The DOI matches its Crossref record.
Practice Patterns and Outcomes of Retrievable Vena Cava Filters in Trauma Patients: An AAST Multicenter Study
Abstract
BACKGROUND: The purpose of this study is to describe practice patterns and outcomes of posttraumatic retrievable inferior vena caval filters (R-IVCF). METHODS: A retrospective review of R-IVCFs placed during 2004 at 21 participating centers with follow up to July 1, 2005 was performed. Primary outcomes included major complications (migration, pulmonary embolism [PE], and symptomatic caval occlusion) and reasons for failure to retrieve. RESULTS: Of 446 patients (69% male, 92% blunt trauma) receiving R-IVCFs, 76% for prophylactic indications and 79% were placed by interventional radiology. Excluding 33 deaths, 152 were Gunter-Tulip (G-T), 224 Recovery (R), and 37 Optease (Opt). Placement occurred 6 +/- 8 days after admission and retrieval at 50 +/- 61 days. Follow up after discharge (5.7 +/- 4.3 months) was reported in 51%. Only 22% of R-IVCFs were retrieved. Of 115 patients in whom retrieval was attempted, retrieval failed as a result of technical issues in 15 patients (10% of G-T, 14% of R, 27% of Opt) and because of significant residual thrombus within the filter in 10 patients (6% of G-T, 4% of R, 46% Opt). The primary reason R-IVCFs were not removed was because of loss to follow up (31%), which was sixfold higher (6% to 44%, p = 0.001) when the service placing the R-IVCF was not directly responsible for follow up. Complications did not correlate with mechanism, injury severity, service placing the R-IVCF, trauma volume, use of anticoagulation, age, or sex. Three cases of migration were recorded (all among R, 1.3%), two breakthrough PE (G-T 0.6% and R 0.4%) and six symptomatic caval occlusions (G-T 0, R 1%, Opt 11%) (p < 0.05 Opt versus both G-T and R). CONCLUSION: Most R-IVCFs are not retrieved. The service placing the R-IVCF should be responsible for follow up. The Optease was associated with the greatest incidence of residual thrombus and symptomatic caval occlusion. The practice patterns of R-IVCF placement and retrieval should be re-examined.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Prevention of Venous Thromboembolism
Geerts, W. H., Pineo, G. F., Heit, J. A., Bergqvist, D., Lassen, M. R., Colwell, C. W., & Ray, J. G. (2004) · Chest · doi:10.1378/chest.126.3_suppl.338s · Cited by 5,895
Prevention of Venous Thromboembolism
Geerts, W. H., Bergqvist, D., Pineo, G. F., Heit, J. A., Samama, C. M., Lassen, M. R., & Colwell, C. W. (2008) · Chest · doi:10.1378/chest.08-0656 · Cited by 3,829
2014 ESC Guidelines on the diagnosis and management of acute pulmonary embolism
Authors/Task Force Members, Konstantinides, S. V., Torbicki, A., Agnelli, G., Danchin, N., Fitzmaurice, D., Galiè, N., Gibbs, J. S. R., Huisman, M. V., Humbert, M., et al. (2014) · European Heart Journal · doi:10.1093/eurheartj/ehu283 · Cited by 3,128
Guidelines on the diagnosis and management of acute pulmonary embolism
Authors/Task Force Members, Torbicki, A., Perrier, A., Konstantinides, S., Agnelli, G., Galiè, N., Pruszczyk, P., Bengel, F., Brady, A. J. B., Ferreira, D., et al. (2008) · European Heart Journal · doi:10.1093/eurheartj/ehn310 · Cited by 2,826
Systematic Review of the Use of Retrievable Inferior Vena Cava Filters
Angel, L. F., Tapson, V., Galgon, R. E., Restrepo, M. I., & Kaufman, J. (2011) · Journal of Vascular and Interventional Radiology · doi:10.1016/j.jvir.2011.08.024 · Cited by 474
Metadata
- Authors
- Karmy-Jones, R., Jurkovich, G. J., Velmahos, G. C., Burdick, T., Spaniolas, K., Todd, S. R., McNally, M., Jacoby, R. C., Link, D., Janczyk, R. J., Ivascu, F. A., McCann, M., Obeid, F., Hoff, W. S., McQuay, N., Tieu, B. H., Schreiber, M. A., Nirula, R., Brasel, K., Dunn, J. A., Gambrell, D., Huckfeldt, R., Harper, J., Schaffer, K. B., Tominaga, G. T., Vinces, F. Y., Sperling, D., Hoyt, D., Coimbra, R., Rosengart, M. R., Forsythe, R., Cothren, C., Moore, E. E., Haut, E. R., Hayanga, A. J., Hird, L., White, C., Grossman, J., Nagy, K., Livaudais, W., Wood, R., Zengerink, I., & Kortbeek, J. B.
- Venue
- The Journal of Trauma: Injury, Infection, and Critical Care
- Published
- 2007-01
- Volume
- 62
- Issue
- 1
- Pages
- 17-25
- ISSN
- 0022-5282 (ISSN-L)
- OpenAlex
- W2055004524
- Cited by
- 233
- References
- 0
- FWCI
- 18.88
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Practice Patterns and Outcomes of Retrievable Vena Cava Filters in Trauma Patients: An AAST Multicenter Study. https://app.cochat.ai/papers/10.1097/ta.0b013e31802dd72a
- The paper
- Karmy-Jones, R., Jurkovich, G. J., Velmahos, G. C., Burdick, T., Spaniolas, K., Todd, S. R., McNally, M., Jacoby, R. C., Link, D., Janczyk, R. J., Ivascu, F. A., McCann, M., Obeid, F., Hoff, W. S., McQuay, N., Tieu, B. H., Schreiber, M. A., Nirula, R., Brasel, K., . . . Kortbeek, J. B. (2007). Practice Patterns and Outcomes of Retrievable Vena Cava Filters in Trauma Patients: An AAST Multicenter Study. The Journal of Trauma: Injury, Infection, and Critical Care. https://doi.org/10.1097/ta.0b013e31802dd72a
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.