Tissue-engineered Vascular Grafts Demonstrate Evidence of Growth and Development When Implanted in a Juvenile Animal Model
Open accessThe DOI matches its Crossref record.
Abstract
INTRODUCTION: The development of a living, autologous vascular graft with the ability to grow holds great promise for advancing the field of pediatric cardiothoracic surgery. OBJECTIVE: To evaluate the growth potential of a tissue-engineered vascular graft (TEVG) in a juvenile animal model. METHODS: Polyglycolic acid nonwoven mesh tubes (3-cm length, 1.3-cm id; Concordia Fibers) coated with a 10% copolymer solution of 50:50 L-lactide and epsilon-caprolactone were statically seeded with 1 x 10 cells/cm autologous bone marrow derived mononuclear cells. Eight TEVGs (7 seeded, 1 unseeded control) were implanted as inferior vena cava (IVC) interposition grafts in juvenile lambs. Subjects underwent bimonthly magnetic resonance angiography (Siemens 1.5 T) with vascular image analysis (www.BioimageSuite.org). One of 7-seeded grafts was explanted after 1 month and all others were explanted 6 months after implantation. Neotissue was characterized using qualitative histologic and immunohistochemical staining and quantitative biochemical analysis. RESULTS: All grafts explanted at 6 months were patent and increased in volume as measured by difference in pixel summation in magnetic resonance angiography at 1 month and 6 months. The volume of seeded TEVGs at explant averaged 126.9% +/- 9.9% of their volume at 1 month. Magnetic resonance imaging demonstrated no evidence of aneurysmal dilation. TEVG resembled the native IVC histologically and had comparable collagen (157.9 +/- 26.4 microg/mg), elastin (186.9 +/- 16.7 microg/mg), and glycosaminoglycan (9.7 +/- 0.8 microg/mg) contents. Immunohistochemical staining and Western blot analysis showed that Ephrin-B4, a determinant of normal venous development, was acquired in the seeded grafts 6 months after implantation. CONCLUSIONS: TEVGs demonstrate evidence of growth and venous development when implanted in the IVC of a juvenile lamb model.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
The return of a forgotten polymer—Polycaprolactone in the 21st century
Woodruff, M. A., & Hutmacher, D. W. (2010) · Progress in Polymer Science · doi:10.1016/j.progpolymsci.2010.04.002 · Cited by 4,033
Roh, J. D., Sawh-Martinez, R., Brennan, M. P., Jay, S. M., Devine, L., Rao, D. A., Yi, T., Mirensky, T. L., Nalbandian, A., Udelsman, B., et al. (2010) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0911465107 · Cited by 559
Self-citationRecent Advances in Bioplastics: Application and Biodegradation
Narancic, T., Cerrone, F., Beagan, N., & O’Connor, K. E. (2020) · Polymers · doi:10.3390/polym12040920 · Cited by 421
Substrates for cardiovascular tissue engineering
Bouten, C. V. C., Dankers, P. Y. W., Driessen-Mol, A., Pedron, S., Brizard, A. M. A., & Baaijens, F. P. T. (2011) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2011.01.007 · Cited by 261
Radke, D., Jia, W., Sharma, D., Fena, K., Wang, G., Goldman, J., & Zhao, F. (2018) · Advanced Healthcare Materials · doi:10.1002/adhm.201701461 · Cited by 256
Hibino, N., Yi, T., Duncan, D. R., Rathore, A., Dean, E., Naito, Y., Dardik, A., Kyriakides, T., Madri, J., Pober, J. S., et al. (2011) · The FASEB Journal · doi:10.1096/fj.11-186585 · Cited by 231
“In addition, results of postoperative serial imaging confirmed the results of our preclinical studies demonstrating the growth capacity of the TEVG, making it the first human-made vascular conduit with growth potential (6, 10).”
ResultSelf-citationUnified Framework for Development, Deployment and Robust Testing of Neuroimaging Algorithms
Joshi, A., Scheinost, D., Okuda, H., Belhachemi, D., Murphy, I., Staib, L. H., & Papademetris, X. (2011) · Neuroinformatics · doi:10.1007/s12021-010-9092-8 · Cited by 227
Current Strategies for the Manufacture of Small Size Tissue Engineering Vascular Grafts
Carrabba, M., & Madeddu, P. (2018) · Frontiers in Bioengineering and Biotechnology · doi:10.3389/fbioe.2018.00041 · Cited by 219
“PGA is the most extensively explored material having been used in sheep (Brennan et al., 2008; Cummings et al., 2012), dogs, pigs (Quint et al., 2011) and primate models.”
BackgroundOff-the-shelf human decellularized tissue-engineered heart valves in a non-human primate model
Weber, B., Dijkman, P. E., Scherman, J., Sanders, B., Emmert, M. Y., Grünenfelder, J., Verbeek, R., Bracher, M., Black, M., Franz, T., et al. (2013) · Biomaterials · doi:10.1016/j.biomaterials.2013.04.059 · Cited by 188
Tissue engineering of acellular vascular grafts capable of somatic growth in young lambs
Syedain, Z., Reimer, J., Lahti, M., Berry, J., Johnson, S., Bianco, R., & Tranquillo, R. T. (2016) · Nature Communications · doi:10.1038/ncomms12951 · Cited by 170
“To this end, two groups have previously demonstrated growth potential of synthetic biodegradable grafts seeded with autologous cells 13,22–24 .”
InfluentialConcise Review: Tissue-Engineered Vascular Grafts for Cardiac Surgery: Past, Present, and Future
Kurobe, H., Maxfield, M. W., Breuer, C. K., & Shinoka, T. (2012) · Stem Cells Translational Medicine · doi:10.5966/sctm.2012-0044 · Cited by 162
Self-citationStem cell sources for vascular tissue engineering and regeneration
Bajpai, V. K., & Andreadis, S. T. (2012) · Tissue Engineering Part B: Reviews · doi:10.1089/ten.teb.2011.0264 · Cited by 95
Battiston, K. G., Labow, R. S., & Santerre, J. P. (2012) · Biomaterials · doi:10.1016/j.biomaterials.2012.08.014 · Cited by 53
Metadata
- Authors
- Brennan, M. P., Dardik, A., Hibino, N., Roh, J. D., Nelson, G. N., Papademitris, X., Shinoka, T., & Breuer, C. K.
- Venue
- Annals of Surgery
- Published
- 2008-09
- Volume
- 248
- Issue
- 3
- Pages
- 370-377
- ISSN
- 0003-4932 (ISSN-L)
- OpenAlex
- W2070213995
- Cited by
- 157
- References
- 0
- FWCI
- 11.64
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.