Fully resorbable poly-4-hydroxybutyrate (P4HB) mesh for soft tissue repair and reconstruction: A scoping review
Abstract
Background: Poly-4-hydroxybutyrate (P4HB) is a fully resorbable, biologically-produced polymer with a strength and flexibility comparable to permanent synthetic polymers. The objective was to identify/summarize all peer-reviewed publications involving P4HB mesh. Methods: A scoping review was conducted within PubMed and included articles published through October 2022. Results: A total of n = 79 studies were identified (n = 12 in vitro/bench; n = 14 preclinical; n = 6 commentaries; n = 50 clinical). Of the clinical studies, n = 40 reported results applicable to hernia and n = 10 to plastic/reconstructive surgery and involved patients of all Centers for Disease Control (CDC) wound classes and Ventral Hernia Working Group (VHWG) grades. Conclusion: P4HB mesh provides long-term hernia repair strength and exhibits promising clinical outcomes beyond its resorption period. Future studies should include randomized controlled trials comparing P4HB to other biomaterials, as well as optimal patient selection, operative technique, long-term outcomes, minimization of potential mesh-related complications, and potential contraindications/complications for P4HB in hernia/abdominal wall reconstruction.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“clinical studies have extended these findings, documenting outcomes comparable to other mesh materials (4).”
In the citing paper
“a recent scoping review identified a knowledge gap in umbilical and small to medium-sized, routine ventral hernias (4).”
In the citing paper
“Bench and preclinical studies have established the long-term strength and durability of P4HB”
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
PRISMA Extension for Scoping Reviews (PRISMA-ScR): Checklist and Explanation
Tricco, A. C., Lillie, E., Zarin, W., O'Brien, K. K., Colquhoun, H., Levac, D., Moher, D., Peters, M. D. J., Horsley, T., Weeks, L., et al. (2018) · Annals of Internal Medicine · doi:10.7326/m18-0850 · Cited by 43,565
Roth, J. S., Anthone, G. J., Selzer, D. J., Poulose, B. K., Pierce, R. A., Bittner, J. G., Hope, W. W., Dunn, R. M., Martindale, R. G., Goldblatt, M. I., et al. (2021) · Annals of Medicine and Surgery · doi:10.1016/j.amsu.2020.12.002 · Cited by 40
Self-citation
Research works printed but not linked: 91
- Martin, 2003, Medical applications of poly-4-hydroxybutyrate: a strong flexible absorbable biomaterial, Biochem Engr J, 16, 97, 10.1089/107632703322066660 · DOI
- Shen, 2019, A facile method to prepare high molecular weight bio-renewable poly(γ-butyrolactone) using a strong base/urea binary synergistic catalytic system, Polym Chem, 10, 1231, 10.1039/c8py01812j · DOI
- Yuan, 2021, Bioabsorbable poly(4-hydroxybutyrate) (P4HB) fibrous membranes as a potential dermal substitute, J Mater Chem B, 9, 8074, 10.1039/d1tb01271a · DOI
- Hong, Angew Chem Int Ed Engl, 10.1002/anie.201601092 · DOI · Paper page
- Williams, 2013, Poly-4-hydroxybutyrate (P4HB): a new generation of resorbable medical devices for tissue repair and regeneration, Biomed Tech (Berl), 58, 439, 10.1515/bmt-2013-0009 · DOI
- Martin, 2013, Characterization of poly-4-hydroxybutyrate mesh for hernia repair applications, J Surg Res, 184, 766, 10.1016/j.jss.2013.03.044 · DOI · Paper page
- Williams, 2016, The history of GalaFLEX P4HB scaffold, Aesthet Surg J, 36, S33, 10.1093/asj/sjw141 · DOI · Paper page
- Singhi, 2021, The effect of wet spinning conditions on the structure and properties of poly-4-hydroxybutyrate fibers, J Biomed Mater Res Part B Appl Biomater, 109, 982, 10.1002/jbm.b.34763 · DOI
- van Driel, 2021, Observational cohort study on the use of a slowly fully resorbable synthetic mesh (phasix™) in the treatment of complex abdominal wall pathology with different grades of contamination, Surg Technol Int, 38, 186, 10.52198/21.sti.38.hr1418 · DOI
- Hope, 2022, A prospective, multicenter trial of a long-term bioabsorbable mesh with sepra technology in cohort of challenging laparoscopic ventral or incisional hernia repairs (ATLAS trial), Ann Med Surg (Lond), 73, 103156, 10.1016/j.amsu.2021.103156 · DOI · Paper page
- Adams WP, 2017, Use of poly-4-hydroxybutyrate mesh to optimize soft-tissue support in mastopexy: a single-site study, Plast Reconstr Surg, 139, 67, 10.1097/PRS.0000000000002922 · DOI
- Wormer, 2017, Reducing postoperative abdominal bulge following deep inferior epigastric perforator flap breast reconstruction with onlay monofilament poly-4-hydroxybutyrate biosynthetic mesh, J Reconstr Microsurg, 33, 8, 10.1055/s-0036-1586495 · DOI
- Levy, 2020, Poly-4-hydroxybutyric acid mesh compares favorably with acellular dermal matrix in tissue expander-based breast reconstruction, Ann Plast Surg, 85, S2, 10.1097/SAP.0000000000002339 · DOI
- Adams WP, 2016, Clinical use of GalaFLEX in facial and breast cosmetic plastic surgery, Aesthet Surg J, 36, S23, 10.1093/asj/sjw142 · DOI
- Baxter, 2016, Internal bra: a unifying solution for reconstructive and aesthetic breast surgery issues, Plast Aesthet Res, 3, 3, 10.20517/2347-9264.2015.68 · DOI
- Adams WP, 2018, The use of poly-4-hydroxybutyrate (P4HB) scaffold in the ptotic breast: a multicenter clinical study, Aesthet Surg J, 38, 502, 10.1093/asj/sjy022 · DOI
- Calobrace, 2020, Popcorn capsulorrhaphy in revision aesthetic breast surgery, Aesthet Surg J, 40, 63, 10.1093/asj/sjy324 · DOI
- Mallucci, 2022, Experience and indications for the use of the P4HB scaffold (galaflex) in aesthetic breast surgery: 100 case experience, Aesthet Surg J, 10.1093/asj/sjac198 · DOI
- Sigalove, 2022, Evaluation of the safety of a GalaFLEX-AlloDerm construct in prepectoral breast reconstruction, Plast Reconstr Surg, 150, 75S, 10.1097/PRS.0000000000009520 · DOI
- Angelos, 2014, Biomechanical properties of superficial musculoaponeurotic system tissue with vs without reinforcement with poly-4-hydroxybutyric acid absorbable mesh, JAMA Facial Plast Surg, 16, 199, 10.1001/jamafacial.2013.2738 · DOI
- Diedrich, 2022, Evaluation of the short-term host response and biomechanics of an absorbable poly-4-hydroxybutyrate scaffold in a sheep model following vaginal implantation, BJOG, 129, 1039, 10.1111/1471-0528.17040 · DOI
- O'Shaughnessy, 2021, Evaluation of the histological and biomechanical properties of poly-4-hydroxybutyrate scaffold for pelvic organ prolapse, compared with polypropylene mesh in a rabbit model, Int Urogynecol J, 33, 2213, 10.1007/s00192-021-04851-6 · DOI
- Rostaminia, 2021, A commentary on “evaluation of the histological and biomechanical properties of poly-4-hydroxybutyrate (P4HB) scaffold for pelvic organ prolapse, as compared to polypropylene mesh in a rabbit model”, Int Urogynecol J, 33, 2221, 10.1007/s00192-021-04944-2 · DOI
- Verhorstert, 2022, The impact of bacterial contamination on the host response towards fully absorbable poly-4-hydroxybutyrate and nonabsorbable polypropylene pelvic floor implants, Mater Today Bio, 15, 100268, 10.1021/acsami.0c14668 · DOI
- Faulkner, 2021, Evaluation of absorbable mesh for prophylactic mesh augmentation in high-risk patients, Surg Technol Int, 38, 213, 10.52198/21.STI.38.HR1430 · DOI
- Aldohayan, 2020, A novel use of fully absorbable phasix(TM) mesh for laparoscopic inguinal hernia repair, J Soc Laparoendosc Surg/Soc Laparoendosc Surg, 24, e2020.00041, 10.04293/JSLS.02020.00041 · DOI
- Panici Tonucci, 2020, Safety and efficacy of crura augmentation with phasix ST mesh for large hiatal hernia: 3-year single-center experience, J Laparoendosc Adv Surg Tech A, 30, 369, 10.1089/lap.2019.0726 · DOI
- Buell, 2021, Long-term outcomes in complex abdominal wall reconstruction repaired with absorbable biologic polymer scaffold (poly-4-hydroxybutyrate), Ann Surg, 1, 1, 10.1097/as9.0000000000000032 · DOI · Paper page
- Roth, 2022, Long-term, prospective, multicenter study of P4HB (phasix™) mesh for hernia repair in cohort at risk for complications: 60-months follow-up, J Am Coll Surg, 10.1097/XCS.0000000000000363 · DOI
- Breuing, 2010, Incisional ventral hernias: review of the literature and recommendations regarding the grading and technique of repair, Surgery, 148, 544, 10.1016/j.surg.2010.01.008 · DOI
- Kanters, 2012, Modified hernia grading scale to stratify surgical site occurrence after open ventral hernia repairs, J Am Coll Surg, 215, 787, 10.1016/j.jamcollsurg.2012.08.012 · DOI
- Pineda Molina, 2019, 4-Hydroxybutyrate promotes endogenous antimicrobial peptide expression in macrophages, Tissue Engr Part A, 25, 693, 10.1089/ten.tea.2018.0377 · DOI
- Pineda Molina, 2019, Comparison of the host macrophage response to synthetic and biologic surgical meshes used for ventral hernia repair, J Immunol Regen Med, 3, 13, 10.1016/j.regen.2018.12.002 · DOI
- Trapani, 2020, Analysis of resorbable mesh implants in short-term human muscular fascia cultures: a pilot study, Hernia, 24, 1283, 10.1007/s10029-020-02271-x · DOI
- Verhorstert, 2020, In vitro bacterial adhesion and biofilm formation on fully absorbable poly-4-hydroxybutyrate and nonabsorbable polypropylene pelvic floor implants, ACS Appl Mater Interfaces, 12, 53646, 10.1021/acsami.0c14668 · DOI
- Diedrich, 2021, Fully absorbable poly-4-hydroxybutyrate implants exhibit more favorable cell-matrix interactions than polypropylene, Mater Sci Eng C Mater Biol Appl, 120, 111702, 10.1016/j.msec.2020.111702 · DOI
- Mora-Navarro, 2021, Transcriptome-targeted analysis of human peripheral blood-derived macrophages when cultured on biomaterial meshes, Biomed Mater, 16, 025006, 10.1088/1748-605X/abdbdb · DOI
- Pineda Molina, 2021, Role of 4-hydroxybutyrate in increased resistance to surgical site infections associated with surgical meshes, Biomaterials, 267, 120493, 10.1016/j.biomaterials.2020.120493 · DOI
- Deeken, 2013, Characterization of the mechanical strength, resorption properties, and histologic characteristics of a fully absorbable material (poly-4-hydroxybutyrate-PHASIX mesh) in a porcine model of hernia repair, ISRN Surg, 2013, 238067, 10.1155/2013/238067 · DOI · Paper page
- Scott, 2016, Evaluation of a fully absorbable poly-4-hydroxybutyrate/absorbable barrier composite mesh in a porcine model of ventral hernia repair, Surg Endosc, 30, 3691, 10.1007/s00464-016-5057-9 · DOI
- Stoikes, 2017, Characterization of host response, resorption, and strength properties, and performance in the presence of bacteria for fully absorbable biomaterials for soft tissue repair, Hernia, 21, 771, 10.1007/s10029-017-1638-3 · DOI
- Miserez, 2019, Resorbable synthetic meshes for abdominal wall defects in preclinical setting: a literature review, J Surg Res, 237, 67, 10.1016/j.jss.2018.11.054 · DOI
- Deeken, 2020, Mechanical and histological characteristics of phasix™ ST mesh in a porcine model of hernia repair, J Invest Surg, 1, 10.1080/08941939.2020.1830318 · DOI
- Pascual, 2020, Long term comparative evaluation of two types of absorbable meshes in partial abdominal wall defects: an experimental study in rabbits, Hernia, 24, 1159, 10.1007/s10029-020-02201-x · DOI
- Pascual, 2022, Behaviour at the peritoneal interface of next-generation prosthetic materials for hernia repair, Surg Endosc, 36, 579, 10.1007/s00464-021-08320-5 · DOI
- Buell, 2017, Initial experience with biologic polymer scaffold (poly-4-hydroxybuturate) in complex abdominal wall reconstruction, Ann Surg, 266, 185, 10.1097/SLA.0000000000001916 · DOI
- Plymale, 2018, Ventral hernia repair with poly-4-hydroxybutyrate mesh, Surg Endosc, 32, 1689, 10.1007/s00464-017-5848-7 · DOI · Paper page
- Roth, 2018, Prospective evaluation of poly-4-hydroxybutyrate mesh in CDC class I/high-risk ventral and incisional hernia repair: 18-month follow-up, Surg Endosc, 32, 1929, 10.1007/s00464-017-5886-1 · DOI · Paper page
- van Rooijen, 2018, A post-market, prospective, multi-center, single-arm clinical investigation of phasix mesh for VHWG grade 3 midline incisional hernia repair: a research protocol, BMC Surg, 18, 104, 10.1186/s12893-018-0439-7 · DOI
- Kniepeiss, 2019, PRevention of INCisional hernia after liver transplantation (PRINC trial): study protocol for a randomized controlled trial, Trials, 20, 371, 10.1186/s13063-019-3477-2 · DOI
- Messa, 2019, When the mesh goes away: an analysis of poly-4-hydroxybutyrate mesh for complex hernia repair, Plast Reconstr Surg Glob Open, 7, e2576, 10.1097/GOX.0000000000002576 · DOI
- Nair, 2019, Poly-4-hydroxybutyrate (P4HB) scaffold internal support: preliminary experience with direct implant opposition during complex breast revisions, Aesthet Surg J, 39, 1203, 10.1093/asj/sjy276 · DOI
- Abdelmoaty, 2020, Combination of surgical technique and bioresorbable mesh reinforcement of the crural repair leads to low early hernia recurrence rates with laparoscopic paraesophageal hernia repair, J Gastroint Surg, 24, 1477, 10.1007/s11605-019-04358-y · DOI
- Aiolfi, 2022, Laparoscopic posterior cruroplasty: a patient tailored approach, Hernia, 26, 619, 10.1007/s10029-020-02188-5 · DOI
- Mellia, 2020, Outcomes of poly-4-hydroxybutyrate mesh in ventral hernia repair: a systematic review and pooled analysis, Plast Reconstr Surg Glob Open, 8, e3158, 10.1097/GOX.0000000000003158 · DOI
- Pakula, 2020, Outcomes of open complex ventral hernia repairs with retromuscular placement of poly-4-hydroxybutyrate bioabsorbable mesh, Surg Innov, 27, 32, 10.1177/1553350619881066 · DOI
- Rehnke, 2020, Breast reconstruction using a three-dimensional absorbable mesh scaffold and autologous fat grafting: a composite strategy based on tissue-engineering principles, Plast Reconstr Surg, 146, 409e, 10.1097/PRS.0000000000007172 · DOI
- Rognoni, 2020, Clinical outcomes and quality of life associated with the use of a biosynthetic mesh for complex ventral hernia repair: analysis of the “Italian hernia club” registry, Sci Rep, 10, 10706, 10.1038/s41598-020-67821-w · DOI
- van Rooijen, 2020, Outcomes of a new slowly resorbable biosynthetic mesh (phasix™) in potentially contaminated incisional hernias: a prospective, multi-center, single-arm trial, Int J Surg, 83, 31, 10.1016/j.ijsu.2020.08.053 · DOI
- Yu, 2020, Comparison of phasix, polypropylene, and primary closure of the abdominal donor site after bilateral free flap breast reconstruction: long-term evaluation of abdominal hernia and bulge formation, Microsurgery, 40, 434, 10.1002/micr.30541 · DOI
- Aldohayan, 2021, Laparoscopic ventral hernia repair with poly-4-hydroxybutyrate absorbable barrier composite mesh, J Soc Laparoendosc Surg/Soc Laparoendosc Surg, 25, 10.4293/JSLS.2020.00105 · DOI
- Bueno-Lledó, 2020, Abdominal wall reconstruction with biosynthetic absorbable mesh after infected prosthesis explantation: single stage is better than two-stage approach of chronic mesh infection, Hernia, 25, 1005, 10.1007/s10029-020-02309-0 · DOI
- Bueno-Lledó, 2021, Biosynthetic resorbable prosthesis is useful in single-stage management of chronic mesh infection after abdominal wall hernia repair, World J Surg, 45, 443, 10.1007/s00268-020-05808-4 · DOI
- Charleux-Muller, 2021, Slowly absorbable mesh in contaminated incisional hernia repair: results of a French multicenter study, Hernia, 25, 1051, 10.1007/s10029-020-02366-5 · DOI
- Charleux-Muller, 2021, Cost-effectiveness analysis of resorbable biosynthetic mesh in contaminated ventral hernia repair, J Visc Surg, 159, 29, 10.1016/j.jviscsurg.2021.06.001 · DOI
- Christopher, 2021, An evaluation of clinical and quality of life outcomes after ventral hernia repair with poly-4-hydroxybutyrate mesh, Hernia, 25, 717, 10.1007/s10029-021-02394-9 · DOI
- Christopher, 2021, Onlay poly-4-hydroxybutyrate (P4HB) mesh for complex hernia: early clinical and patient reported outcomes, J Surg Res, 264, 199, 10.1016/j.jss.2021.02.012 · DOI
- Christopher, 2021, Resorbable synthetic ventral hernia repair in contaminated fields: outcomes with poly-4-hydroxybutyrate mesh, Plast Reconstr Surg, 148, 1367, 10.1097/PRS.0000000000008579 · DOI
- Claessen, 2021, Outcomes of mid-term and long-term degradable biosynthetic meshes in single-stage open complex abdominal wall reconstruction, Hernia, 1, 10.1007/s10029-021-02415-7 · DOI
- Lambrecht, 2021, Successful conservative treatment of a poly-4-hydroxybutyrate mesh infection: a case report, Ann Med Surg (Lond), 63, 102162, 10.1016/j.amsu.2021.02.008 · DOI
- Levy, 2021, Poly-4-hydroxybutyrate (phasix™) mesh onlay in complex abdominal wall repair, Surg Endosc, 35, 2049, 10.1007/s00464-020-07601-9 · DOI · Paper page
- van Rooijen, 2021, Slowly resorbable biosynthetic mesh: 2-year results in VHWG grade 3 hernia repair, Hernia, 26, 131, 10.1007/s10029-021-02453-1 · DOI
- Vauclair, 2021, What results can be expected one year after complex incisional hernia repair with biosynthetic mesh?, J Visc Surg, 158, 111, 10.1016/j.jviscsurg.2020.07.008 · DOI
- Aiolfi, 2022, Medium-term safety and efficacy profile of paraesophageal hernia repair with phasix-ST((R)) mesh: a single-institution experience, Hernia, 26, 279, 10.1007/s10029-021-02528-z · DOI
- Konstantinidis, 2022, Surgical treatment of large and complicated hiatal hernias with the new resorbable mesh with hydrogel barrier (phasix ST): a preliminary study, J Robot Surg, 10.1007/s11701-022-01406-9 · DOI
- Layer, 2022, Incisional hernia repair with a slowly absorbable P4HB mesh: what happens after the mesh disappears? A retrospective longitudinal clinical study, Hernia, 10.1007/s10029-022-02616-8 · DOI · Paper page
- Lima, 2022, Versatility of poly-4-hydroxybutyrate (phasix) mesh in abdominal wall surgery, Arq Gastroenterol, 59, 226, 10.1590/S0004-2803.202202000-41 · DOI
- Othman, 2022, Comparative effectiveness analysis of resorbable synthetic onlay and biologic intraperitoneal mesh for abdominal wall reconstruction: a 2-year match-paired analysis, Plast Reconstr Surg, 149, 1204, 10.1097/PRS.0000000000009021 · DOI · Paper page
- Schecter, 2022, Single-stage abdominal wall reconstruction in contaminated and dirty wounds is safe: a single center experience, Surg Endosc, 36, 5766, 10.1007/s00464-022-09058-4 · DOI
- Talwar, 2022, Shifting the goalpost in ventral hernia care: 5-year outcomes after ventral hernia repair with poly-4-hydroxybutyrate mesh, Hernia, 10.1007/s10029-022-02674-y · DOI · Paper page
- Berrevoet, 2020, The transition from experimental data to clinical practice using P4HB mesh in ventral hernia repair, J Invest Surg, 1, 10.1080/08941939.2020.1849467 · DOI
- Haddock, 2020, Discussion: breast reconstruction using a three-dimensional absorbable mesh scaffold and autologous fat grafting: a composite strategy based on tissue-engineering principles, Plast Reconstr Surg, 146, 414e, 10.1097/PRS.0000000000007175 · DOI
- Morales-Conde, 2022, Establishing peer consensus about the use of long-term biosynthetic absorbable mesh for hernia (grades 2–3) as the standard of care, World J Surg, 10.1007/s00268-022-06743-2 · DOI
- Lake, 2019, Contamination of hybrid hernia meshes compared to bioresorbable phasix mesh in a rabbit subcutaneous implant inoculation model, Ann Med Surg (Lond), 46, 12, 10.1016/j.amsu.2019.08.004 · DOI
- Levy, 2020, Poly-4-hydroxybutyrate (phasix) mesh onlay in complex abdominal wall repair, Surg Endosc, 35, 2049, 10.1007/s00464-020-07601-9 · DOI · Paper page
- Kokotovic, 2016, Long-term recurrence and complications associated with elective incisional hernia repair, JAMA, 316, 1575, 10.1001/jama.2016.15217 · DOI · Paper page
- Carbonell, 2013, Outcomes of synthetic mesh in contaminated ventral hernia repairs, J Am Coll Surg, 217, 991, 10.1016/j.jamcollsurg.2013.07.382 · DOI · Paper page
- Warren, 2020, Safety and efficacy of synthetic mesh for ventral hernia repair in a contaminated field, J Am Coll Surg, 230, 405, 10.1016/j.jamcollsurg.2019.12.008 · DOI · Paper page
- Burger, 2004, Long-term follow-up of a randomized controlled trial of suture versus mesh repair of incisional hernia, Ann Surg, 240, 578, 10.1097/01.sla.0000141193.08524.e7 · DOI · Paper page
- Rosen, 2017, Multicenter, prospective, longitudinal study of the recurrence, surgical site infection, and quality of life after contaminated ventral hernia repair using biosynthetic absorbable mesh: the COBRA study, Ann Surg, 265, 205, 10.1097/SLA.0000000000001601 · DOI · Paper page
- Itani, 2012, Prospective study of single-stage repair of contaminated hernias using a biologic porcine tissue matrix: the RICH study, Surgery, 152, 498, 10.1016/j.surg.2012.04.008 · DOI · Paper page
Cited by
Deeken, C. R., Rosen, M. J., Poulose, B. K., Bradbury, K., Huang, L.-C., Ma, J., & Badhwar, A. (2023) · Frontiers in Surgery · doi:10.3389/fsurg.2023.1280991 · Cited by 7
Self-citation
Metadata
- Authors
- Deeken, C. R., Chen, D. C., Lopez-Cano, M., Martin, D. P., & Badhwar, A.
- Venue
- Frontiers in Surgery
- Publisher
- Frontiers Media SA
- Published
- 2023-04-12
- Volume
- 10
- ISSN
- 2296-875X
- Cited by
- 32
- References
- 2
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Fully resorbable poly-4-hydroxybutyrate (P4HB) mesh for soft tissue repair and reconstruction: A scoping review. https://app.cochat.ai/papers/10.3389/fsurg.2023.1157661
- The paper
- Deeken, C. R., Chen, D. C., Lopez-Cano, M., Martin, D. P., & Badhwar, A. (2023). Fully resorbable poly-4-hydroxybutyrate (P4HB) mesh for soft tissue repair and reconstruction: A scoping review. Frontiers in Surgery. https://doi.org/10.3389/fsurg.2023.1157661
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.