CoChat

HBOC-201 as an Alternative to Blood Transfusion: Efficacy and Safety Evaluation in a Multicenter Phase III Trial in Elective Orthopedic Surgery

Jahr, Jonathan S., Mackenzie, Colin, Pearce, L Bruce, Pitman, Arkadiy, Greenburg, A Gerson · 2008 · Journal of Trauma: Injury, Infection & Critical Care
Cited by 174

The DOI matches its Crossref record; 21 of the 21 references it cites were found in a registry or an index.

Abstract

BACKGROUND: The ability of hemoglobin based oxygen carrier-201 (HBOC-201) to safely reduce and/or eliminate perioperative transfusion was studied in orthopedic surgery patients. METHODS: A randomized, single-blind, packed red blood cell (PRBC)-controlled, parallel-group multicenter study was conducted. Six hundred eighty-eight patients were randomized to treatment with HBOC-201 (H, n = 350) or PRBC (R, n = 338) at the first transfusion decision. Primary endpoints were transfusion avoidance and blinded assessment [Mann-Whitney estimator (MW)] of safety noninferiority. Groups were compared directly and by paired/matching group analyses predicated on a prospectively defined dichotomy [treatment success (HH) vs. failure (HR)] in the H arm and an equivalently defined dichotomy [</=3 (R3-) vs. >3 (R3+) units PRBC] in the R arm, based on need (moderate vs. high) for additional oxygen carrying capacity. RESULTS: A total of 59.4% of patients in the H arm avoided PRBC transfusion. Adverse events (8.47 vs. 5.88), and serious adverse events (SAEs) (0.35 vs. 0.25) per patient were higher in the H versus R arms (p < 0.001 and p < 0.01) with MW = 0.561 (95 CI 0.528-0.594). HH versus R3- had identical (0.14) serious adverse events/patient and a MW = 0.519 (95% confidence limit 0.481-0.558), whereas the incidence was higher (0.63 vs. 0.47) for HR versus R3+ with a MW = 0.605 (95% confidence limit 0.550-0.662). Age (>80 years), volume overload and undertreatment contributed to this imbalance. CONCLUSION: HBOC-201 eliminated transfusion in the majority of subjects. The between arms (H vs. R) safety analysis was unfavorable and likely related to patient age, volume overload, and undertreatment and was isolated to patients that could not be managed by HBOC-201 alone. However, patients <80 years old with moderate clinical need may safely avoid transfusion when treated with up to 10 units of HBOC-201.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1097/ta.0b013e318173a93f

Cites

21 of 21 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 21 references

Cited by

Metadata

Authors
Jahr, J. S., Mackenzie, C., Pearce, L. B., Pitman, A., & Greenburg, A. G.
Venue
Journal of Trauma: Injury, Infection & Critical Care
Published
2008-06
Volume
64
Issue
6
Pages
1484-1497
ISSN
0022-5282 (ISSN-L)
OpenAlex
W1970057110
Cited by
174
References
21
FWCI
7.38
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.