CoChat

DNA Double-Strand Breaks and Their Repair in Blood Lymphocytes of Patients Undergoing Angiographic Procedures

Kuefner, Michael A., Grudzenski, Saskia, Schwab, Siegfried A., Wiederseiner, Melanie, Heckmann, Martina, Bautz, Werner, Lobrich, Markus, Uder, Michael · 2009 · Investigative Radiology
Cited by 99

The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.

Abstract

OBJECTIVES: To adapt gamma-H2AX immunofluorescence microscopy to assessment of induction and repair of DNA double-strand breaks (DSBs) in peripheral blood lymphocytes in patients undergoing angiographic procedures. MATERIALS AND METHODS: The study was approved by the institutional ethics committee. After written informed patient consents were obtained, venous blood samples were taken from 19 patients (age 23-88 years) undergoing different angiographic procedures before, during, and after (10 minutes-24 hours) the examination. Individual DSB yields were visualized by detecting the phosphorylated variant of the histone H2AX (gamma-H2AX) in lymphocytes using fluorescence microscopy. Values were correlated with dose area product. Single in vitro irradiation with 50 mGy was performed in 14 and additional fractionated irradiation with 10 x 5 mGy over a time period corresponding to the angiography duration in 4 patients. The radiation doses to the blood delivered during angiography were estimated by comparing the number of DSBs after angiography with DSB yields obtained after in vitro irradiation. RESULTS: In all patients in vivo and in vitro irradiation increased the number of DSBs (0.03-1.50 per cell), even if very small doses were applied (minimum 338 microGy x m). Thereafter in both in vitro and in vivo a rapid loss of gamma-H2AX foci was observed. The number of DSBs showed a linear correlation to dose area product for specific examination regions (eg, R = 0.85, pelvic and leg arteries). Calculated radiation doses to blood delivered during angiography ranged from 2.2 to 99.9 mGy and increased if fractioned in vitro samples were used as calibration instead of single in vitro irradiations at the same total dose. CONCLUSIONS: gamma-H2AX immunofluorescence microscopy is a reliable and sensitive method for measuring the induction and repair of DNA damage caused by ionizing radiation during angiography. To estimate radiation doses delivered during procedures and to consider patients individual repair capacity, postangiography DSB-yields should be compared with DSB-yields after fractioned in vitro irradiation imitating examination conditions.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1097/rli.0b013e3181a654a5

Cites

3 of 3 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 3 references

Cited by

See all 99

Metadata

Authors
Kuefner, M. A., Grudzenski, S., Schwab, S. A., Wiederseiner, M., Heckmann, M., Bautz, W., Lobrich, M., & Uder, M.
Venue
Investigative Radiology
Published
2009-08
Volume
44
Issue
8
Pages
440-446
ISSN
0020-9996 (ISSN-L)
OpenAlex
W2046500195
Cited by
99
References
3
FWCI
6.34
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: DNA Double-Strand Breaks and Their Repair in Blood Lymphocytes of Patients Undergoing Angiographic Procedures. https://app.cochat.ai/papers/10.1097/rli.0b013e3181a654a5
The paper
Kuefner, M. A., Grudzenski, S., Schwab, S. A., Wiederseiner, M., Heckmann, M., Bautz, W., Lobrich, M., & Uder, M. (2009). DNA Double-Strand Breaks and Their Repair in Blood Lymphocytes of Patients Undergoing Angiographic Procedures. Investigative Radiology. https://doi.org/10.1097/rli.0b013e3181a654a5

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.