Measuring Computed Tomography Scanner Variability of Radiomics Features
Open accessThe DOI matches its Crossref record; 27 of the 27 references it cites were found in a registry or an index.
Abstract
OBJECTIVES: The purpose of this study was to determine the significance of interscanner variability in CT image radiomics studies. MATERIALS AND METHODS: We compared the radiomics features calculated for non-small cell lung cancer (NSCLC) tumors from 20 patients with those calculated for 17 scans of a specially designed radiomics phantom. The phantom comprised 10 cartridges, each filled with different materials to produce a wide range of radiomics feature values. The scans were acquired using General Electric, Philips, Siemens, and Toshiba scanners from 4 medical centers using their routine thoracic imaging protocol. The radiomics feature studied included the mean and standard deviations of the CT numbers as well as textures derived from the neighborhood gray-tone difference matrix. To quantify the significance of the interscanner variability, we introduced the metric feature noise. To look for patterns in the scans, we performed hierarchical clustering for each cartridge. RESULTS: The mean CT numbers for the 17 CT scans of the phantom cartridges spanned from -864 to 652 Hounsfield units compared with a span of -186 to 35 Hounsfield units for the CT scans of the NSCLC tumors, showing that the phantom's dynamic range includes that of the tumors. The interscanner variability of the feature values depended on both the cartridge material and the feature, and the variability was large relative to the interpatient variability in the NSCLC tumors for some features. The feature interscanner noise was greatest for busyness and least for texture strength. Hierarchical clustering produced different clusters of the phantom scans for each cartridge, although there was some consistent clustering by scanner manufacturer. CONCLUSIONS: The variability in the values of radiomics features calculated on CT images from different CT scanners can be comparable to the variability in these features found in CT images of NSCLC tumors. These interscanner differences should be considered, and their effects should be minimized in future radiomics studies.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Radiomics: extracting more information from medical images using advanced feature analysis
Lambin, P., Rios-Velazquez, E., Leijenaar, R., Carvalho, S., van Stiphout, R. G. P. M., Granton, P., Zegers, C. M. L., Gillies, R., Boellard, R., Dekker, A., et al. (2012) · European Journal of Cancer · doi:10.1016/j.ejca.2011.11.036 · Cited by 6,084
Decoding tumour phenotype by noninvasive imaging using a quantitative radiomics approach
Aerts, H. J. W. L., Velazquez, E. R., Leijenaar, R. T. H., Parmar, C., Grossmann, P., Carvalho, S., Bussink, J., Monshouwer, R., Haibe-Kains, B., Rietveld, D., et al. (2014) · Nature Communications · doi:10.1038/ncomms5006 · Cited by 5,132
Radiomics: the process and the challenges
Kumar, V., Gu, Y., Basu, S., Berglund, A., Eschrich, S. A., Schabath, M. B., Forster, K., Aerts, H. J. W. L., Dekker, A., Fenstermacher, D., et al. (2012) · Magnetic Resonance Imaging · doi:10.1016/j.mri.2012.06.010 · Cited by 2,258
Texture analysis using gray level run lengths
Galloway, M. M. (1975) · Computer Graphics and Image Processing · doi:10.1016/s0146-664x(75)80008-6 · Cited by 2,141
Tixier, F., Le Rest, C. C., Hatt, M., Albarghach, N., Pradier, O., Metges, J.-P., Corcos, L., & Visvikis, D. (2011) · Journal of Nuclear Medicine · doi:10.2967/jnumed.110.082404 · Cited by 696
Decoding global gene expression programs in liver cancer by noninvasive imaging
Segal, E., Sirlin, C. B., Ooi, C., Adler, A. S., Gollub, J., Chen, X., Chan, B. K., Matcuk, G. R., Barry, C. T., Chang, H. Y., et al. (2007) · Nature Biotechnology · doi:10.1038/nbt1306 · Cited by 629 · cited 1×
“For example, studies have demonstrated that extracted features can increase the stratification in Kaplan-Meier survival analysis(3,4) and partially reproduce the global gene expression profile.(5) However, to maximize the relevance and effectiveness of radiomics, the quantitative features should be reproducible and ro…”
BackgroundRobust Radiomics Feature Quantification Using Semiautomatic Volumetric Segmentation
Parmar, C., Rios Velazquez, E., Leijenaar, R., Jermoumi, M., Carvalho, S., Mak, R. H., Mitra, S., Shankar, B. U., Kikinis, R., Haibe-Kains, B., et al. (2014) · PLoS ONE · doi:10.1371/journal.pone.0102107 · Cited by 611
Leijenaar, R. T. H., Carvalho, S., Velazquez, E. R., van Elmpt, W. J. C., Parmar, C., Hoekstra, O. S., Hoekstra, C. J., Boellaard, R., Dekker, A. L. A. J., Gillies, R. J., et al. (2013) · Acta Oncologica · doi:10.3109/0284186x.2013.812798 · Cited by 427
Ng, F., Kozarski, R., Ganeshan, B., & Goh, V. (2013) · European Journal of Radiology · doi:10.1016/j.ejrad.2012.10.023 · Cited by 362
ibex: An open infrastructure software platform to facilitate collaborative work in radiomics
Zhang, L., Fried, D. V., Fave, X. J., Hunter, L. A., Yang, J., & Court, L. E. (2015) · Medical Physics · doi:10.1118/1.4908210 · Cited by 316
Self-citationTexture-based classification of atherosclerotic carotid plaques
Christodoulou, C. I., Pattichis, C. S., Pantziaris, M., & Nicolaides, A. (2003) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2003.815066 · Cited by 316
Reproducibility and Prognosis of Quantitative Features Extracted from CT Images
Balagurunathan, Y., Gu, Y., Wang, H., Kumar, V., Grove, O., Hawkins, S., Kim, J., Goldgof, D. B., Hall, L. O., Gatenby, R. A., et al. (2014) · Translational Oncology · doi:10.1593/tlo.13844 · Cited by 306
Fried, D. V., Tucker, S. L., Zhou, S., Liao, Z., Mawlawi, O., Ibbott, G., & Court, L. E. (2014) · International Journal of Radiation Oncology*Biology*Physics · doi:10.1016/j.ijrobp.2014.07.020 · Cited by 213
Self-citationYu, H., Caldwell, C., Mah, K., & Mozeg, D. (2009) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2008.2004425 · Cited by 184
Buckler, A. J., Bresolin, L., Dunnick, N. R., Sullivan, D. C., & For the Group (2011) · Radiology · doi:10.1148/radiol.10100799 · Cited by 175
The biology underlying molecular imaging in oncology: from genome to anatome and back again
Gillies, R. J., Anderson, A. R., Gatenby, R. A., & Morse, D. L. (2010) · Clinical Radiology · doi:10.1016/j.crad.2010.04.005 · Cited by 171
Ganeshan, B., Miles, K. A., Young, R. C. D., & Chatwin, C. R. (2008) · European Journal of Radiology · doi:10.1016/j.ejrad.2007.12.005 · Cited by 160
Radiomics in PET: principles and applications
Cook, G., Siddique, M. M., Taylor, B. P., Yip, C., Chicklore, S., & Goh, V. (2014) · Clinical and Translational Imaging · doi:10.1007/s40336-014-0064-0 · Cited by 144
Self-citationComputer‐aided diagnosis: Automatic detection of malignant masses in digitized mammograms
Méndez, A. J., Tahoces, P. G., Lado, M. J., Souto, M., & Vidal, J. J. (1998) · Medical Physics · doi:10.1118/1.598274 · Cited by 138
Hunter, L. A., Krafft, S., Stingo, F., Choi, H., Martel, M. K., Kry, S. F., & Court, L. E. (2013) · Medical Physics · doi:10.1118/1.4829514 · Cited by 117
Self-citationGaneshan, B., Miles, K. A., Young, R. C. D., & Chatwin, C. R. (2007) · Clinical Radiology · doi:10.1016/j.crad.2007.03.004 · Cited by 87
The Quantitative Imaging Network: NCI's Historical Perspective and Planned Goals
Clarke, L. P., Nordstrom, R. J., Zhang, H., Tandon, P., Zhang, Y., Redmond, G., Farahani, K., Kelloff, G., Henderson, L., Shankar, L., et al. (2014) · Translational Oncology · doi:10.1593/tlo.13832 · Cited by 86
Measurements of heterogeneity in gliomas on computed tomography relationship to tumour grade
Skogen, K., Ganeshan, B., Good, C. D., Critchley, G. R., & Miles, K. A. (2012) · Journal of Neuro-Oncology · doi:10.1007/s11060-012-1010-5 · Cited by 85
Computerized analysis of lesions in US images of the breast
Giger, M. L., Al‐Hallaq, H., Huo, Z., Moran, C. J., Wolverton, D., Chan, C. W., & Zhong, W. (1999) · Academic Radiology · doi:10.1016/s1076-6332(99)80115-9 · Cited by 69
Ammonia as a case study for the spontaneous ionization of a simple hydrogen-bonded compound
Palasyuk, T., Troyan, I., Eremets, M., Drozd, V., Medvedev, S., Zaleski–Ejgierd, P., Magos–Palasyuk, E., Wang, H., Bonev, S. A., Dudenko, D., et al. (2014) · Nature Communications · doi:10.1038/ncomms4460 · Cited by 58
Quantitative Computed Tomography Imaging Biomarkers in the Diagnosis and Management of Lung Cancer
Kim, H., Park, C. M., Goo, J. M., Wildberger, J. E., & Kauczor, H. (2015) · Investigative Radiology · doi:10.1097/rli.0000000000000152 · Cited by 51
Xu, J., Fuld, M. K., Fung, G. S. K., & Tsui, B. M. W. (2015) · Physics in Medicine and Biology · doi:10.1088/0031-9155/60/7/2881 · Cited by 16
Cited by
Radiomics: the bridge between medical imaging and personalized medicine
Lambin, P., Leijenaar, R. T. H., Deist, T. M., Peerlings, J., de Jong, E. E. C., van Timmeren, J., Sanduleanu, S., Larue, R. T. H. M., Even, A. J. G., Jochems, A., et al. (2017) · Nature Reviews Clinical Oncology · doi:10.1038/nrclinonc.2017.141 · Cited by 5,688
“The determination of inter-scanner and inter-vendor variability of features is important in radi-omics 23 .”
Radiomics: the facts and the challenges of image analysis
Rizzo, S., Botta, F., Raimondi, S., Origgi, D., Fanciullo, C., Morganti, A. G., & Bellomi, M. (2018) · European Radiology Experimental · doi:10.1186/s41747-018-0068-z · Cited by 1,054
Repeatability and Reproducibility of Radiomic Features: A Systematic Review
Traverso, A., Wee, L., Dekker, A., & Gillies, R. (2018) · International Journal of Radiation Oncology*Biology*Physics · doi:10.1016/j.ijrobp.2018.05.053 · Cited by 903
CT Texture Analysis: Definitions, Applications, Biologic Correlates, and Challenges
Lubner, M. G., Smith, A. D., Sandrasegaran, K., Sahani, D. V., & Pickhardt, P. J. (2017) · RadioGraphics · doi:10.1148/rg.2017170056 · Cited by 773
Limkin, E. J., Sun, R., Dercle, L., Zacharaki, E. I., Robert, C., Reuzé, S., Schernberg, A., Paragios, N., Deutsch, E., & Ferté, C. (2017) · Annals of Oncology · doi:10.1093/annonc/mdx034 · Cited by 757
Metadata
- Authors
- Mackin, D., Fave, X., Zhang, L., Fried, D., Yang, J., Taylor, B., Rodriguez-Rivera, E., Dodge, C., Jones, A. K., & Court, L.
- Venue
- Investigative Radiology
- Published
- 2015-11
- Volume
- 50
- Issue
- 11
- Pages
- 757-765
- ISSN
- 0020-9996 (ISSN-L)
- OpenAlex
- W2398056625
- Cited by
- 651
- References
- 27
- FWCI
- 28.33
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.