Deep Learning in Mammography: Diagnostic Accuracy of a Multipurpose Image Analysis Software in the Detection of Breast Cancer
The DOI matches its Crossref record; 27 of the 27 references it cites were found in a registry or an index.
Abstract
Objectives: The aim of this study was to evaluate the diagnostic accuracy of a multipurpose image analysis software based on deep learning with artificial neural networks for the detection of breast cancer in an independent, dual-center mammography data set. Materials and Methods: In this retrospective, Health Insurance Portability and Accountability Act-compliant study, all patients undergoing mammography in 2012 at our institution were reviewed (n = 3228). All of their prior and follow-up mammographies from a time span of 7 years (2008–2015) were considered as a reference for clinical diagnosis. After applying exclusion criteria (missing reference standard, prior procedures or therapies), patients with the first diagnosis of a malignoma or borderline lesion were selected (n = 143). Histology or clinical long-term follow-up served as reference standard. In a first step, a breast density-and age-matched control cohort was selected (n = 143) from the remaining patients with more than 2 years follow-up (n = 1003). The neural network was trained with this data set. From the publicly available Breast Cancer Digital Repository data set, patients with cancer and a matched control cohort were selected (n = 35 × 2). The performance of the trained neural network was also tested with this external data set. Three radiologists (3, 5, and 10 years of experience) evaluated the test data set. In a second step, the neural network was trained with all cases from January to September and tested with cases from October to December 2012 (screening-like cohort). The radiologists also evaluated this second test data set. The areas under the receiver operating characteristic curve between readers and the neural network were compared. A Bonferroni-corrected P value of less than 0.016 was considered statistically significant. Results: Mean age of patients with lesion was 59.6 years (range, 35–88 years) and in controls, 59.1 years (35–83 years). Breast density distribution (A/B/C/D) was 21/59/42/21 and 22/60/41/20, respectively. Histologic diagnoses were invasive ductal carcinoma in 90, ductal in situ carcinoma in 13, invasive lobular carcinoma in 13, mucinous carcinoma in 3, and borderline lesion in 12 patients. In the first step, the area under the receiver operating characteristic curve of the trained neural network was 0.81 and comparable on the test cases 0.79 (P = 0.63). One of the radiologists showed almost equal performance (0.83, P = 0.17), whereas 2 were significantly better (0.91 and 0.94, P < 0.016). In the second step, performance of the neural network (0.82) was not significantly different from the human performance (0.77–0.87, P > 0.016); however, radiologists were consistently less sensitive and more specific than the neural network. Conclusions: Current state-of-the-art artificial neural networks for general image analysis are able to detect cancer in mammographies with similar accuracy to radiologists, even in a screening-like cohort with low breast cancer prevalence.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“eight91–98 studies validated algorithms on external data”
From Diagnostic accuracy of deep learning in medical imaging: a systematic review and meta-analysis (2021) · cites this paper as [91]
In the citing paper
“Sixteen studies62,91,92,94,97–107 compared algorithm performance against healthcare professionals.”
From Diagnostic accuracy of deep learning in medical imaging: a systematic review and meta-analysis (2021) · cites this paper as [91]
In the citing paper
“Only eight studies in ophthalmology imaging14,21,32,33,43,55,108,109, ten studies in respiratory imaging64,66,70,72,75,79,82,87,89,110 and six studies in breast imaging62,91,97,104,106,111 mentioned adherence to the STARD-2015 guidelines or had a STARD flow diagram in the manuscript.”
From Diagnostic accuracy of deep learning in medical imaging: a systematic review and meta-analysis (2021) · cites this paper as [91]
Citations
Cites
LeCun, Y., Bengio, Y., & Hinton, G. (2015) · Nature · doi:10.1038/nature14539 · Cited by 84,126
Intraclass correlations: Uses in assessing rater reliability.
Shrout, P. E., & Fleiss, J. L. (1979) · Psychological Bulletin · doi:10.1037/0033-2909.86.2.420 · Cited by 24,532
DeLong, E. R., DeLong, D. M., & Clarke-Pearson, D. L. (1988) · Biometrics · doi:10.2307/2531595 · Cited by 22,649
A fast learning algorithm for deep belief nets
Hinton, G. E., Osindero, S., & Teh, Y.-W. (2006) · Neural Computation · doi:10.1162/neco.2006.18.7.1527 · Cited by 16,336
Learning Deep Architectures for AI
Bengio, Y. (2009) · Foundations and Trends® in Machine Learning · doi:10.1561/2200000006 · Cited by 9,239
Matching as Nonparametric Preprocessing for Reducing Model Dependence in Parametric Causal Inference
Ho, D. E., Imai, K., King, G., & Stuart, E. A. (2007) · Political Analysis · doi:10.1093/pan/mpl013 · Cited by 4,205 · cited 1×
“An age- and breast density–matched control cohort (n = 35) was selected from patients without malignant lesions with the nearest neighbor algorithm.(14) The complete list of BCDR cases is given in Supplementary Table 1 , Supplemental Digital Content 1, http:// links.”
Method(1981) · PubMed · Cited by 2,253
Diagnostic Performance of Digital versus Film Mammography for Breast-Cancer Screening
Pisano, E. D., Gatsonis, C., Hendrick, E., Yaffe, M., Baum, J. K., Acharyya, S., Conant, E. F., Fajardo, L. L., Bassett, L., D'Orsi, C., et al. (2005) · New England Journal of Medicine · doi:10.1056/nejmoa052911 · Cited by 1,940
Unsupervised Deep Learning Applied to Breast Density Segmentation and Mammographic Risk Scoring
Kallenberg, M., Petersen, K., Nielsen, M., Ng, A. Y., Diao, P., Igel, C., Vachon, C. M., Holland, K., Winkel, R. R., Karssemeijer, N., et al. (2016) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2016.2532122 · Cited by 439 · cited 2×
“As summarized in Table 2, the diagnostic accuracy achieved by our dANN is comparable to other recently published deep learning models.(9,24,25) In contrast to the present article, these studies make use of specialized dANNs for breast cancer detection.”
MethodResultNonparametric Analysis of Clustered ROC Curve Data
Obuchowski, N. A. (1997) · Biometrics · doi:10.2307/2533958 · Cited by 429
Haas, B. M., Kalra, V., Geisel, J., Raghu, M., Durand, M., & Philpotts, L. E. (2013) · Radiology · doi:10.1148/radiol.13130307 · Cited by 419
Hubbard, R. A., Kerlikowske, K., Flowers, C. I., Yankaskas, B. C., Zhu, W., & Miglioretti, D. L. (2011) · Annals of Internal Medicine · doi:10.7326/0003-4819-155-8-201110180-00004 · Cited by 414 · cited 1×
“Recently, mammography screening programs have been criticized due to the high recall rate and high rate of false-positives resulting in unnecessary biopsies.(3,4) Although the increasing use of adjunctive new techniques such as tomosynthesis may hopefully help to decrease recall rates,(5) further efforts are necessary…”
BackgroundLong-Term Psychosocial Consequences of False-Positive Screening Mammography
Brodersen, J., & Siersma, V. D. (2013) · The Annals of Family Medicine · doi:10.1370/afm.1466 · Cited by 343 · cited 1×
“Although the increasing use of adjunctive new techniques such as tomosynthesis may hopefully help to decrease recall rates,(5) further efforts are necessary to improve the diagnostic accuracy in breast imaging,(6) considering not only monetary costs but primarily the substantial psychological burden for women receivin…”
BackgroundSardanelli, F., Podo, F., Santoro, F., Manoukian, S., Bergonzi, S., Trecate, G., Vergnaghi, D., Federico, M., Cortesi, L., Corcione, S., et al. (2011) · Investigative Radiology · doi:10.1097/rli.0b013e3181f3fcdf · Cited by 337 · cited 1×
“Hence, it may be interesting for centers caring for high-risk patients.(28) Our study has several limitations that need to be acknowledged.”
BackgroundTo recognize shapes, first learn to generate images
Hinton, G. E. (2007) · Progress in Brain Research · doi:10.1016/s0079-6123(06)65034-6 · Cited by 309
Automated Mass Detection in Mammograms Using Cascaded Deep Learning and Random Forests
Dhungel, N., Carneiro, G., & Bradley, A. P. (2015) · 2015 International Conference on Digital Image Computing: Techniques and Applications (DICTA) · doi:10.1109/dicta.2015.7371234 · Cited by 228 · cited 1×
“However, they still used a rather large amount of data (2250 cases) to train their neural networks, as do most other machine learning studies who achieved similar or higher diagnostic accuracy.(26) This is problematic,”
BackgroundAn evaluation of image descriptors combined with clinical data for breast cancer diagnosis
Moura, D. C., & Guevara, M. A. (2013) · International Journal of Computer Assisted Radiology and Surgery · doi:10.1007/s11548-013-0838-2 · Cited by 131
Salz, T., Richman, A. R., & Brewer, N. T. (2010) · Psycho-Oncology · doi:10.1002/pon.1676 · Cited by 123
Probabilistic visual search for masses within mammography images using deep learning
Ertosun, M. G., & Rubin, D. L. (2015) · 2015 IEEE International Conference on Bioinformatics and Biomedicine (BIBM) · doi:10.1109/bibm.2015.7359868 · Cited by 116 · cited 2×
“Computer-assisted detection (CADe) in mammography is nothing new, although the traditional CADe systems rely on other machine learning algorithms and hence need large amounts of reference data.(24) The underlying engine in the present study, however, is a novel more versatile form of artificial intelligence, which is…”
BackgroundResultDiscovering Mammography-based Machine Learning Classifiers for Breast Cancer Diagnosis
Ramos-Pollán, R., Guevara, M. A., Ortega, C. S., Herrero, G. D., Franco-Valiente, J. M., del Solar, M. R., de Posada, N. G., Vaz, M. A. P., Loureiro, J. A., & Ramos, I. M. (2011) · Journal of Medical Systems · doi:10.1007/s10916-011-9693-2 · Cited by 110
The Changing World of Breast Cancer: A Radiologist's Perspective
Kuhl, C. K. (2015) · Investigative Radiology · doi:10.1097/rli.0000000000000166 · Cited by 64
Guo, Y., Dong, M., Yang, Z., Gao, X., Wang, K., Luo, C., Ma, Y., & Zhang, J. (2016) · Computer Methods and Programs in Biomedicine · doi:10.1016/j.cmpb.2016.02.019 · Cited by 57 · cited 1×
“Moreover, many algorithms require preprocessing by either manual or automatic segmentation to remove extracorporeal air or the pectoral muscle.(9,25,27) In the latter case, important diagnostic information (peripheral tumors, pathologic lymph nodes) may even be lost.”
MethodJohns, L. E., & Moss, S. (2010) · Cancer Epidemiology Biomarkers & Prevention · doi:10.1158/1055-9965.epi-10-0623 · Cited by 37
Benchmarking Datasets for Breast Cancer Computer-Aided Diagnosis (CADx)
Moura, D. C., Guevara, M. A., Cunha, P., de Posada, N. G., Pollán, R. R., Ramos, I. M., Loureiro, J. P., Moreira, I. C., Araújo, B., & Fernandes, T. C. (2013) · Lecture notes in computer science · doi:10.1007/978-3-642-41822-8_41 · Cited by 27
Peters, S., Hellmich, M., Stork, A., Kemper, J., Grinstein, O., Püsken, M., Stahlhut, L., Kinner, S., Maintz, D. C., & Krug, K. B. (2016) · Investigative Radiology · doi:10.1097/rli.0000000000000334 · Cited by 25
Prediction Model For Extensive Ductal Carcinoma In Situ Around Early-Stage Invasive Breast Cancer
Knuttel, F. M., van der Velden, B. H. M., Loo, C. E., Elias, S. G., Wesseling, J., van den Bosch, M. A. A. J., & Gilhuijs, K. G. A. (2016) · Investigative Radiology · doi:10.1097/rli.0000000000000255 · Cited by 15 · cited 1×
“Furthermore, the inclusion of clinical and bioptic data may improve accuracy of the resulting model.(31) However, it may also be hypothesized that generic dANN will show a faster development in the future compared with dedicated radiological software due to the scale effects with other applications.”
BackgroundTowards localization of malignant sites of asymmetry across bilateral mammograms
Casti, P., Mencattini, A., Salmeri, M., Ancona, A., Lorusso, M., Pepe, M. L., Natale, C. D., & Martinelli, E. (2016) · Computer Methods and Programs in Biomedicine · doi:10.1016/j.cmpb.2016.11.010 · Cited by 14 · cited 1×
“The importance of these concepts is reflected in the evaluation criteria of risk stratification by the Breast Imaging Reporting And Data System lexicon, and first attempts do aid diagnosis by asymmetries have been made.(29) It may be that these new concepts will be good targets for recurrent ANNs, which have recently…”
Background
Research works printed but not linked: 1
- 2013, ACR BI-RADS® Atlas, Breast imaging reporting and data system, J Am Coll Radiol, 39
Cited by
International evaluation of an AI system for breast cancer screening
McKinney, S. M., Sieniek, M., Godbole, V., Godwin, J., Antropova, N., Ashrafian, H., Back, T., Chesus, M., Corrado, G. S., Darzi, A., et al. (2020) · Nature · doi:10.1038/s41586-019-1799-6 · Cited by 3,287
Liu, X., Faes, L., Kale, A. U., Wagner, S. K., Fu, D. J., Bruynseels, A., Mahendiran, T., Moraes, G., Shamdas, M., Kern, C., et al. (2019) · The Lancet Digital Health · doi:10.1016/s2589-7500(19)30123-2 · Cited by 1,883
Deep Learning: A Primer for Radiologists
Chartrand, G., Cheng, P. M., Vorontsov, E., Drozdzal, M., Turcotte, S., Pal, C. J., Kadoury, S., & Tang, A. (2017) · RadioGraphics · doi:10.1148/rg.2017170077 · Cited by 1,115
Diagnostic accuracy of deep learning in medical imaging: a systematic review and meta-analysis
Aggarwal, R., Sounderajah, V., Martin, G., Ting, D. S. W., Karthikesalingam, A., King, D., Ashrafian, H., & Darzi, A. (2021) · npj Digital Medicine · doi:10.1038/s41746-021-00438-z · Cited by 946
Deep Learning to Improve Breast Cancer Detection on Screening Mammography
Shen, L., Margolies, L. R., Rothstein, J. H., Fluder, E., McBride, R., & Sieh, W. (2019) · Scientific Reports · doi:10.1038/s41598-019-48995-4 · Cited by 873
Metadata
- Authors
- Becker, A. S., Marcon, M., Ghafoor, S., Wurnig, M. C., Frauenfelder, T., & Boss, A.
- Affiliations
- University Hospital Zurich (CH)
- Corresponding author
- Becker, Anton S.
- Venue
- Investigative Radiology
- Published
- 2017-07
- Volume
- 52
- Issue
- 7
- Pages
- 434-440
- ISSN
- 0020-9996 (ISSN-L)
- 1536-0210
- OpenAlex
- W2588570836
- Semantic Scholar
- b757776861a430dafa3d4ad2729f173716c88e23
- Cited by
- 352
- References
- 27
- Citations by year
- 2026: 9 · 2025: 25 · 2024: 35 · 2023: 39 · 2022: 59 · 2021: 47 · 2020: 47 · 2019: 46 · 2018: 36 · 2017: 8
- FWCI
- 22.35
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- Investigative Radiology (publishedVersion)
- PubMed (publishedVersion)
- Zurich Open Repository and Archive (University of Zurich) (submittedVersion)
- Funders
- Bracco Imaging
- Topics
- Physical Sciences › Computer Science › Artificial Intelligence › AI in cancer detection
- Health Sciences › Medicine › Radiology, Nuclear Medicine and Imaging › Digital Radiography and Breast Imaging
- Health Sciences › Medicine › Radiology, Nuclear Medicine and Imaging › Radiomics and Machine Learning in Medical Imaging
- Keywords
- breast cancer detection, mammography, deep learning, artificial neural networks, computer-aided detection, diagnostic accuracy, invasive ductal carcinoma, breast density, external validation, radiologist comparison, mammography screening, borderline breast lesions, ductal carcinoma in situ, invasive lobular carcinoma, mucinous carcinoma, invasive mucinous carcinoma
- MeSH terms
- Machine Learning, Adult, Aged, Aged, 80 and over, Breast, Breast Neoplasms, Female, Follow-Up Studies, Humans, Image Processing, Computer-Assisted, Mammography, Middle Aged, Retrospective Studies, ROC Curve, Reproducibility of Results, Prevalence
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.