Student or educator? Sign up with your school email and get 6 months of Pro free.
CoChat
Cited by 204

The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.

Detecting Epileptic Seizures in Long-term Human EEG: A New Approach to Automatic Online and Real-Time Detection and Classification of Polymorphic Seizure Patterns

Meier, Ralph, Dittrich, Heike, Schulze-Bonhage, Andreas, Aertsen, Ad · 2008 · Journal of Clinical Neurophysiology

Abstract

Epileptic seizures can cause a variety of temporary changes in perception and behavior. In the human EEG they are reflected by multiple ictal patterns, where epileptic seizures typically become apparent as characteristic, usually rhythmic signals, often coinciding with or even preceding the earliest observable changes in behavior. Their detection at the earliest observable onset of ictal patterns in the EEG can, thus, be used to start more-detailed diagnostic procedures during seizures and to differentiate epileptic seizures from other conditions with seizure-like symptoms. Recently, warning and intervention systems triggered by the detection of ictal EEG patterns have attracted increasing interest. Since the workload involved in the detection of seizures by human experts is quite formidable, several attempts have been made to develop automatic seizure detection systems. So far, however, none of these found widespread application. Here, we present a novel procedure for generic, online, and real-time automatic detection of multimorphologic ictal-patterns in the human long-term EEG and its validation in continuous, routine clinical EEG recordings from 57 patients with a duration of approximately 43 hours and additional 1,360 hours of seizure-free EEG data for the estimation of the false alarm rates. We analyzed 91 seizures (37 focal, 54 secondarily generalized) representing the six most common ictal morphologies (alpha, beta, theta, and delta- rhythmic activity, amplitude depression, and polyspikes). We found that taking the seizure morphology into account plays a crucial role in increasing the detection performance of the system. Moreover, besides enabling a reliable (mean false alarm rate<0.5/h, for specific ictal morphologies<0.25/h), early and accurate detection (average correct detection rate>96%) within the first few seconds of ictal patterns in the EEG, this procedure facilitates the automatic categorization of the prevalent seizure morphologies without the necessity to adapt the proposed system to specific patients.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1097/wnp.0b013e3181775993

Cites

3 of 3 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 204

Metadata

Authors
Meier, R., Dittrich, H., Schulze-Bonhage, A., & Aertsen, A.
Venue
Journal of Clinical Neurophysiology
Published
2008-06
Volume
25
Issue
3
Pages
119-131
ISSN
0736-0258 (ISSN-L)
OpenAlex
W2117504492
Cited by
204
References
3
FWCI
4.38
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Detecting Epileptic Seizures in Long-term Human EEG: A New Approach to Automatic Online and Real-Time Detection and Classification of Polymorphic Seizure Patterns. https://app.cochat.ai/papers/10.1097/wnp.0b013e3181775993
The paper
Meier, R., Dittrich, H., Schulze-Bonhage, A., & Aertsen, A. (2008). Detecting Epileptic Seizures in Long-term Human EEG: A New Approach to Automatic Online and Real-Time Detection and Classification of Polymorphic Seizure Patterns. Journal of Clinical Neurophysiology. https://doi.org/10.1097/wnp.0b013e3181775993

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.