CoChat

Initial Experience With Biologic Polymer Scaffold (Poly-4-hydroxybuturate) in Complex Abdominal Wall Reconstruction

Buell, Joseph F., Sigmon, David, Ducoin, Christopher, Shapiro, Max, Teja, Nikhil, Wynter, Emmett, Hanisee, Mary K., Parker, Geoffrey, Kandil, Emad, Darden, Michael · 2017 · Annals of Surgery
Cited by 66

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

Abstract

OBJECTIVE: To evaluate the use of the new absorbable polymer scaffold poly-4-hydroxybutyrate (P4HB) in complex abdominal wall reconstruction. BACKGROUND: Complex abdominal wall reconstruction has witnessed tremendous success in the last decade after the introduction of cadaveric biologic scaffolds. However, the use of cadaveric biologic mesh has been expensive and plagued by complications such as seroma, infection, and recurrent hernia. Despite widespread application of cadaveric biologic mesh, little data exist on the superiority of these materials in the setting of high-risk wounds in patients. P4HB, an absorbable polymer scaffold, may present a new alternative to these cadaveric biologic grafts. METHODS: A retrospective analysis of our initial experience with the absorbable polymer scaffold P4HB compared with a consecutive contiguous group treated with porcine cadaveric mesh for complex abdominal wall reconstructions. Our analysis was performed using SAS 9.3 and Stata 12. RESULTS: The P4HB group (n = 31) experienced shorter drain time (10.0 vs 14.3 d; P < 0.002), fewer complications (22.6% vs 40.5%; P < 0.046), and reherniation (6.5% vs 23.8%; P < 0.049) than the porcine cadaveric mesh group (n = 42). Multivariate analysis for infection identified: porcine cadaveric mesh odds ratio 2.82, length of stay odds ratio 1.11; complications: drinker odds ratio 6.52, porcine cadaveric mesh odds ratio 4.03, African American odds ratio 3.08, length of stay odds ratio 1.11; and hernia recurrence: porcine cadaveric mesh odds ratio 5.18, drinker odds ratio 3.62, African American odds ratio 0.24. Cost analysis identified that P4HB had a $7328.91 financial advantage in initial hospitalization and $2241.17 in the 90-day postdischarge global period resulting in $9570.07 per case advantage over porcine cadaveric mesh. CONCLUSIONS: In our early clinical experience with the absorbable polymer matrix scaffold P4HB, it seemed to provide superior clinical performance and value-based benefit compared with porcine cadaveric biologic mesh.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1097/sla.0000000000001916

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 1 references

Cited by

See all 66

Metadata

Authors
Buell, J. F., Sigmon, D., Ducoin, C., Shapiro, M., Teja, N., Wynter, E., Hanisee, M. K., Parker, G., Kandil, E., & Darden, M.
Venue
Annals of Surgery
Published
2017-07
Volume
266
Issue
1
Pages
185-188
ISSN
0003-4932 (ISSN-L)
OpenAlex
W2508668385
Cited by
66
References
1
FWCI
4.65
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Initial Experience With Biologic Polymer Scaffold (Poly-4-hydroxybuturate) in Complex Abdominal Wall Reconstruction. https://app.cochat.ai/papers/10.1097/sla.0000000000001916
The paper
Buell, J. F., Sigmon, D., Ducoin, C., Shapiro, M., Teja, N., Wynter, E., Hanisee, M. K., Parker, G., Kandil, E., & Darden, M. (2017). Initial Experience With Biologic Polymer Scaffold (Poly-4-hydroxybuturate) in Complex Abdominal Wall Reconstruction. Annals of Surgery. https://doi.org/10.1097/sla.0000000000001916

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.