact was reduced when TOF information was included in the reconstruction. The inclusion of TOF also changes the distribution of smaller errors away from the origin of the artifact. In some anatomical regions, an increase in the number of small errors was noted with TOF, although the differences with non-TOF were minimal. CONCLUSIONS: Positron emission tomographic imaging benefits from the integration of TOF information in simultaneous PET/MR. The inclusion of TOF information in simultaneous PET/MR imaging reduces errors related to metal artifacts at the site of the artifact.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Focus on time-of-flight PET: the benefits of improved time resolution
Conti, M. (2011) · European Journal of Nuclear Medicine and Molecular Imaging · doi:10.1007/s00259-010-1711-y · Cited by 335
Update on time-of-flight PET imaging
Surti, S. (2015) · Journal of Nuclear Medicine · doi:10.2967/jnumed.114.145029 · Cited by 303
Cited by
Recent developments in time-of-flight PET
Vandenberghe, S., Mikhaylova, E., D’Hoe, E., Mollet, P., & Karp, J. S. (2016) · EJNMMI Physics · doi:10.1186/s40658-016-0138-3 · Cited by 368
Mehranian, A., Arabi, H., & Zaidi, H. (2016) · Medical Physics · doi:10.1118/1.4941014 · Cited by 152
Reduction of 18 F-FDG Dose in Clinical PET/MR Imaging by Using Silicon Photomultiplier Detectors
Sekine, T., Delso, G., Zeimpekis, K. G., de Galiza Barbosa, F., ter Voert, E. E. G. W., Huellner, M., & Veit-Haibach, P. (2018) · Radiology · doi:10.1148/radiol.2017162305 · Cited by 79
“The scan parameters were as follows: 120 kVp; 15–80 mA with automatic dose modulation; rotation time, 0.5 second; helical thickness, 3.75 mm; pitch, 39.37 mm per rotation; matrix size, 512 3 512 pixels; section conflict of interest for those authors who are employees of GE Healthcare.”
BackgroundMethodSelf-citationBoellaard, R., Rausch, I., Beyer, T., Delso, G., Yaqub, M., Quick, H. H., & Sattler, B. (2015) · Medical Physics · doi:10.1118/1.4930962 · Cited by 62
Self-citation
Metadata
- Authors
- Davison, H., ter Voert, E. E. G. W., de Galiza Barbosa, F., Veit-Haibach, P., & Delso, G.
- Venue
- Investigative Radiology
- Published
- 2015-07
- Volume
- 50
- Issue
- 7
- Pages
- 423-429
- ISSN
- 0020-9996 (ISSN-L)
- OpenAlex
- W2323100007
- Cited by
- 41
- References
- 2
- FWCI
- 7.39
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Incorporation of Time-of-Flight Information Reduces Metal Artifacts in Simultaneous Positron Emission Tomography/Magnetic Resonance Imaging: A Simulation Study. https://app.cochat.ai/papers/10.1097/rli.0000000000000146
- The paper
- Davison, H., ter Voert, E. E. G. W., de Galiza Barbosa, F., Veit-Haibach, P., & Delso, G. (2015). Incorporation of Time-of-Flight Information Reduces Metal Artifacts in Simultaneous Positron Emission Tomography/Magnetic Resonance Imaging: A Simulation Study. Investigative Radiology. https://doi.org/10.1097/rli.0000000000000146
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.