Are the days of counting seizures numbered?
The DOI matches its Crossref record; 10 of the 10 references it cites were found in a registry or an index.
Abstract
Purpose of review: The estimation of seizure frequency is a cornerstone of clinical management of epilepsy and the evaluation of new therapies. Current estimation approaches are significantly limited by several factors. Comparing patient diaries and objective estimates (through both inpatient video-EEG monitoring of and long-term ambulatory EEG studies) reveal that patients document seizures inaccurately. So far, few practical alternative methods of estimation have been available. Recent findings: We review the systems of counting currently utilized and their limitations, as well as the limitations imposed by problems defining clinical events. Alternative methodologies that permit the volatility of seizure rates to be accommodated, and possible alternative measures of brain excitability will be outlined. Recent developments in technologies around data capture, such as wearable and implantable devices, as well as significant advances in the ability to analyse the large data-sets supplied by these systems have provided a wealth of information. Summary: There are now unprecedented opportunities to utilize and apply these insights in routine clinical management and assessment of therapies. The rapid adoption of long-term, wearable monitoring systems will permit major advances in our understanding of the natural history of epilepsy, and lead to more effective therapies and improved patient safety.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Early Identification of Refractory Epilepsy
Kwan, P., & Brodie, M. J. (2000) · New England Journal of Medicine · doi:10.1056/nejm200002033420503 · Cited by 5,204
Responsive cortical stimulation for the treatment of medically intractable partial epilepsy
Morrell, M. J. (2011) · Neurology · doi:10.1212/wnl.0b013e3182302056 · Cited by 1,282
Long-term treatment with responsive brain stimulation in adults with refractory partial seizures
Bergey, G. K., Morrell, M. J., Mizrahi, E. M., Goldman, A., King-Stephens, D., Nair, D., Srinivasan, S., Jobst, B., Gross, R. E., Shields, D. C., et al. (2015) · Neurology · doi:10.1212/wnl.0000000000001280 · Cited by 634
Boto, E., Meyer, S. S., Shah, V., Alem, O., Knappe, S., Kruger, P., Fromhold, T. M., Lim, M., Glover, P. M., Morris, P. G., et al. (2017) · NeuroImage · doi:10.1016/j.neuroimage.2017.01.034 · Cited by 471
Convulsive seizure detection using a wrist‐worn electrodermal activity and accelerometry biosensor
Poh, M., Loddenkemper, T., Reinsberger, C., Swenson, N. C., Goyal, S., Sabtala, M. C., Madsen, J. R., & Picard, R. W. (2012) · Epilepsia · doi:10.1111/j.1528-1167.2012.03444.x · Cited by 272
Automated seizure detection systems and their effectiveness for each type of seizure
Ulate-Campos, A., Coughlin, F., Gaínza-Lein, M., Fernández, I. S., Pearl, P. L., & Loddenkemper, T. (2016) · Seizure · doi:10.1016/j.seizure.2016.06.008 · Cited by 233
Multicenter clinical assessment of improved wearable multimodal convulsive seizure detectors
Onorati, F., Regalia, G., Caborni, C., Migliorini, M., Bender, D., Poh, M., Frazier, C., Kovitch Thropp, E., Mynatt, E. D., Bidwell, J., et al. (2017) · Epilepsia · doi:10.1111/epi.13899 · Cited by 212
A forward-looking review of seizure prediction
Freestone, D. R., Karoly, P. J., & Cook, M. J. (2017) · Current Opinion in Neurology · doi:10.1097/wco.0000000000000429 · Cited by 169
Self-citationManagement of Drug-Resistant Epilepsy
Nair, D. R. (2016) · Continuum · doi:10.1212/con.0000000000000297 · Cited by 68
Tracking generalized tonic-clonic seizures with a wrist accelerometer linked to an online database
Velez, M., Fisher, R. S., Bartlett, V., & Le, S. (2016) · Seizure · doi:10.1016/j.seizure.2016.04.009 · Cited by 65
Cited by
Regalia, G., Onorati, F., Lai, M., Caborni, C., & Picard, R. W. (2019) · Epilepsy Research · doi:10.1016/j.eplepsyres.2019.02.007 · Cited by 240
“…diaries represent the current standard in outpatient studies, but are unreliable, especially for counting seizures that cause loss of consciousness (Karoly et al, 2018), such as primary generalized tonic-clonic and focal to bilateral tonic-clonic (formerly known as secondarily generalized…”
BackgroundSeizure Cycles in Focal Epilepsy
Leguia, M. G., Andrzejak, R. G., Rummel, C., Fan, J. M., Mirro, E. A., Tcheng, T. K., Rao, V. R., & Baud, M. O. (2021) · JAMA Neurology · doi:10.1001/jamaneurol.2020.5370 · Cited by 185
A new era in electroencephalographic monitoring? Subscalp devices for ultra–long‐term recordings
Duun‐Henriksen, J., Baud, M., Richardson, M. P., Cook, M., Kouvas, G., Heasman, J. M., Friedman, D., Peltola, J., Zibrandtsen, I. C., & Kjaer, T. W. (2020) · Epilepsia · doi:10.1111/epi.16630 · Cited by 183
Self-citationComputer-assisted EEG diagnostic review for idiopathic generalized epilepsy
Clarke, S., Karoly, P. J., Nurse, E., Seneviratne, U., Taylor, J., Knight-Sadler, R., Kerr, R., Moore, B., Hennessy, P., Mendis, D., et al. (2021) · Epilepsy & Behavior · doi:10.1016/j.yebeh.2019.106556 · Cited by 55
Self-citationPalmer, E. E., Howell, K., & Scheffer, I. E. (2021) · Neurotherapeutics · doi:10.1007/s13311-021-01133-3 · Cited by 53
Metadata
- Authors
- Karoly, P., Goldenholz, D. M., & Cook, M.
- Venue
- Current Opinion in Neurology
- Published
- 2018-04
- Volume
- 31
- Issue
- 2
- Pages
- 162-168
- ISSN
- 1350-7540 (ISSN-L)
- 1473-6551
- OpenAlex
- W2793512965
- Cited by
- 50
- References
- 10
- FWCI
- 4.68
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.