The DOI matches its Crossref record; 16 of the 16 references it cites were found in a registry or an index.
T1-Weighted Hypersignal in the Deep Cerebellar Nuclei After Repeated Administrations of Gadolinium-Based Contrast Agents in Healthy Rats: Difference Between Linear and Macrocyclic Agents
Open accessAbstract
OBJECTIVES: To prospectively compare in healthy rats the effect of multiple injections of macrocyclic (gadoterate meglumine) and linear (gadodiamide) gadolinium-based contrast agents (GBCAs) on T1-weighted signal intensity in the deep cerebellar nuclei (DCN), including the dentate nucleus. MATERIALS AND METHODS: Healthy rats (n = 7/group) received 20 intravenous injections of 0.6 mmol of gadolinium (Gd) per kilogram (4 injections per week during 5 weeks) of gadodiamide, gadoterate meglumine, or hyperosmolar saline (control group). Brain T1-weighted magnetic resonance imaging was performed before and once a week during the 5 weeks of injections and during 5 additional weeks (treatment-free period). Gadolinium concentrations were measured with inductively coupled plasma mass spectrometry in plasma and brain. Blinded qualitative and quantitative evaluations of the T1 signal intensity in DCN were performed, as well as a statistical analysis on quantitative data. RESULTS: A significant and persistent T1 signal hyperintensity in DCN was observed only in gadodiamide-treated rats. The DCN-to-cerebellar cortex signal ratio was significantly increased from the 12th injection of gadodiamide (1.070 ± 0.024) compared to the gadoterate meglumine group (1.000 ± 0.033; P < 0.001) and control group (1.019 ± 0.022; P < 0.001) and did not significantly decrease during the treatment-free period. Total Gd concentrations in the gadodiamide group were significantly higher in the cerebellum (3.66 ± 0.91 nmol/g) compared with the gadoterate meglumine (0.26 ± 0.12 nmol/g; P < 0.05) and control (0.06 ± 0.10 nmol/g; P < 0.05) groups. CONCLUSIONS: Repeated administrations of the linear GBCA gadodiamide to healthy rats are associated with progressive and persistent T1 signal hyperintensity in the DCN, with Gd deposition in the cerebellum in contrast with the macrocyclic GBCA gadoterate meglumine for which no effect was observed.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
AChE-stained horizontal sections of the rat brain in stereotaxic coordinates
Paxinos, G., Watson, C. R. R., & Emson, P. C. (1980) · Journal of Neuroscience Methods · doi:10.1016/0165-0270(80)90021-7 · Cited by 4,497
Grobner, T. (2006) · Nephrology Dialysis Transplantation · doi:10.1093/ndt/gfk062 · Cited by 1,859
Intracranial gadolinium deposition after contrast-enhanced MR imaging
McDonald, R. J., McDonald, J. S., Kallmes, D. F., Jentoft, M. E., Murray, D. L., Thielen, K. R., Williamson, E. E., & Eckel, L. J. (2015) · Radiology · doi:10.1148/radiol.15150025 · Cited by 1,358
Kanda, T., Ishii, K., Kawaguchi, H., Kitajima, K., & Takenaka, D. (2014) · Radiology · doi:10.1148/radiol.13131669 · Cited by 1,339
Radbruch, A., Weberling, L. D., Kieslich, P. J., Eidel, O., Burth, S., Kickingereder, P., Heiland, S., Wick, W., Schlemmer, H.-P., & Bendszus, M. (2015) · Radiology · doi:10.1148/radiol.2015150337 · Cited by 561
Stability of Gadolinium-Based Magnetic Resonance Imaging Contrast Agents in Human Serum at 37°C
Frenzel, T., Lengsfeld, P., Schirmer, H., Hütter, J., & Weinmann, H.-J. (2008) · Investigative Radiology · doi:10.1097/rli.0b013e3181852171 · Cited by 539
Kanda, T., Osawa, M., Oba, H., Toyoda, K., Kotoku, J., Haruyama, T., Takeshita, K., & Furui, S. (2015) · Radiology · doi:10.1148/radiol.14140364 · Cited by 488
Errante, Y., Cirimele, V., Mallio, C. A., Di Lazzaro, V., Zobel, B. B., & Quattrocchi, C. C. (2014) · Investigative Radiology · doi:10.1097/rli.0000000000000072 · Cited by 421
Idée, J., Port, M., Raynal, I., Schaefer, M., Le Greneur, S., & Corot, C. (2006) · Fundamental & Clinical Pharmacology · doi:10.1111/j.1472-8206.2006.00447.x · Cited by 395
Self-citationBiodistribution and toxicity of MR imaging contrast media
Øksendal, A. N., & Hals, P. (1993) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.1880030128 · Cited by 156
Cited by
Gadolinium deposition in the brain: summary of evidence and recommendations
Gulani, V., Calamante, F., Shellock, F. G., Kanal, E., & Reeder, S. B. (2017) · The Lancet Neurology · doi:10.1016/s1474-4422(17)30158-8 · Cited by 784
Gadolinium-based contrast agent toxicity: a review of known and proposed mechanisms
Rogosnitzky, M., & Branch, S. (2016) · BioMetals · doi:10.1007/s10534-016-9931-7 · Cited by 766
Gadolinium-Based Contrast Agent Accumulation and Toxicity: An Update
Ramalho, J., Semelka, R. C., Ramalho, M., Nunes, R. H., AlObaidy, M., & Castillo, M. (2016) · American Journal of Neuroradiology · doi:10.3174/ajnr.a4615 · Cited by 453
Gadolinium‐based contrast agents: A comprehensive risk assessment
Fraum, T. J., Ludwig, D. R., Bashir, M. R., & Fowler, K. J. (2017) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.25625 · Cited by 402
Deep learning enables reduced gadolinium dose for contrast-enhanced brain MRI
Gong, E., Pauly, J. M., Wintermark, M., & Zaharchuk, G. (2018) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.25970 · Cited by 351
Metadata
- Authors
- Robert, P., Lehericy, S., Grand, S., Violas, X., Fretellier, N., Idée, J.-M., Ballet, S., & Corot, C.
- Venue
- Investigative Radiology
- Published
- 2015-08
- Volume
- 50
- Issue
- 8
- Pages
- 473-480
- ISSN
- 0020-9996 (ISSN-L)
- OpenAlex
- W2333063905
- Cited by
- 257
- References
- 16
- FWCI
- 17.99
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: T1-Weighted Hypersignal in the Deep Cerebellar Nuclei After Repeated Administrations of Gadolinium-Based Contrast Agents in Healthy Rats: Difference Between Linear and Macrocyclic Agents. https://app.cochat.ai/papers/10.1097/rli.0000000000000181
- The paper
- Robert, P., Lehericy, S., Grand, S., Violas, X., Fretellier, N., Idée, J.-M., Ballet, S., & Corot, C. (2015). T1-Weighted Hypersignal in the Deep Cerebellar Nuclei After Repeated Administrations of Gadolinium-Based Contrast Agents in Healthy Rats: Difference Between Linear and Macrocyclic Agents. Investigative Radiology. https://doi.org/10.1097/rli.0000000000000181
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.