Sentinel Node Mapping Guided by Indocyanine Green Fluorescence Imaging in Gastric Cancer
The DOI matches its Crossref record; 11 of the 11 references it cites were found in a registry or an index.
Abstract
In Brief Objective: In this study, we determined the possible usefulness of sentinel node (SN) mapping guided by indocyanine green (ICG) fluorescence imaging in the management of gastric cancer. Summary Background Data: ICG fluorescence imaging system has recently been developed for obtaining biochemical information from living tissues. Methods: Our series consisted of 56 patients with gastric cancer who underwent standard gastrectomy with lymphadenectomy. Two milliliters of ICG solution (0.5%) was injected into the submucosa around the tumor endoscopically before the operation or into the subserosa intraoperatively. ICG fluorescence imaging was conducted using a charge-coupled device camera with a light-emitting diode having a wavelength of 760 nm as the light source and a cut filter to filter out light with wavelengths below 820 nm as the detector. Results: SNs were detected in 54 (96.4%) of the 56 patients, and the mean number of SNs was 7.2 ± 7.0. Even SNs that were not green in color could be easily and clearly visualized by ICG fluorescence imaging. cT1-stage cancers were associated with a significantly higher accuracy rate (97.2% vs. 72.2%, P = 0.0127) than cT2-or cT3-stage cancers. Preoperative ICG injection was associated with a significantly higher incidence of cT1-stage cancers (87.1% vs. 40.0%, P = 0.0004), a larger mean number of SNs (9.9 ± 7.5 vs. 4.1 ± 5.0, P < 0.0001), a higher accuracy rate (100% vs. 73.9%, P = 0.0039), and a lower false negative rate (0% vs. 60.0%, P = 0.0345) as compared with intraoperative ICG injection. Conclusions: This study shows that ICG fluorescence imaging allows highly sensitive image-guided intraoperative SN mapping in cases of gastric cancer. Our data suggest that SN mapping guided by ICG fluorescence imaging might be useful for predicting the metastatic status in lymph nodes in cases of gastric cancer, especially those with cT1-stage cancer. In this study, we described a new method of indocyanine green fluorescence imaging, which allows highly sensitive image-guided intraoperative sentinel node mapping in cases of gastric cancer. Our data suggest that sentinel node mapping guided by indocyanine green fluorescence imaging might be useful for predicting the metastatic status in lymph nodes in cases of gastric cancer, especially those with cT1-stage cancer.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Technical Details of Intraoperative Lymphatic Mapping for Early Stage Melanoma
Morton, D. L. (1992) · Archives of Surgery · doi:10.1001/archsurg.1992.01420040034005 · Cited by 4,371
Japanese Classification of Gastric Carcinoma – 2nd English Edition –
Japanese Gastric Cancer Association (1998) · Gastric Cancer · doi:10.1007/pl00011681 · Cited by 2,170
Fluorescence navigation with indocyanine green for detecting sentinel lymph nodes in breast cancer
Kitai, T., Inomoto, T., Miwa, M., & Shikayama, T. (2005) · Breast Cancer · doi:10.2325/jbcs.12.211 · Cited by 677 · cited 3×
“ICG fluorescence imaging was carried out using the Infrared Camera System (Hamamatsu Photonics, Hamamatsu, Japan).(21,24) The light source was a light-emitting diode that emitted light at a wavelength of 760 nm, and the detector was a charge-coupled device (CCD) camera with a cut filter used to filter out light with w…”
BackgroundMethodSelf-citationGastric cancer treatment guidelines in Japan
Nakajima, T. (2002) · Gastric Cancer · doi:10.1007/s101200200000 · Cited by 569 · cited 2×
“All patients underwent curative gastrectomy, including laparoscopic gastrectomy, with lymphadenectomy according to the Guidelines of the Japanese Gastric Cancer Association.23 From the *Division of General and Gastroenterological Surgery, Department of Surgery, Showa University, School of Medicine, Tokyo; and †Central…”
MethodKusano, M., Tajima, Y., Yamazaki, K., Kato, M., Watanabe, M., & Miwa, M. (2008) · Digestive Surgery · doi:10.1159/000121905 · Cited by 315 · cited 2×
“ICG fluorescence imaging was carried out using the Infrared Camera System (Hamamatsu Photonics, Hamamatsu, Japan).(21,24) The light source was a light-emitting diode that emitted light at a wavelength of 760 nm, and the detector was a charge-coupled device (CCD) camera with a cut filter used to filter out light with w…”
BackgroundMethodSelf-citationBinding properties of indocyanine green in human blood.
Yoneya, S., Saito, T., Komatsu, Y., Koyama, I., Takahashi, K., & Duvoll-Young, J. (1998) · PubMed · Cited by 246
Miyashiro, I., Miyoshi, N., Hiratsuka, M., Kishi, K., Yamada, T., Ohue, M., Ohigashi, H., Yano, M., Ishikawa, O., & Imaoka, S. (2008) · Annals of Surgical Oncology · doi:10.1245/s10434-008-9872-7 · Cited by 185 · cited 1×
“In addition, ICG fluorescence leakage from injured lymphatic vessels during SN mapping is a great disadvantage of intraoperative subserosal ICG injection.(26) Thus, the differences in the mean number of SNs and such technical factors might be responsible for the aforementioned differences in the accuracy and false neg…”
BackgroundHayashi, H., Ochiai, T., Mori, M., Karube, T., Suzuki, T., Gunji, Y., Hori, S., Akutsu, N., Matsubara, H., & Shimada, H. (2003) · Journal of the American College of Surgeons · doi:10.1016/s1072-7515(02)01594-6 · Cited by 146
Arigami, T., Natsugoe, S., Uenosono, Y., Mataki, Y., Ehi, K., Higashi, H., Arima, H., Yanagida, S., Ishigami, S., Hokita, S., et al. (2006) · Annals of Surgery · doi:10.1097/01.sla.0000201453.65534.f1 · Cited by 127
An intraoperative fluorescent imaging system in organ transplantation
Sekijima, M., Tojimbara, T., Sato, S., Nakamura, M., Kawase, T., Kai, K., Urashima, Y., Nakajima, I., FUCHINOUE, S., & Teraoka, S. (2004) · Transplantation Proceedings · doi:10.1016/j.transproceed.2004.09.001 · Cited by 104
Cited by
Image-guided cancer surgery using near-infrared fluorescence
Vahrmeijer, A. L., Hutteman, M., van der Vorst, J. R., van de Velde, C. J. H., & Frangioni, J. V. (2013) · Nature Reviews Clinical Oncology · doi:10.1038/nrclinonc.2013.123 · Cited by 1,466
A Review of Indocyanine Green Fluorescent Imaging in Surgery
Alander, J. T., Kaartinen, I., Laakso, A., Pätilä, T., Spillmann, T., Tuchin, V. V., Venermo, M., & Välisuo, P. (2012) · International Journal of Biomedical Imaging · doi:10.1155/2012/940585 · Cited by 1,352
Hartgrink, H. H., Jansen, E. P., van Grieken, N. C., & van de Velde, C. J. (2009) · The Lancet · doi:10.1016/s0140-6736(09)60617-6 · Cited by 875
Schaafsma, B. E., Mieog, J. S. D., Hutteman, M., van der Vorst, J. R., Kuppen, P. J. K., Löwik, C. W. G. M., Frangioni, J. V., van de Velde, C. J. H., & Vahrmeijer, A. L. (2011) · Journal of Surgical Oncology · doi:10.1002/jso.21943 · Cited by 816
Chi, C., Du, Y., Ye, J., Kou, D., Qiu, J., Wang, J., Tian, J., & Chen, X. (2014) · Theranostics · doi:10.7150/thno.9899 · Cited by 358
Near-Infrared Fluorescence Imaging in Humans with Indocyanine Green: A Review and Update
Marshall, M. V., Rasmussen, J. C., Tan, I.-C., Aldrich, M. B., Adams, K. E., Wang, X., Fife, C. E., Maus, E. A., Smith, L. A., & Sevick-Muraca, E. M. (2010) · The Open Surgical Oncology Journal · doi:10.2174/1876504101002010012 · Cited by 341
van Manen, L., Handgraaf, H. J. M., Diana, M., Dijkstra, J., Ishizawa, T., Vahrmeijer, A. L., & Mieog, J. S. D. (2018) · Journal of Surgical Oncology · doi:10.1002/jso.25105 · Cited by 322
“One study in gastric cancer prefers injection (endoscopically) 1 day before surgery.(36) They showed lower false negative results than intraoperatively subserosal injection, probably becauseof frequent leakage fromdamaged lymphatic vessels, causedby”
BackgroundChen, Q.-Y., Xie, J.-W., Zhong, Q., Wang, J.-B., Lin, J.-X., Lu, J., Cao, L.-L., Lin, M., Tu, R.-H., Huang, Z.-N., et al. (2020) · JAMA Surgery · doi:10.1001/jamasurg.2019.6033 · Cited by 300
Polom, K., Murawa, D., Rho, Y., Nowaczyk, P., Hünerbein, M., & Murawa, P. (2011) · Cancer · doi:10.1002/cncr.26087 · Cited by 251
A review of performance of near-infrared fluorescence imaging devices used in clinical studies
Zhu, B., & Sevick-Muraca, E. M. (2015) · The British Journal of Radiology · doi:10.1259/bjr.20140547 · Cited by 175
Intraoperative fluorescent imaging using indocyanine green for liver mapping and cholangiography
Aoki, T., Murakami, M., Yasuda, D., Shimizu, Y., Kusano, T., Matsuda, K., Niiya, T., Kato, H., Murai, N., Otsuka, K., et al. (2010) · Journal of Hepato-Biliary-Pancreatic Sciences · doi:10.1007/s00534-009-0197-0 · Cited by 162
“Recently, illumination with near-infrared light has been employed to detect sentinel lymph nodes in breast [10, 11], gastric [12–14], lung [15, 16] and esophageal cancers [17] and to intraoperatively assess graft patency [18, 19].”
BackgroundSelf-citation
Metadata
- Authors
- Tajima, Y., Yamazaki, K., Masuda, Y., Kato, M., Yasuda, D., Aoki, T., Kato, T., Murakami, M., Miwa, M., & Kusano, M.
- Venue
- Annals of Surgery
- Published
- 2009-01
- Volume
- 249
- Issue
- 1
- Pages
- 58-62
- ISSN
- 0003-4932 (ISSN-L)
- OpenAlex
- W2080348261
- Cited by
- 221
- References
- 11
- FWCI
- 11.69
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.