Quantification of Myocardial Perfusion Using Dynamic 64-Detector Computed Tomography
The DOI matches its Crossref record; 21 of the 21 references it cites were found in a registry or an index.
Abstract
OBJECTIVES: The purpose of this study was to determine the ability of dynamic 64 slice multidetector computed tomography (d-MDCT) to provide an accurate measurement of myocardial blood flow (MBF) during first-pass d-MDCT using semiquantitative and quantitative analysis methods. MATERIALS AND METHODS: Six dogs with a moderate to severe left-anterior descending artery stenosis underwent adenosine (0.14 mL . kg-1 . min-1) stress d-MDCT imaging according to the following imaging protocol: iopamidol 10 mL/s for 3 seconds, 8 mm x 4 collimation, 400 milliseconds gantry rotation time, 120 kV, and 60 mAs. Images were reconstructed at 1-second intervals. Regions of interest were drawn in the LAD and remote territories, and time-attenuation curves were constructed. Myocardial perfusion was analyzed using a model-based deconvolution method and 2 upslope methods and compared with the microsphere MBF measurements. RESULTS: The myocardial upslope-to-LV-upslope and myocardial upslope-to-LV-max ratio strongly correlated with MBF (R2 = 0.92, P < 0.0001 and R2 = 0.87, P < 0.0001, respectively). Absolute MBF derived by model-based deconvolution analysis modestly overestimated MBF compared with microsphere MBF (3.0 +/- 2.5 mL . g-1 . min-1 vs. 2.6 +/- 2.7 mL . g-1 . min-1, respectively). Overall, MDCT-derived MBF strongly correlated with microspheres (R = 0.91, P < 0.0001, mean difference: 0.45 mL . g-1 . min-1, P = NS). CONCLUSIONS: d-MDCT MBF measurements using upslope and model-based deconvolution methods correlate well with microsphere MBF. These methods may become clinically applicable in conjunction with coronary angiography and next generation MDCT scanners with larger detector arrays and full cardiac coverage.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT
Martin Bland, J., & Altman, D. (1986) · The Lancet · doi:10.1016/s0140-6736(86)90837-8 · Cited by 47,965
(1965) · The Lancet · doi:10.1016/s0140-6736(65)91037-8 · Cited by 16,856
Diagnostic Accuracy of Noninvasive Coronary Angiography Using 64-Slice Spiral Computed Tomography
Raff, G. L., Gallagher, M. J., O’Neill, W. W., & Goldstein, J. A. (2005) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2005.05.056 · Cited by 1,472
Quantification of Obstructive and Nonobstructive Coronary Lesions by 64-Slice Computed Tomography
Leber, A. W., Knez, A., von Ziegler, F., Becker, A., Nikolaou, K., Paul, S., Wintersperger, B., Reiser, M., Becker, C. R., Steinbeck, G., et al. (2005) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2005.03.071 · Cited by 1,109
Mollet, N. R., Cademartiri, F., van Mieghem, C. A. G., Runza, G., McFadden, E. P., Baks, T., Serruys, P. W., Krestin, G. P., & de Feyter, P. J. (2005) · Circulation · doi:10.1161/circulationaha.105.533471 · Cited by 1,018
Al-Saadi, N., Nagel, E., Gross, M., Bornstedt, A., Schnackenburg, B., Klein, C., Klimek, W., Oswald, H., & Fleck, E. (2000) · Circulation · doi:10.1161/01.cir.101.12.1379 · Cited by 578 · cited 1×
“Two adaptations of previously published upslope methods applied to MRI perfusion studies were used to semiquantitatively measure myocardial perfusion.(11,12) The upslope of the myocardial TAC was calculated by using time-attenuation data points starting at the time contrast was first detected entering the LV blood poo…”
MethodGeorge, J., Carr, E., Davies, J., Belch, J. J. F., & Struthers, A. (2006) · Circulation · doi:10.1161/circulationaha.106.651117 · Cited by 569
Schuijf, J. D., Wijns, W., Jukema, J. W., Atsma, D. E., de Roos, A., Lamb, H. J., Stokkel, M. P. M., Dibbets-Schneider, P., Decramer, I., De Bondt, P., et al. (2006) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2006.05.080 · Cited by 479 · cited 4×
“Preliminary studies, both published and works in progress, are highlighting the differences between MDCT angiography and radionuclide MPI.5,6 Although noninvasive MDCT angiography detects atherosclerosis in its early to late stages and delineates coronary anatomy in three-dimensional detail, it lacks the capability to…”
BackgroundResultInfluentialN-13 ammonia as an indicator of myocardial blood flow.
Schelbert, H. R., Phelps, M. E., Huang, S. C., MacDonald, N. S., Hansen, H. W., Selin, C. E., & Kuhl, D. E. (1981) · Circulation · doi:10.1161/01.cir.63.6.1259 · Cited by 452 · cited 1×
“Using diffusible tracers and applying compartmental modeling, tracers such as (13)N ammonia and (15)O water have been used for the accurate quantification of MBF.(28,29) However, (15)O water is not approved for clinical use in the United States, and (13)N ammonia requires a cyclotron on-site due to its short half-life…”
MethodMicrovascular Rheology and Hemodynamics
LIPOWSKY, H. H. (2005) · Microcirculation · doi:10.1080/10739680590894966 · Cited by 414
Cited by
Coronary microvascular dysfunction: mechanisms and functional assessment
Camici, P. G., d'Amati, G., & Rimoldi, O. (2015) · Nature Reviews Cardiology · doi:10.1038/nrcardio.2014.160 · Cited by 498
Adenosine-Induced Stress Myocardial Perfusion Imaging Using Dual-Source Cardiac Computed Tomography
Blankstein, R., Shturman, L. D., Rogers, I. S., Rocha-Filho, J. A., Okada, D. R., Sarwar, A., Soni, A. V., Bezerra, H., Ghoshhajra, B. B., Petranovic, M., et al. (2009) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2009.06.014 · Cited by 392
George, R. T., Arbab-Zadeh, A., Miller, J. M., Kitagawa, K., Chang, H.-J., Bluemke, D. A., Becker, L., Yousuf, O., Texter, J., Lardo, A. C., et al. (2009) · Circulation: Cardiovascular Imaging · doi:10.1161/circimaging.108.813766 · Cited by 324
Self-citationBamberg, F., Becker, A., Schwarz, F., Marcus, R. P., Greif, M., von Ziegler, F., Blankstein, R., Hoffmann, U., Sommer, W. H., Hoffmann, V. S., et al. (2011) · Radiology · doi:10.1148/radiol.11110638 · Cited by 275
Noninvasive Assessment of Myocardial Perfusion
Salerno, M., & Beller, G. A. (2009) · Circulation: Cardiovascular Imaging · doi:10.1161/circimaging.109.854893 · Cited by 211
Stress Myocardial Perfusion: Imaging with Multidetector CT
Rossi, A., Merkus, D., Klotz, E., Mollet, N., de Feyter, P. J., & Krestin, G. P. (2014) · Radiology · doi:10.1148/radiol.13112739 · Cited by 200
George, R. T., Arbab-Zadeh, A., Miller, J. M., Vavere, A. L., Bengel, F. M., Lardo, A. C., & Lima, J. A. C. (2012) · Circulation: Cardiovascular Imaging · doi:10.1161/circimaging.111.969303 · Cited by 183
Self-citationInflammation in Coronary Microvascular Dysfunction
Sagris, M., Theofilis, P., Antonopoulos, A. S., Oikonomou, E., Paschaliori, C., Galiatsatos, N., Tsioufis, K., & Tousoulis, D. (2021) · International Journal of Molecular Sciences · doi:10.3390/ijms222413471 · Cited by 115
Metadata
- Authors
- George, R. T., Jerosch-Herold, M., Silva, C., Kitagawa, K., Bluemke, D. A., Lima, J. A. C., & Lardo, A. C.
- Venue
- Investigative Radiology
- Published
- 2007-12
- Volume
- 42
- Issue
- 12
- Pages
- 815-822
- ISSN
- 0020-9996 (ISSN-L)
- OpenAlex
- W2071683327
- Cited by
- 251
- References
- 21
- FWCI
- 17.56
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.