Measuring Cranial Vault Volume With Three-Dimensional Photography: A Method of Measurement Comparable to the Gold Standard
The DOI matches its Crossref record.
Abstract
The gold standard for measuring cranial vault volume is a computed tomography (CT) scan. Computed tomography scans in the pediatric population carry the significant risk of inducing a malignancy later in life. In a novel study, we show that a three-dimensional (3D) photograph can be used to measure and track cranial vault volume changes in craniosynostosis patients. In a study of adequate power as determined by pre hoc analysis, we demonstrate a greater than 0.91 correlation coefficient between volume as measured by CT and 3D photograph in more than 70 patients presenting to a tertiary craniofacial center (P < 0.001). Volume above a plane running through the lateral canthus (ex) and tragus (t) sag-ex-t on the digital 3D photograph differs from CT by a mean percentage difference of 31.9% (SD, 14.0%; 95% confidence interval, P < 0.0001). A linear regression model was used to determine the equation describing the relationship between volume as measured by 3D photograph and CT; with this equation, the absolute volume of the cranial vault is easily determined using only the 3D image. Interrater reliability is high (>0.99, ICC). The ability to measure cranial vault volume from the 3D photograph adds an important dimension to the complete and objective analysis of skull growth and postoperative change.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Seruya, M., Tan, S. Y., Wray, A. C., Penington, A. J., Greensmith, A. L., Holmes, A. D., & Chong, D. K. (2013) · Plastic and Reconstructive Surgery · doi:10.1097/prs.0b013e31829f4b3d · Cited by 35
Self-citationWeathers, W. M., Khechoyan, D., Wolfswinkel, E. M., Mohan, K., Nagy, A., Bollo, R. J., Buchanan, E. P., & Hollier, L. H. (2014) · Craniomaxillofacial Trauma & Reconstruction · doi:10.1055/s-0033-1356758 · Cited by 35
Seeberger, R., Hoffmann, J., Freudlsperger, C., Berger, M., Bodem, J., Horn, D., & Engel, M. (2016) · Journal of Cranio-Maxillofacial Surgery · doi:10.1016/j.jcms.2016.01.023 · Cited by 25
Mertens, C., Wessel, E., Berger, M., Ristow, O., Hoffmann, J., Kansy, K., Freudlsperger, C., Bächli, H., & Engel, M. (2017) · Journal of Cranio-Maxillofacial Surgery · doi:10.1016/j.jcms.2017.09.019 · Cited by 22
“Recently, 3D photography has been introduced as a valuable alternative to CT scans for the objective analysis of skull growth (Agrawal et al., 2006; Fearon et al., 2007; McKay et al., 2010; Wilbrand et al., 2012).”
BackgroundMethodInfluential3D Analysis of the Cranial and Facial Shape in Craniosynostosis Patients: A Systematic Review
Kurniawan, M. S. I. C., Tio, P. A. E., Abdel Alim, T., Roshchupkin, G., Dirven, C. M. F., Pleumeekers, M. M., Mathijssen, I. M. J., & van Veelen, M.-L. C. (2024) · Journal of Craniofacial Surgery · doi:10.1097/scs.0000000000010071 · Cited by 16
Metadata
- Authors
- McKay, D. R., Davidge, K. M., Williams, S. K., Ellis, L. A., Chong, D. K., Teixeira, R. P., Greensmith, A. L., & Holmes, A. D.
- Venue
- Journal of Craniofacial Surgery
- Published
- 2010-09
- Volume
- 21
- Issue
- 5
- Pages
- 1419-1422
- ISSN
- 1049-2275 (ISSN-L)
- OpenAlex
- W2321141785
- Cited by
- 74
- References
- 0
- FWCI
- 1.34
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Measuring Cranial Vault Volume With Three-Dimensional Photography: A Method of Measurement Comparable to the Gold Standard. https://app.cochat.ai/papers/10.1097/scs.0b013e3181ebe92a
- The paper
- McKay, D. R., Davidge, K. M., Williams, S. K., Ellis, L. A., Chong, D. K., Teixeira, R. P., Greensmith, A. L., & Holmes, A. D. (2010). Measuring Cranial Vault Volume With Three-Dimensional Photography: A Method of Measurement Comparable to the Gold Standard. Journal of Craniofacial Surgery. https://doi.org/10.1097/scs.0b013e3181ebe92a
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.