Silk Fibroin Conduits: A Cellular and Functional Assessment of Peripheral Nerve Repair
Open accessThe DOI matches its Crossref record.
Abstract
Silk fibroin conduits were designed with appropriate porosity for peripheral nerve repair. The aim of this work was to use these conduits to examine cell inflammatory responses and functional recovery in a sciatic nerve defect model. A total of 45 randomized Lewis rats were used to create an 8-mm defect bridged by a silk guide, commercial collagen guide, or an autograft. After 1, 4, and 8 weeks, macrophage recruitment, percentage of newly formed collagen, number of myelinated axons, and gastrocnemius muscle mass were evaluated. Following 8 weeks, ED1+ cells in autograft and silk conduits decreased to <1% and 17% of week 1 values, respectively. Collagen formation revealed no difference for all measured time points, suggesting a similar foreign body response. Myelinated axon counts within the silk guide revealed a greater number of proximal spouts and distal connections than collagen guides. Gastrocnemius weights demonstrated a 27% decrease between silk and autografts after 8 weeks. This study demonstrates that, in addition to tailorable degradation rates, our silk conduits possess a favorable immunogenicity and remyelination capacity for nerve repair.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Elastomeric biomaterials for tissue engineering
Chen, Q., Liang, S., & Thouas, G. A. (2013) · Progress in Polymer Science · doi:10.1016/j.progpolymsci.2012.05.003 · Cited by 564
In vivo bioresponses to silk proteins
Thurber, A. E., Omenetto, F. G., & Kaplan, D. L. (2015) · Biomaterials · doi:10.1016/j.biomaterials.2015.08.039 · Cited by 453
Self-citationNew insights and perspectives into biological materials for flexible electronics
Wang, L., Chen, D., Jiang, K., & Shen, G. (2017) · Chemical Society Reviews · doi:10.1039/c7cs00278e · Cited by 410
Tien, L. W., Wu, F., Tang‐Schomer, M. D., Yoon, E., Omenetto, F. G., & Kaplan, D. L. (2013) · Advanced Functional Materials · doi:10.1002/adfm.201203716 · Cited by 136
Self-citationSilk fibroin methacrylation: chemical synthesis to biomechanical optimization in tissue engineering
Wu, C. A., Zhu, Y., & Woo, Y. J. (2025) · ACS Biomaterials Science & Engineering · doi:10.1021/acsbiomaterials.4c01931 · Cited by 17
Metadata
- Authors
- Ghaznavi, A. M., Kokai, L. E., Lovett, M. L., Kaplan, D. L., & Marra, K. G.
- Venue
- Annals of Plastic Surgery
- Published
- 2011-03
- Volume
- 66
- Issue
- 3
- Pages
- 273-279
- ISSN
- 0148-7043 (ISSN-L)
- OpenAlex
- W1979364486
- Cited by
- 76
- References
- 0
- FWCI
- 2.84
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Silk Fibroin Conduits: A Cellular and Functional Assessment of Peripheral Nerve Repair. https://app.cochat.ai/papers/10.1097/sap.0b013e3181e6cff7
- The paper
- Ghaznavi, A. M., Kokai, L. E., Lovett, M. L., Kaplan, D. L., & Marra, K. G. (2011). Silk Fibroin Conduits: A Cellular and Functional Assessment of Peripheral Nerve Repair. Annals of Plastic Surgery. https://doi.org/10.1097/sap.0b013e3181e6cff7
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.