Measuring Computed Tomography Scanner Variability of Radiomics Features
Open accessThe DOI matches its Crossref record; 27 of the 27 references it cites were found in a registry or an index.
Abstract
OBJECTIVES: The purpose of this study was to determine the significance of interscanner variability in CT image radiomics studies. MATERIALS AND METHODS: We compared the radiomics features calculated for non-small cell lung cancer (NSCLC) tumors from 20 patients with those calculated for 17 scans of a specially designed radiomics phantom. The phantom comprised 10 cartridges, each filled with different materials to produce a wide range of radiomics feature values. The scans were acquired using General Electric, Philips, Siemens, and Toshiba scanners from 4 medical centers using their routine thoracic imaging protocol. The radiomics feature studied included the mean and standard deviations of the CT numbers as well as textures derived from the neighborhood gray-tone difference matrix. To quantify the significance of the interscanner variability, we introduced the metric feature noise. To look for patterns in the scans, we performed hierarchical clustering for each cartridge. RESULTS: The mean CT numbers for the 17 CT scans of the phantom cartridges spanned from -864 to 652 Hounsfield units compared with a span of -186 to 35 Hounsfield units for the CT scans of the NSCLC tumors, showing that the phantom's dynamic range includes that of the tumors. The interscanner variability of the feature values depended on both the cartridge material and the feature, and the variability was large relative to the interpatient variability in the NSCLC tumors for some features. The feature interscanner noise was greatest for busyness and least for texture strength. Hierarchical clustering produced different clusters of the phantom scans for each cartridge, although there was some consistent clustering by scanner manufacturer. CONCLUSIONS: The variability in the values of radiomics features calculated on CT images from different CT scanners can be comparable to the variability in these features found in CT images of NSCLC tumors. These interscanner differences should be considered, and their effects should be minimized in future radiomics studies.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Radiomics: extracting more information from medical images using advanced feature analysis
Lambin, P., Rios-Velazquez, E., Leijenaar, R., Carvalho, S., van Stiphout, R. G. P. M., Granton, P., Zegers, C. M. L., Gillies, R., Boellard, R., Dekker, A., et al. (2012) · European Journal of Cancer · doi:10.1016/j.ejca.2011.11.036 · Cited by 6,084
Decoding tumour phenotype by noninvasive imaging using a quantitative radiomics approach
Aerts, H. J. W. L., Velazquez, E. R., Leijenaar, R. T. H., Parmar, C., Grossmann, P., Carvalho, S., Bussink, J., Monshouwer, R., Haibe-Kains, B., Rietveld, D., et al. (2014) · Nature Communications · doi:10.1038/ncomms5006 · Cited by 5,132
Radiomics: the process and the challenges
Kumar, V., Gu, Y., Basu, S., Berglund, A., Eschrich, S. A., Schabath, M. B., Forster, K., Aerts, H. J. W. L., Dekker, A., Fenstermacher, D., et al. (2012) · Magnetic Resonance Imaging · doi:10.1016/j.mri.2012.06.010 · Cited by 2,258
Texture analysis using gray level run lengths
Galloway, M. M. (1975) · Computer Graphics and Image Processing · doi:10.1016/s0146-664x(75)80008-6 · Cited by 2,141
Tixier, F., Le Rest, C. C., Hatt, M., Albarghach, N., Pradier, O., Metges, J.-P., Corcos, L., & Visvikis, D. (2011) · Journal of Nuclear Medicine · doi:10.2967/jnumed.110.082404 · Cited by 696
Decoding global gene expression programs in liver cancer by noninvasive imaging
Segal, E., Sirlin, C. B., Ooi, C., Adler, A. S., Gollub, J., Chen, X., Chan, B. K., Matcuk, G. R., Barry, C. T., Chang, H. Y., et al. (2007) · Nature Biotechnology · doi:10.1038/nbt1306 · Cited by 629 · cited 1×
“For example, studies have demonstrated that extracted features can increase the stratification in Kaplan-Meier survival analysis(3,4) and partially reproduce the global gene expression profile.(5) However, to maximize the relevance and effectiveness of radiomics, the quantitative features should be reproducible and ro…”
BackgroundRobust Radiomics Feature Quantification Using Semiautomatic Volumetric Segmentation
Parmar, C., Rios Velazquez, E., Leijenaar, R., Jermoumi, M., Carvalho, S., Mak, R. H., Mitra, S., Shankar, B. U., Kikinis, R., Haibe-Kains, B., et al. (2014) · PLoS ONE · doi:10.1371/journal.pone.0102107 · Cited by 611
Leijenaar, R. T. H., Carvalho, S., Velazquez, E. R., van Elmpt, W. J. C., Parmar, C., Hoekstra, O. S., Hoekstra, C. J., Boellaard, R., Dekker, A. L. A. J., Gillies, R. J., et al. (2013) · Acta Oncologica · doi:10.3109/0284186x.2013.812798 · Cited by 427
Ng, F., Kozarski, R., Ganeshan, B., & Goh, V. (2013) · European Journal of Radiology · doi:10.1016/j.ejrad.2012.10.023 · Cited by 362
ibex: An open infrastructure software platform to facilitate collaborative work in radiomics
Zhang, L., Fried, D. V., Fave, X. J., Hunter, L. A., Yang, J., & Court, L. E. (2015) · Medical Physics · doi:10.1118/1.4908210 · Cited by 316
Self-citation
Cited by
Radiomics: the bridge between medical imaging and personalized medicine
Lambin, P., Leijenaar, R. T. H., Deist, T. M., Peerlings, J., de Jong, E. E. C., van Timmeren, J., Sanduleanu, S., Larue, R. T. H. M., Even, A. J. G., Jochems, A., et al. (2017) · Nature Reviews Clinical Oncology · doi:10.1038/nrclinonc.2017.141 · Cited by 5,688
“The determination of inter-scanner and inter-vendor variability of features is important in radi-omics 23 .”
Radiomics: the facts and the challenges of image analysis
Rizzo, S., Botta, F., Raimondi, S., Origgi, D., Fanciullo, C., Morganti, A. G., & Bellomi, M. (2018) · European Radiology Experimental · doi:10.1186/s41747-018-0068-z · Cited by 1,054
Repeatability and Reproducibility of Radiomic Features: A Systematic Review
Traverso, A., Wee, L., Dekker, A., & Gillies, R. (2018) · International Journal of Radiation Oncology*Biology*Physics · doi:10.1016/j.ijrobp.2018.05.053 · Cited by 903
CT Texture Analysis: Definitions, Applications, Biologic Correlates, and Challenges
Lubner, M. G., Smith, A. D., Sandrasegaran, K., Sahani, D. V., & Pickhardt, P. J. (2017) · RadioGraphics · doi:10.1148/rg.2017170056 · Cited by 773
Limkin, E. J., Sun, R., Dercle, L., Zacharaki, E. I., Robert, C., Reuzé, S., Schernberg, A., Paragios, N., Deutsch, E., & Ferté, C. (2017) · Annals of Oncology · doi:10.1093/annonc/mdx034 · Cited by 757
Deep Learning Predicts Lung Cancer Treatment Response from Serial Medical Imaging
Xu, Y., Hosny, A., Zeleznik, R., Parmar, C., Coroller, T., Franco, I., Mak, R. H., & Aerts, H. J. W. L. (2019) · Clinical Cancer Research · doi:10.1158/1078-0432.ccr-18-2495 · Cited by 628
Berenguer, R., Pastor-Juan, M. D. R., Canales-Vázquez, J., Castro-García, M., Villas, M. V., Mansilla Legorburo, F., & Sabater, S. (2018) · Radiology · doi:10.1148/radiol.2018172361 · Cited by 622
Machine and deep learning methods for radiomics
Avanzo, M., Wei, L., Stancanello, J., Vallières, M., Rao, A., Morin, O., Mattonen, S. A., & El Naqa, I. (2020) · Medical Physics · doi:10.1002/mp.13678 · Cited by 605
Intrinsic dependencies of CT radiomic features on voxel size and number of gray levels
Shafiq‐ul‐Hassan, M., Zhang, G. G., Latifi, K., Ullah, G., Hunt, D. C., Balagurunathan, Y., Abdalah, M. A., Schabath, M. B., Goldgof, D. G., Mackin, D., et al. (2017) · Medical Physics · doi:10.1002/mp.12123 · Cited by 585
Self-citationBeyond imaging: The promise of radiomics
Avanzo, M., Stancanello, J., & El Naqa, I. (2017) · Physica Medica · doi:10.1016/j.ejmp.2017.05.071 · Cited by 483
Validation of A Method to Compensate Multicenter Effects Affecting CT Radiomics
Orlhac, F., Frouin, F., Nioche, C., Ayache, N., & Buvat, I. (2019) · Radiology · doi:10.1148/radiol.2019182023 · Cited by 411
Radiomic Machine-Learning Classifiers for Prognostic Biomarkers of Head and Neck Cancer
Parmar, C., Grossmann, P., Rietveld, D., Rietbergen, M. M., Lambin, P., & Aerts, H. J. W. L. (2015) · Frontiers in Oncology · doi:10.3389/fonc.2015.00272 · Cited by 407
Park, J. E., Park, S. Y., Kim, H. J., & Kim, H. S. (2019) · Korean Journal of Radiology · doi:10.3348/kjr.2018.0070 · Cited by 388
Exploratory Study to Identify Radiomics Classifiers for Lung Cancer Histology
Wu, W., Parmar, C., Grossmann, P., Quackenbush, J., Lambin, P., Bussink, J., Mak, R., & Aerts, H. J. W. L. (2016) · Frontiers in Oncology · doi:10.3389/fonc.2016.00071 · Cited by 378
Deep learning with convolutional neural network in radiology
Yasaka, K., Akai, H., Kunimatsu, A., Kiryu, S., & Abe, O. (2018) · Japanese Journal of Radiology · doi:10.1007/s11604-018-0726-3 · Cited by 368
Larue, R. T. H. M., Defraene, G., De Ruysscher, D., Lambin, P., & van Elmpt, W. (2017) · The British Journal of Radiology · doi:10.1259/bjr.20160665 · Cited by 363
Horvat, N., Veeraraghavan, H., Khan, M., Blazic, I., Zheng, J., Capanu, M., Sala, E., Garcia-Aguilar, J., Gollub, M. J., & Petkovska, I. (2018) · Radiology · doi:10.1148/radiol.2018172300 · Cited by 355
Delta-radiomics features for the prediction of patient outcomes in non–small cell lung cancer
Fave, X., Zhang, L., Yang, J., Mackin, D., Balter, P., Gomez, D., Followill, D., Jones, A. K., Stingo, F., Liao, Z., et al. (2017) · Scientific Reports · doi:10.1038/s41598-017-00665-z · Cited by 353
Self-citationA review in radiomics: Making personalized medicine a reality via routine imaging
Guiot, J., Vaidyanathan, A., Deprez, L., Zerka, F., Danthine, D., Frix, A., Lambin, P., Bottari, F., Tsoutzidis, N., Miraglio, B., et al. (2022) · Medicinal Research Reviews · doi:10.1002/med.21846 · Cited by 337
Radiogenomics: bridging imaging and genomics
Bodalal, Z., Trebeschi, S., Nguyen-Kim, T. D. L., Schats, W., & Beets-Tan, R. (2019) · Abdominal Radiology · doi:10.1007/s00261-019-02028-w · Cited by 310
Choe, J., Lee, S. M., Do, K.-H., Lee, G., Lee, J.-G., Lee, S. M., & Seo, J. B. (2019) · Radiology · doi:10.1148/radiol.2019181960 · Cited by 296
Ibrahim, A., Primakov, S., Beuque, M., Woodruff, H. C., Halilaj, I., Wu, G., Refaee, T., Granzier, R., Widaatalla, Y., Hustinx, R., et al. (2021) · Methods · doi:10.1016/j.ymeth.2020.05.022 · Cited by 265
Larue, R. T. H. M., van Timmeren, J. E., de Jong, E. E. C., Feliciani, G., Leijenaar, R. T. H., Schreurs, W. M. J., Sosef, M. N., Raat, F. H. P. J., van der Zande, F. H. R., Das, M., et al. (2017) · Acta Oncologica · doi:10.1080/0284186x.2017.1351624 · Cited by 262
Meyer, M., Ronald, J., Vernuccio, F., Nelson, R. C., Ramirez-Giraldo, J. C., Solomon, J., Patel, B. N., Samei, E., & Marin, D. (2019) · Radiology · doi:10.1148/radiol.2019190928 · Cited by 258
He, L., Huang, Y., Ma, Z., Liang, C., Liang, C., & Liu, Z. (2016) · Scientific Reports · doi:10.1038/srep34921 · Cited by 256
Image-Based Cardiac Diagnosis With Machine Learning: A Review
Martin-Isla, C., Campello, V. M., Izquierdo, C., Raisi-Estabragh, Z., Baeßler, B., Petersen, S. E., & Lekadir, K. (2020) · Frontiers in Cardiovascular Medicine · doi:10.3389/fcvm.2020.00001 · Cited by 248
Radiomic machine-learning classifiers for prognostic biomarkers of advanced nasopharyngeal carcinoma
Zhang, B., He, X., Ouyang, F., Gu, D., Dong, Y., Zhang, L., Mo, X., Huang, W., Tian, J., & Zhang, S. (2017) · Cancer Letters · doi:10.1016/j.canlet.2017.06.004 · Cited by 246
Self-citationTexture Analysis of Imaging: What Radiologists Need to Know
Varghese, B. A., Cen, S. Y., Hwang, D. H., & Duddalwar, V. A. (2019) · American Journal of Roentgenology · doi:10.2214/ajr.18.20624 · Cited by 243
“The interscanner variability of CT in radiomic metrics implies that the quality and repeatability of radiomic studies depends strongly on the consistency of image acquisition and reconstruction [45].”
BackgroundMethodInfluentialAssessing robustness of radiomic features by image perturbation
Zwanenburg, A., Leger, S., Agolli, L., Pilz, K., Troost, E. G. C., Richter, C., & Löck, S. (2019) · Scientific Reports · doi:10.1038/s41598-018-36938-4 · Cited by 242
“Dene a geometric structure element that includes all voxels within Manhattan distance 1 (i.e. a centre voxel and its directly adjacent neighbours). We used the scipy.ndimage.generate binary structure(3,1) function. 4. Initialise a place-holder for an adapted mask R p with volume V p by copying the original ROI and its…”
MethodKolossváry, M., Karády, J., Szilveszter, B., Kitslaar, P., Hoffmann, U., Merkely, B., & Maurovich-Horvat, P. (2017) · Circulation: Cardiovascular Imaging · doi:10.1161/circimaging.117.006843 · Cited by 236
Quantitative imaging of cancer in the postgenomic era: Radio(geno)mics, deep learning, and habitats
Napel, S., Mu, W., Jardim‐Perassi, B. V., Aerts, H. J. W. L., & Gillies, R. J. (2018) · Cancer · doi:10.1002/cncr.31630 · Cited by 229
“Although there have been some efforts to compensate for these differences (eg, using phantoms and image interpolation), 68–73 and herculean efforts on protocol standardization by the Quantitative Imaging Biomarkers Initiative (QIBA) 74–78 currently are underway, much work remains before radiomics…”
BackgroundRobustness and Reproducibility of Radiomics in Magnetic Resonance Imaging: A Phantom Study
Baeßler, B., Weiss, K., & Pinto dos Santos, D. (2019) · Investigative Radiology · doi:10.1097/rli.0000000000000530 · Cited by 229
Voxel size and gray level normalization of CT radiomic features in lung cancer
Shafiq-ul-Hassan, M., Latifi, K., Zhang, G., Ullah, G., Gillies, R., & Moros, E. (2018) · Scientific Reports · doi:10.1038/s41598-018-28895-9 · Cited by 215
Mali, S. A., Ibrahim, A., Woodruff, H. C., Andrearczyk, V., Müller, H., Primakov, S., Salahuddin, Z., Chatterjee, A., & Lambin, P. (2021) · Journal of Personalized Medicine · doi:10.3390/jpm11090842 · Cited by 207
“Similar studies have been conducted in the past where the reproducibility of CT radiomic features was investigated using phantom data [25–27, 146 Considering MRI, a recent study using radiomics to investigate the reproducibility of features across several MRI scanners and scanning protocol…”
BackgroundMethodInfluentialZhang, Y.-P., Zhang, X.-Y., Cheng, Y.-T., Li, B., Teng, X.-Z., Zhang, J., Lam, S., Zhou, T., Ma, Z.-R., Sheng, J.-B., et al. (2023) · Military Medical Research · doi:10.1186/s40779-023-00458-8 · Cited by 199
“Mackin et al. [191] partially answered this question; they found that the variability in the values of radiomics features in phantom CT images was comparable to the variability in the values of radiomics features in NSCLC tumor CT images.”
BackgroundLigero, M., Jordi-Ollero, O., Bernatowicz, K., Garcia-Ruiz, A., Delgado-Muñoz, E., Leiva, D., Mast, R., Suarez, C., Sala-Llonch, R., Calvo, N., et al. (2021) · European Radiology · doi:10.1007/s00330-020-07174-0 · Cited by 191
van Timmeren, J. E., Leijenaar, R. T. H., van Elmpt, W., Reymen, B., Oberije, C., Monshouwer, R., Bussink, J., Brink, C., Hansen, O., & Lambin, P. (2017) · Radiotherapy and Oncology · doi:10.1016/j.radonc.2017.04.016 · Cited by 184
Hagiwara, A., Fujita, S., Ohno, Y., & Aoki, S. (2020) · Investigative Radiology · doi:10.1097/rli.0000000000000666 · Cited by 183
Fave, X., Mackin, D., Yang, J., Zhang, J., Fried, D., Balter, P., Followill, D., Gomez, D., Kyle Jones, A., Stingo, F., et al. (2015) · Medical Physics · doi:10.1118/1.4934826 · Cited by 171
Self-citationHarmonizing the pixel size in retrospective computed tomography radiomics studies
Mackin, D., Fave, X., Zhang, L., Yang, J., Jones, A. K., Ng, C. S., & Court, L. (2017) · PLOS ONE · doi:10.1371/journal.pone.0178524 · Cited by 165
Self-citationHarmonization strategies for multicenter radiomics investigations
Da-Ano, R., Visvikis, D., & Hatt, M. (2020) · Physics in Medicine & Biology · doi:10.1088/1361-6560/aba798 · Cited by 161
“Scans of the Credence Cartridge Radiomics phantom (Mackin et al 2015) were acquired using eight different CT scanners from three different manufacturers (2 General Electric (GE), 4 Siemens and 2 Philips).”
MethodAssessing Agreement between Radiomic Features Computed for Multiple CT Imaging Settings
Lu, L., Ehmke, R. C., Schwartz, L. H., & Zhao, B. (2016) · PLOS ONE · doi:10.1371/journal.pone.0166550 · Cited by 159
Understanding Sources of Variation to Improve the Reproducibility of Radiomics
Zhao, B. (2021) · Frontiers in Oncology · doi:10.3389/fonc.2021.633176 · Cited by 158
Dynamic Memory to Alleviate Catastrophic Forgetting in Continual Learning with Medical Imaging
Perkonigg, M., Hofmanninger, J., Herold, C. J., Brink, J. A., Pianykh, O., Prosch, H., & Langs, G. (2021) · Nature Communications · doi:10.1038/s41467-021-25858-z · Cited by 106
Learning from scanners: Bias reduction and feature correction in radiomics
Zhovannik, I., Bussink, J., Traverso, A., Shi, Z., Kalendralis, P., Wee, L., Dekker, A., Fijten, R., & Monshouwer, R. (2019) · Clinical and Translational Radiation Oncology · doi:10.1016/j.ctro.2019.07.003 · Cited by 75
Must-have Qualities of Clinical Research on Artificial Intelligence and Machine Learning
Koçak, B., Cuocolo, R., Santos, D. P. D., Stanzione, A., & Ugga, L. (2023) · Balkan Medical Journal · doi:10.4274/balkanmedj.galenos.2022.2022-11-51 · Cited by 64
Distributed deep learning across multisite datasets for generalized CT hemorrhage segmentation
Remedios, S. W., Roy, S., Bermudez, C., Patel, M. B., Butman, J. A., Landman, B. A., & Pham, D. L. (2020) · Medical Physics · doi:10.1002/mp.13880 · Cited by 37
“This is extremely challenging with regards to medical imaging, as there are many scanner manufacturers, models, protocols, and contrasts 28,29 in addition to the inherent biological variations.”
Metadata
- Authors
- Mackin, D., Fave, X., Zhang, L., Fried, D., Yang, J., Taylor, B., Rodriguez-Rivera, E., Dodge, C., Jones, A. K., & Court, L.
- Venue
- Investigative Radiology
- Published
- 2015-11
- Volume
- 50
- Issue
- 11
- Pages
- 757-765
- ISSN
- 0020-9996 (ISSN-L)
- OpenAlex
- W2398056625
- Cited by
- 651
- References
- 27
- FWCI
- 28.33
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.