CoChat

Clinical Utility of the Cobalt-Albumin Binding Assay in the Diagnosis of Intestinal Ischemia

Polk, Jonathan D., Rael, Leonard T., Craun, Michael L., Mains, Charles W., Davis-Merritt, Deborah, Bar-Or, David · 2008 · Journal of Trauma: Injury, Infection & Critical Care
Cited by 47

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

Abstract

Currently, the rapid diagnosis of mesenteric ischemia is problematic because of the nonspecificity of most laboratory assays and the unreliability of physical examinations. The evaluation of the cobalt-albumin binding assay (CABA) as a diagnostic marker for short-term risk stratification of emergency department patients presenting with symptoms of intestinal ischemia is reported. This preliminary study includes patients scheduled for exploratory laparotomy with symptoms of ischemic bowel and/or bowel obstruction. Approximately 10 mL of blood was drawn from each patient 1 hour preoperatively into a serum separator gel tube. After 30 minutes of clotting time, serum was collected and frozen at -80 degrees C. The CABA test was performed on the samples by an investigator blinded to the patient's condition, and values were compared with the clinical and pathologic diagnosis of ischemic bowel postoperatively. CABA test values are reported as absorbance units (ABSU) at 470 nm. Of the 26 patients enrolled in the study, 12 were clinically diagnosed with intestinal ischemia. These patients had significantly higher CABA test values (0.52 ABSU +/- 0.04 SEM) than patients without intestinal ischemia (0.31 ABSU +/- 0.02 SEM, p = 0.00023). Only two false-positives and no false-negatives were recorded. This resulted in a sensitivity of 100% and a specificity of 85.7% for the CABA test for these particular samples. The CABA test could be a useful tool for clinicians in the risk stratification of intestinal ischemia.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1097/ta.0b013e31815b846a

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Research works printed but not linked: 11

  1. McCaig, 2006, National hospital ambulatory medical care survey: 2004 emergency department summary., Adv Data, 372, 1
  2. Sreenarasimhaiah, 2003, Diagnosis and management of intestinal ischaemic disorders., BMJ, 326, 1372, 10.1136/bmj.326.7403.1372 · DOI · Paper page
  3. Bar-Or, 2001, Characterization of the Co(2+) and Ni(2+) binding amino-acid residues of the N-terminus of human albumin. An insight into the mechanism of a new assay for myocardial ischemia., Eur J Biochem, 268, 42, 10.1046/j.1432-1327.2001.01846.x · DOI · Paper page
  4. Sadler, 1994, Involvement of a lysine residue in the N-terminal Ni2+ and Cu2+ binding site of serum albumins. Comparison with Co2+, Cd2+ and Al3+., Eur J Biochem, 220, 193, 10.1111/j.1432-1033.1994.tb18614.x · DOI · Paper page
  5. Bar-Or, 2000, A novel assay for cobalt-albumin binding and its potential as a marker for myocardial ischemia-a preliminary report., J Emerg Med, 19, 311, 10.1016/S0736-4679(00)00255-9 · DOI · Paper page
  6. Bar-Or, 2001, Reduced albumin-cobalt binding with transient myocardial ischemia after elective percutaneous transluminal coronary angioplasty: a preliminary comparison to creatine kinase-MB, myoglobin, and troponin I., Am Heart J, 141, 985, 10.1067/mhj.2001.114800 · DOI · Paper page
  7. Bhagavan, 2003, Evaluation of human serum albumin cobalt binding assay for the assessment of myocardial ischemia and myocardial infarction., Clin Chem, 49, 581, 10.1373/49.4.581 · DOI · Paper page
  8. Sinha, 2003, Ischemia modified albumin is a sensitive marker of myocardial ischemia after percutaneous coronary intervention., Circulation, 107, 2403, 10.1161/01.CIR.0000072764.18315.6B · DOI · Paper page
  9. Christenson, 2001, Characteristics of an albumin cobalt binding test for assessment of acute coronary syndrome patients: a multicenter study., Clin Chem, 47, 464, 10.1093/clinchem/47.3.464 · DOI · Paper page
  10. Can, 2006, Evaluation of effects of ischaemia on the albumin cobalt binding (ACB) assay in patients exposed to trauma., Emerg Med J, 23, 537, 10.1136/emj.2005.030486 · DOI
  11. Mallick, 2004, Ischemia-reperfusion injury of the intestine and protective strategies against injury., Dig Dis Sci, 49, 1359, 10.1023/B:DDAS.0000042232.98927.91 · DOI · Paper page

Cited by

See all 47

Metadata

Authors
Polk, J. D., Rael, L. T., Craun, M. L., Mains, C. W., Davis-Merritt, D., & Bar-Or, D.
Venue
Journal of Trauma: Injury, Infection & Critical Care
Published
2008-01
Volume
64
Issue
1
Pages
42-45
ISSN
0022-5282 (ISSN-L)
OpenAlex
W2074851095
Cited by
47
References
1
FWCI
3.56
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.